1 - AS/NZS 4847.1(Int):2008 SELF-BALLASTED LAMPS FOR GENERAL LIGHTING SERVICES - TEST METHODS-ENERGY PERFORMANCE
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 REFERENCED DOCUMENTS
8 - 3 DEFINITIONS
8 - 3.1 Beam angle (beam spread)
8 - 3.2 Efficacy
8 - 3.3 Final luminous flux
8 - 3.4 Initial values
8 - 3.5 Lamp failure
8 - 3.6 Lamp life
8 - 3.7 Lumen maintenance
8 - 3.8 Median lamp life
8 - 3.9 New lamp
8 - 3.10 Power factor
8 - 3.11 Rated values
8 - 3.12 Run-up time
9 - 3.13 Self-ballasted compact fluorescent lamp
9 - 3.14 Stabilization time
9 - 3.15 Starting time
9 - 3.16 Test voltage
9 - 3.17 Colour
9 - 3.18 Type
9 - 3.19 Type test
9 - 3.20 Type test sample
9 - 4 LAMP REQUIREMENTS
9 - 4.1 General conditions
9 - 4.2 Starting time
10 - 4.3 Run-up time
10 - 4.4 Low temperature starting
10 - 4.5 Lamp wattage
10 - 4.6 Power factor
10 - 4.7 Luminous flux and initial efficacy
10 - 4.8 Colour and colour rendering index
10 - 4.9 Switching withstand
10 - 4.10 Lamp life
10 - 4.11 Lumen maintenance
10 - 4.12 Light distribution ratio
10 - 4.13 Harmonics and EMC
10 - 4.14 Mercury content determination
10 - 4.15 Safety requirements
10 - 5 SAMPLING
12 - APPENDIX A - GENERAL CONDITIONS FOR MEASUREMENT OF PHOTOMETRIC AND ELECTRICAL CHARACTERISTICS
12 - A1 AIR MOVEMENT AND TEMPERATURE
12 - A1.1 Test room
12 - A1.2 Ageing room
12 - A2 SUPPLY
12 - A3 POSITION OF LAMP
12 - A4 LAMP STABILIZATION
13 - A5 LAMP AGEING
13 - A6 MEASUREMENT EQUIPMENT AND ACCURACY
13 - A6.1 Supply voltage for test
13 - A6.2 Supply voltage for ageing
13 - A7 ELECTRICAL MEASUREMENT
13 - A8 LUMINOUS FLUX MEASUREMENT
13 - A8.1 Measurement equipment for tests
13 - A8.2 Integrating sphere
14 - A8.3 Goniophotometer (distribution photometer)
14 - A8.4 Spectroradiometer
14 - A8.5 Colorimeter
14 - A9 TIME MEASUREMENT
15 - APPENDIX B - TEST FOR STARTING TIME
15 - B1 GENERAL
15 - B2 TEST CONDITIONS
16 - B3 TEST PROCEDURE
16 - B4 CALCULATIONS
18 - APPENDIX C - TEST FOR RUN-UP TIME
18 - C1 GENERAL
18 - C2 TEST CONDITIONS
18 - C3 PREPARATION OF APPARATUS
19 - C4 TEST PROCEDURE
19 - C5 CALCULATIONS
20 - APPENDIX D - MEASUREMENT OF INITIAL LUMINOUS FLUX, EFFICACY AND LUMEN MAINTENANCE
20 - D1 GENERAL
20 - D2 TEST CONDITIONS AND PREPARATION OF APPARATUS
20 - D2.1 All methods
20 - D2.2 Method A1 (Integrating sphere measurement: spectral photometry) andMethod A2 (Integrating sphere measurement: integrating method)
20 - D2.3 Method B (Goniophotometer: distribution photometer)
21 - D3 TEST PROCEDURE
21 - D3.1 All methods
21 - D3.2 Method A1 (Integrating sphere measurement: spectral photometry) and MethodA2 (Integrating sphere measurement: integrating method)
21 - D3.3 Method B (Goniophotometer: distribution photometer)
21 - D3.4 Calculations
23 - D4 INITIAL EFFICACY TEST
23 - D4.1 Test procedure
23 - D4.2 Calculations
23 - D5 LUMEN MAINTENANCE AND MAINTAINED EFFICACY TESTS
24 - APPENDIX E - TEST FOR LOW TEMPERATURE STARTING TIME
24 - E1 GENERAL
24 - E2 TEST CONDITIONS
24 - E3 TEST PROCEDURE
25 - APPENDIX F - TEST FOR SWITCHING WITHSTAND
26 - APPENDIX G - TEST FOR LAMP LIFE
27 - APPENDIX H - TEST FOR LIGHT DISTRIBUTION
28 - APPENDIX I - TEST REPORT
29 - APPENDIX J - BIBLIOGRAPHY

Specifies the test methods and conditions for self-ballasted compact fluorescent lamps (CFLs) and other gas-discharge lamps with integrated means for controlling starting and stable operation that are intended for domestic and similar general lighting purposes.

This Interim Standard specifies the test methods and conditions for self-ballasted compact fluorescent lamps (CFLs) and other gas-discharge lamps with integrated means for controlling starting and stable operation that are intended for domestic and similar general lighting purposes.This Interim Standard applies to self-ballasted lamps of all voltages and wattages irrespective of the type of lamp cap.The requirements in this Interim Standard relate only to type testing and are in addition to the safety requirements that are specified in AS/NZS 60968.

CommentClosesDate
03-28-2010
Committee
EL-041
DocumentType
Standard
ISBN
0 7337 8601 4
Pages
23
PublisherName
Standards Australia
Status
Superseded
SupersededBy

First published as AS/NZS:4847.1(Int):2008.

AS/NZS 4782.3(INT):2006 Double-capped fluorescent lamps - Performance specifications Procedure for quantitative analysis of mercury present in fluorescent lamps
AS/NZS 61000.3.2:2007 Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current (16 A per phase) (IEC 61000-3-2, Ed. 3.0 (2005) MOD)
AS/NZS 60968:2001 Self ballasted lamps for general lighting services - Safety requirements (IEC 60968:1988, MOD) (Reconfirmed 2013)
AS/NZS 60969:2001 Self ballasted lamps for general lighting services - Performance requirements (Reconfirmed 2013)
AS/NZS 4782.1:2004 Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016)

AS/NZS 4847.2(INT):2008 Self-ballasted lamps for general lighting services Minimum Energy Performance Standards (MEPS) requirements

View more information
US$69.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.