• There are no items in your cart

AS/NZS 4965.1:2008

Current

Current

The latest, up-to-date edition.

Performance of close control airconditioners Testing for rating (Reconfirmed 2020)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-14-2008

Preview

1 - AS/NZS 4965.1:2008 PERFORMANCE OF CLOSE CONTROL AIRCONDITIONERS - TESTING FOR RATING
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 3 REFERENCED DOCUMENTS
6 - 4 DEFINITIONS
7 - 4.1 Close control airconditioner
7 - 4.2 Cooling energy efficiency ratio (EER)
7 - 4.3 Effective power input (PE)
7 - 4.4 Full load operation
7 - 4.5 Gross sensible cooling capacity
7 - 4.6 Gross total cooling capacity
7 - 4.7 Indoor discharge airflow
7 - 4.8 Indoor intake airflow
7 - 4.9 Latent capacity-Room dehumidifying capacity
7 - 4.10 Net sensible cooling capacity
7 - 4.11 Net total cooling capacity
7 - 4.12 Outdoor discharge airflow
7 - 4.13 Outdoor intake airflow
7 - 4.14 Rated frequency(ies)
8 - 4.15 Rated voltage(s)
8 - 4.16 Sensible energy efficiency ratio (EERS)
8 - 4.17 Sensible heat ratio
8 - 4.18 Shall
8 - 4.19 Should
8 - 4.20 Standard air
8 - 5 COOLING TESTS
8 - 5.1 Cooling capacity ratings
8 - 5.1.1 General conditions
8 - 5.1.2 Temperature conditions
8 - 5.1.3 Airflow conditions
9 - 5.1.4 Test conditions
9 - 6 TEST METHODS AND UNCERTAINTY OF MEASUREMENT
9 - 6.1 Test methods
10 - 6.2 Uncertainty of measurement
10 - 6.3 Variations in individual readings
10 - 6.4 Test tolerances
11 - 6.5 Standby power and crankcase heaters
11 - 6.5.1 General
11 - 6.5.2 Off mode
12 - 6.5.3 Passive standby mode
12 - 6.5.4 Delay start mode
12 - 6.5.5 Crankcase heaters
12 - 6.6 Testing airconditioners with variable output compressors
13 - 7 TEST RESULTS
13 - 7.1 Capacity calculations
13 - 7.1.1 General
13 - 7.1.2 Adjustments
13 - 7.2 Data to be recorded
14 - 7.3 Test report
14 - 7.3.1 General information
14 - 7.3.2 Additional information
14 - 7.3.3 Rating test results
16 - 8 PUBLICATION OF RATINGS
16 - 8.1 Standard ratings
16 - 8.2 Other ratings
17 - APPENDIX A - TEST PROCEDURES
17 - A1 GENERAL TEST ROOM REQUIREMENTS
17 - A2 EQUIPMENT INSTALLATION
17 - A3 ELECTRICAL SUPPLY REQUIREMENTS
18 - APPENDIX B - CALORIMETER TEST METHOD
18 - B1 GENERAL
23 - B2 CALIBRATED ROOM-TYPE CALORIMETER
24 - B3 BALANCED AMBIENT ROOM-TYPE CALORIMETER
25 - B4 CALORIMETER AND AUXILIARY EQUIPMENT FOR WATER-COOLED CONDENSER TESTS
26 - APPENDIX C - HEATING AND COOLING CAPACITY CALCULATIONS
26 - C1 COOLING CAPACITY CALCULATIONS (CALORIMETER METHOD)
28 - C2 COOLING CAPACITY CALCULATIONS (AIR-ENTHALPY METHOD)
30 - APPENDIX D - AIRFLOW MEASUREMENT
30 - D1 AIRFLOW DETERMINATION
30 - D2 NOZZLES
31 - D3 APPARATUS FOR ROOM DISCHARGE AIRFLOW MEASUREMENTS
32 - D4 INDOOR-SIDE DISCHARGE AIRFLOW MEASUREMENT
33 - D5 VENTILATION, EXHAUST AND LEAKAGE AIRFLOW MEASUREMENTS
33 - D6 TEST APPARATUS CALIBRATION (AIR-ENTHALPY METHOD)
34 - APPENDIX E - REFRIGERANT ENTHALPY TEST METHOD
34 - E1 GENERAL DESCRIPTION
34 - E2 REFRIGERANT FLOW METHOD
34 - E3 REFRIGERANT TEMPERATURE AND PRESSURE MEASUREMENTS
35 - E4 CALCULATION COOLING CAPACITIES
36 - APPENDIX F - LIST OF SYMBOLS

Specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied for determining the capacity and efficiency ratings.

This Standard specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied to determine the capacity and efficiency ratings. This Standard covers equipment utilizing a single or multiple refrigerated direct expansion (DX) system designed to control and monitor temperature and humidity and may include supplementary conditioning equipment.Appendix A establishes testing procedures. Appendix B describes the test facilities required for the calorimeter method. Appendix C provides formulae for calculating heating and cooling capacities. Appendix D describes methods for measuring airflow. Appendix E describes the refrigerant enthalpy test method. Appendix F lists the symbols used in this Standard.This Standard does not cover the determination of seasonal efficiencies, which may be required in some countries.

Committee
EL-015
DocumentType
Standard
ISBN
0 7337 8938 2
Pages
32
ProductNote
Reconfirmed 18/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 18/09/2020
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS/NZS 4965.1:2008.
Reconfirmed 2020. First published as AS/NZS 4965.1:2008.

AS/NZS 62301:2005 Household electrical appliances - Measurement of standby power (IEC 62301, Ed. 1.0 (2005) MOD)

AS/NZS 3823.2:2013 Performance of electrical appliances - Air conditioners and heat pumps Energy labelling and minimum energy performance standards (MEPS) requirements
AS/NZS 4965.2:2008 Performance of close control airconditioners Minimum energy performance standard (MEPS) requirements (Reconfirmed 2020)

View more information
US$82.57
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.