An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Performance of electrical appliances - Airconditioners and heat pumps Non-ducted airconditioners and heat pumps - Testing and rating for performance
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

08-05-1998

Preview

Specifies the testing Standards for room airconditioners. This Standard is technically equivalent to and reproduced from ISO 5151:1994.

1.1 This International Standard specifies the standard conditions on which the ratings of single-package and split-system non-ducted air conditioners employing air- and water-cooled condensers and heat pumps employing air-cooled condensers are based, and the test methods to be applied for determination of the various ratings. This International Standard is limited to systems utilizing a single refrigeration circuit and having one evaporator and one condenser.NOTE 1 For the purposes of this International Standard, the term "equipment" will be used to mean "non-ducted air conditioners and/or non-ducted heat pumps".1.2 This International Standard also specifies the test conditions and the corresponding test procedures for determining various performance characteristics of these non-ducted air conditioners and heat pumps.1.3 It does not apply to the testing and rating of:a) water-source heat pumps;b) multiple split-system1)air conditioners and heat pumps;c) units designed for use with additional ducting; ord) mobile (windowless) units having a condenser exhaust duct.1.4 Clause 4 of this International Standard covers the rating and testing conditions for non-ducted air conditioners and heal pumps when used for cooling.1.5 Clause 5 of this International Standard covers the rating and testing conditions for non-ducted air conditioners and heat pumps when used for heating. The means for heating may be the heat pump refrigeration cycle or electrical resistance.1.6 Annex A establishes testing procedures. Annex B describes the test facilities for the calorimeter method. Annex C provides formulae for the calculation of heating and cooling capacities. Annex D describes instruments which can be used in making measurements, and annex E describes methods for measuring air-flow. Annex F describes the outdoor air-enthalpy test method. Annex G gives a list of symbols used in the annexes.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 1976 7
Pages
52
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
ISO 5151:1994 Identical

Draft Amendment 2 see DR 01398 CP First published in Australia as AS B210-1966.Revised and redesignated AS 1861-1976.Second edition 1981.Revised and redesignated AS 1861.1-1988.Jointly revised and redesignated AS/NZS 3823.1.1:1998. First published in Australia as AS B210-1966. Revised and redesignated AS 1861-1976. Second edition 1981. Revised and redesignated AS 1861.1-1988. Jointly revised and redesignated AS/NZS 3823.1.1:1998.

AS/NZS 1677.1:1998 Refrigerating systems - Refrigerant classification

AS/NZS 4692.1:2005 Electric water heaters Energy consumption, performance and general requirements (Reconfirmed 2016)
AS/NZS 3823.2:2011 Performance of electrical appliances Air conditioners and heat pumps
AS/NZS 3823.2:2000 Performance of household electrical appliances - Room airconditioners - Energy labelling requirements
AS/NZS 3823.1.4:2012 Performance of electrical appliances - Airconditioners and heat pumps Multiple split-system airconditioners and air-to-air heat pumps - Testing and rating for performance (ISO 15042:2011, MOD)
AS/NZS 3823.2:2005 Performance of electrical appliances - Airconditioners and heat pumps - Energy labelling and minimum energy performance standard (MEPS) requirements
AS/NZS 3823.3:2001 Performance of electrical appliances - Airconditioners and heat pumps - Calculation of performance for minimum energy performance standard (MEPS) requirements
AS/NZS 3823.2:2003 Performance of electrical appliances - Airconditioners and heat pumps - Energy labelling and minimum energy performance standard (MEPS) requirements
AS/NZS 3823.3:2002 Performance of electrical appliances - Airconditioners and heat pumps Calculation of performance for minimum energy performance standard (MEPS) requirements
AS/NZS 3823.2:2001 Performance of electrical appliances - Airconditioners and heat pumps - Energy labelling and minimum energy performance standard (MEPS) requirements
AS/NZS 3823.2:1998 Performance of household electrical appliances - Room airconditioners - Energy labelling requirements
AS 4755.3.1-2008 Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for airconditioners
AS/NZS 3823.2:2009 Performance of electrical appliances - Air conditioners and heat pumps

View more information
US$82.57
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.