• There are no items in your cart

AS/NZS 60598.2.6:1998

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Luminaires Particular requirements - Luminaires with built-in transformers or convertors for filament lamps (Reconfirmed 2013)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

01-20-2022

Language(s)

English

Published date

03-05-1998

1 - AS/NZS 60598.2.6:1998 LUMINAIRES - PARTICULAR REQUIREMENTS - LUMINAIRES WITH BUILT-IN TRANSFORMERS OR CONVERTORS FOR FILAMENT
4 - PREFACE
5 - CONTENTS
7 - 6.1 Scope
7 - 6.1.1 Normative references
7 - 6.2 General test requirements
8 - 6.3 Definitions
8 - 6.3.1 input winding (of the transformer)
8 - 6.3.2 output winding (of the transformer)
8 - 6.3.3 nominal supply voltage (of the transformer)
8 - 6.3.4 nominal supply voltage range (of the transformer)
8 - 6.3.5 nominal output current (of the transformer)
8 - 6.3.6 nominal output voltage (of the transformer)
8 - 6.3.7 nominal output VA (of the transformer)
8 - 6.4 Classification of luminaires
8 - 6.5 Marking
9 - 6.6 Construction
10 - 6.7 Creepage distances and clearances
10 - 6.8 Provision for earthing
11 - 6.9 Terminals
11 - 6.10 External and internal wiring
11 - 6.11 Protection against electric shock
11 - 6.12 Endurance tests and thermal tests
11 - 6.13 Resistance to dust and moisture
12 - 6.14 Insulation resistance and electric strength
12 - 6.15 Resistance to heat, fire and tracking
13 - Annex A - Examples of construction
14 - ANNEX ZZ - VARIATIONS TO IEC 598-2-6:1994 FOR AUSTRALIAN AND NEW ZEALAND CONDITIONS
14 - ZZ1 INTRODUCTION
14 - ZZ2 VARIATIONS

Specifies minimum safety requirements for luminaires with built-in transformers for filament lamps with supply voltages and output voltages not exceeding 1000 V. This Part is to be read in conjunction with AS/NZS 60598.1:1998. This Standard is technically equivalent to and has been reproduced from IEC 60598-2-6:1994 and IEC 60598-2-6:1994/Amd. 1:1996.

This section of IEC 598-2 specifies requirements for luminaire with built-in transformers for filament lamps, with supply voltages and output voltages not exceeding:- 1 000 V for class I and class II luminaires and- 250 V for class 0 luminaires.It is to be read in conjunction with those sections of IEC 598-1 to which reference is made.This section does not apply to class Ill luminaires.It is not necessary to use "Safety extra low voltage" (SELV) transformers to comply with the requirements of this section. However, such transformers may satisfy the functional requirements of this section.

Committee
EL-041
DocumentType
Standard
ISBN
0 7337 1748 9
Pages
10
ProductNote
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Standards Relationship
IEC 60598-2-6:1994/AMD1:1996 Identical
IEC 60598-2-6:1994 Identical

First published as AS/NZS 60598.2.6:1998.Reconfirmed 2013. First published as AS/NZS 60598.2.6:1998.

AS/NZS 60598.1:1998 Luminaires General requirements and tests
AS/NZS 3108:1994 Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers
AS 1104-1978 Informative symbols for use on electrical and electronic equipment

AS/NZS IEC 61347.2.13:2013 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (IEC 61347-2-13, Ed.1.0 (2006) MOD)
AS/NZS 61347.2.2:2004 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2:2000 MOD)
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 61347.2.2:2007 Lamp controlgear Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps (IEC 61347-2-2, Ed. 1.2 (2006) MOD)
AS/NZS 60598.1:2013 Luminaires General requirements and tests (IEC 60598-1, Ed. 7.0 (2008) MOD)
AS/NZS 60598.2.25:2001 Luminaires Particular requirements - Luminaires for use in clinical areas of hospitals and health care buildings (IEC 60598.2.25:1994, MOD) (Reconfirmed 2013)
AS/NZS 61046:2001 Auxiliaries for lamps - D.C. or A.C. supplied electronic step-down convertors for filament lamps - General and safety requirements (IEC 61046:1993, MOD)
AS/NZS 60079.15:2011 Explosive atmospheres Equipment protection by type of protection 'n'
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 4782.1:2004 Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016)

View more information
US$27.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.