AS 4118.1.7-1996

Current
Current

The latest, up-to-date edition.

Fire sprinkler systems Components - Alarm valves (dry) (Reconfirmed 2013)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-05-1996

Preview

This Standard has been reconfirmed. To view or download the Reconfirmation Notice please click here.

1 - AS 4118.1.7:1996 FIRE SPRINKLER SYSTEMS - COMPONENTS - ALARM VALVES (DRY)
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 - SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 NEW DESIGNS AND INNOVATIONS
6 - 1.3 DEEMED TO SATISFY
6 - 1.4 REFERENCED DOCUMENTS
7 - 1.5 DEFINITIONS
7 - 1.5.1 Anti- reseat latch-
7 - 1.5.2 Automatic drain valve
7 - 1.5.3 Dry alarm valve
7 - 1.5.4 Regulatory authority-
8 - SECTION 2 - REQUIREMENTS
8 - 2.1 NOMINALSIZE
8 - 2.2 CONNECTIONS
8 - 2.3 RATED WORKINGPRESSURES
8 - 2.4 BODIES AND COVERS
8 - 2.5 STRENGTH
9 - 2.6 DRAINS
9 - 2.7 ACCESS FOR MAINTENANCE
9 - 2.8 CONNECTIONS
9 - 2.9 COMPONENTS
11 - 2.10 NON- METALLIC COMPONENTS (excluding gaskets and seals)
11 - 2.11 SEALING ASSEMBLY ELEMENTS
12 - 2.12 CLEARANCES
12 - 2.13 OPERATIONAL PERFORMANCE
13 - 2.14 HYDRAULIC FRICTION LOSS
13 - TABLE 1
13 - REQUIRED FLOW RATES FOR PRESSURE
13 - DROP DETERMINATION
13 - 2. 15 LEAKAGE
14 - 2.16 ENDURANCE TEST
15 - SECTION 3 - TEST METHODS
15 - 3.1 SPRING AND DIAPHRAGM TEST
15 - 3.2 AIR-OVEN AGEING FOR NON-METALLIC COMPONENTS (excluding gaskets and seals)
15 - 3.3 WARM WATER AGEING FOR NON-METALLIC COMPONENTS (excluding gaskets and seals)
16 - 3.4 SEALING ELEMENT TEST
16 - 3.5 HYDRAULIC FRICTION LOSS TEST AND ENDURANCE TEST
16 - 3.6 VALVE LEAKAGE AND DEFORMATION TEST
17 - 3.7 BODY STRENGTH TEST
17 - 3.8 OPERATIONAL TEST
18 - 3.9 ANTI-RESEATING TEST
18 - 3.10 FIRE EXPOSURE TEST
19 - 3.11 QUICK RELEASE TEST
23 - SECTION 4 - MARKING
23 - 4.1 GENERAL
23 - 4.2 BODY MARKINGS
23 - SECTION 5 - INSTRUCTION CHARTS

Specifies the requirements for the construction of dry alarm valves for use in fire sprinkler systems.

This Standard specifies requirements for the construction and performance of alarm valves (dry) for fire sprinkler systems.

Committee
FP/4
DocumentType
Standard
ISBN
0 7337 0230 9
Pages
18
ProductNote
Reconfirmed 10-07-2013
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS 4118.1.7-1996.Reconfirmed 2013. First published as AS 4118.1.7-1996.

AS 3500.0-1990 National Plumbing and Drainage Code Glossary of terms
AS 1683.11-2001 Methods of test for elastomers Tension testing of vulcanized or thermoplastic rubber (Reconfirmed 2018)
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
AS 1683.11-1990 Methods of test for elastomers Tension testing of vulcanized rubber
AS 2118.1-1995 Automatic fire sprinkler systems - Standard
AS 1628-1999 Water supply - Metallic gate, globe and non-return valves
AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)

AS 2118.1:2017 Automatic fire sprinkler systems General systems
HB 147-2000 Sprinklers Simplified
AS 4041-2006 Pressure piping (Reconfirmed 2016)
AS 2118.2-1995 Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers)
AS 2118.6-2012 Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings
AS 2118.1-1995 Automatic fire sprinkler systems - Standard
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS/NZS 3500.1:2003 Plumbing and drainage Water services
AS 2118.5-2008 Automatic fire sprinkler systems Home fire sprinkler systems (Reconfirmed 2020)

View more information
US$26.49
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.