• There are no items in your cart

AS/NZS 4695.112:1996

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-28-2023

Language(s)

English

Published date

05-05-1996

1 - AS/NZS 4695.112:1996 FIRE HAZARD TESTING OF ELECTROTECHNICAL PRODUCTS - METHOD FOR DETERMINING THE COMPARATIVE AND THE...
4 - PREFACE
5 - CONTENTS
7 - 1. Scope
7 - 2. Definitions
7 - 2.1 Tracking
7 - 2.2 Electrical erosion
7 - 2.3 Comparative tracking index (CTI)
7 - 2.4 Proof tracking index (PTI)
8 - 3. Test specimen
8 - 4. Conditioning
8 - 5. Test apparatus
8 - 5.1 Electrodes
8 - 5.2 Test circuit
9 - 5.3 Dropping device
9 - 5.4 Test solutions
9 - 6. Procedure
9 - 6.1 General
10 - 6.2 Determination of the CTI
10 - 6.3 Proof tracking test
11 - 6.4 Determination of erosion
11 - 7. Report

Describes a method of test intended to indicate the relative resistance of solid electrical insulating materials to tracking for voltages up to 600 V when the surface is exposed, under electric stress, to water with the addition of contaminants. This Standard is identical with and has been reproduced from IEC 112:1979.

This method of test indicates the relative resistance of solid electrical insulating materials to tracking for voltages up to 600 V when the surface is exposed under electric stress to water with the addition of contaminants.Tracking may occur during this test when voltage is applied between a defined electrode arrangement on the surface of a material and drops of electrolyte are applied between them at defined intervals of time. The number of drops needed to cause failure increases with the reduction of the applied voltage and, below a critical value, tracking ceases to occur.Materials which do not track at the highest test voltage may erode differently. The depth of erosion can be measured. Some materials may ignite during the test.Notes 1. - The grading of materials reached by this method may possibly differ from that obtained by other testing methods for assessing tracking resistance, for example tests based on the use of high voltage, low-current discharges. This test method provides good resolution between materials with relatively poor tracking resistance. It lacks resolution for materials normally required for outdoor use for which the test method in IEC Publication 587: Test Method for Evaluating Resistance to Tracking and Erosion of Electrical Insulating Materials Used under Severe Ambient Conditions, should be used.2 . - The test results as such cannot be used directly for the evaluation of safe creepage distances when designing electrical apparatus.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 0375 5
Pages
7
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60112:1979 Identical

First published in Australia as part of AS 2420-1980.Second edition 1983.Third edition 1987.First published in New Zealand as part of AS 2420-1987.Jointly revised and redesignated in part as AS/NZS 4695.112:1996. First published in Australia as part of AS 2420-1980. Second edition 1983. Third edition 1987. First published in New Zealand as part of AS 2420-1987. Jointly revised and redesignated in part as AS/NZS 4695.112:1996.

AS/NZS 60079.7:2002 Electrical apparatus for explosive gas atmospheres Increased safety 'e'
AS/NZS 3100:1997 Approval and test specification - General requirements for electrical equipment
AS/NZS 60928:2000 Auxiliaries for lamps - A.C. supplied electronic ballasts for tubular fluorescent lamps - General and safety requirements (IEC 60928:1995 MOD)
AS/NZS 61058.1:2008 Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD)
AS/NZS 3123:2000 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application
AS/NZS 3109.1:1996 Approval and test specification - Appliance couplers for household and similar general purposes General requirements
AS/NZS 60922:1998 Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - General and safety requirements
AS/NZS 61558.2.6:2001 Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)
AS/NZS 3350.1:2000 Safety of household and similar electrical appliances General requirements (IEC 60335-1:1994 MOD)
AS/NZS 3947.6.1:2001 Low-voltage switchgear and controlgear Multiple Function equipment - Automatic transfer switching equipment
AS/NZS 61535.1(INT):2001 Installation couplers General requirements
AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS/NZS 3131:2001 Approval and test specification - Plugs and socket-outlets for stationary appliances
AS/NZS 3947.2:2002 Low-voltage switchgear and controlgear Circuit-breakers
AS 3947.2-1997 Low-voltage switchgear and controlgear - Circuit-breakers
AS/NZS 61058.1:2002 Switches for appliances General requirements (IEC 61058.1:2000 MOD)
AS/NZS 60065:2003 Audio, video and similar electronic apparatus - Safety requirements (IEC 60065:2001, MOD)
AS/NZS 61535.1:2003 Installation couplers General requirements
AS/NZS 60079.1:2005 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd'
AS/NZS 60745.1:2003 Hand-held motor-operated electric tools - Safety General requirements (IEC 60745-1:2001, MOD)
AS/NZS 3947.1:1998 Low-voltage switchgear and controlgear General rules
AS/NZS 60079.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd'
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS/NZS 61558.1:2000 Safety of power transformers, power supply units and similar General requirements and tests (IEC 61558-1 Ed 1.1, MOD)
AS/NZS 60998.1:1998 Connecting devices for low voltage circuits for household and similar purposes General requirements
AS/NZS 4871.3:2002 Electrical equipment for coal mines, for use underground Substations
AS/NZS 60598.1:1998 Luminaires General requirements and tests
AS/NZS 60079.2:2002 Electrical apparatus for explosive gas atmospheres Pressurized enclosures 'p'
AS/NZS 60079.15:2006 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus
AS/NZS 3350.1:2002 Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD)
AS/NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD)
AS/NZS 3947.4.1:2001 Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS/NZS 3947.1:2001 Low-voltage switchgear and controlgear General rules
AS/NZS 60079.11:2000 Electrical apparatus for explosive gas atmospheres Intrinsic safety 'i'
AS 60269.2.1-2005 Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses
AS/NZS 4871.1:2002 Electrical equipment for coal mines, for use underground General requirements

View more information
US$15.94
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.