• There are no items in your cart

AS/NZS 61558.2.23:2001

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Safety of power transformers, power supply units and similar devices Particular requirements for transformers for construction sites (IEC 61558-2-23:2000, MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-24-2021

Language(s)

English

Published date

11-12-2001

Preview

1 - AS/NZS 61558.2.23:2001 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR DEVICES - PARTICULAR REQUIREMENTS FOR ...
4 - CONTENTS
7 - PREFACE
9 - 1 Scope
10 - 2 Normative references
10 - 3 Definitions
10 - 4 General requirements
10 - 5 General notes on tests
11 - 6 Ratings
12 - 7 Classification
12 - 8 Marking and other information
14 - 9 Protection against accessibility to hazardous live parts
14 - 10 Change of input voltage setting
15 - 11 Output voltage and output current under load
15 - 12 No-load output voltage
16 - 13 Short-circuit voltage
17 - 14 Heating
17 - 15 Short-circuit and overload protection
17 - 16 Mechanical strength
18 - 17 Protection against harmful ingress of dust, solid objects and moisture
18 - 18 Insulation resistance and electric strength
18 - 19 Construction
21 - 20 Components
21 - 21 Internal wiring
21 - 22 Supply connection and other external flexible cables or cords
21 - 23 Terminals for external conductors
21 - 24 Provision for protective earthing
21 - 25 Screws and connections
21 - 26 Creepage distances, clearances and distances through insulation
21 - 27 Resistance to heat, abnormal heat, fire and tracking
21 - 28 Resistance to rusting

Specifies general safety requirements for approval and test purposes for transformers for construction sites. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-23:2000.

Replacement:This International Standard deals with all aspects of safety such as electrical, thermal and mechanical.This part of IEC 61558 AS/NZS 61558 applies to stationary or portable single-phase or poly-phase air-cooled (natural or forced) independent or associated, isolating or safety isolating transformers intended for use on construction sites, having a rated supply voltage not exceeding 1 000 V a.c., and a rated frequency not exceeding 500 Hz.The rated output should not exceed: 25 kVA for single-phase transformers; 40 kVA for poly-phase transformers.Isolating transformers for construction sites should have a no-load output voltage and a rated output voltage exceeding 50 V a.c. and not exceeding 250 V a.c.Safety isolating transformers for construction sites should have a no-load output voltage and a rated output voltage not exceeding 50 V a.c.NOTE This standard is applicable to transformers for the supply of electricity in locations as specified in IEC 60364-7-704. The latter also specifies the protection by using an earthed midpoint or starpoint of the output winding.Transformers for construction sites are to be used when required by the installation rules or by the appliance specification for protection purposes.When the transformers are incorporated into low-voltage switchgear and controlgear assemblies for construction sites as specified in IEC 60439-4, the additional requirements of IEC 60439-4 will apply to the assembly.This standard is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated.NOTE 1 For transformers filled with liquid dielectric or pulverized material, such as sand, additional requirements are under consideration.NOTE 2 Attention is drawn to the fact that for transformers intended to be used in tropical countries, special requirements may be necessary; for the purposes of this standard, Australia and New Zealand are not considered to be tropical; in locations where special environmental conditions prevail, particular requirements may be necessary.This standard also applies to transformers incorporating electronic circuits. This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 4426 5
Pages
16
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS/NZS 61558.2.23:2001.

AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS 2703-2008 Vehicle loop detector sensors
AS/NZS 4836:2011 Safe working on or near low-voltage electrical installations and equipment
AS 2865-2009 Confined spaces
AS/NZS 3439.4:2009 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS 2144:2014 Traffic signal lanterns
AS/NZS 3105:2014 Approval and test specification - Electrical portable outlet devices
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)

View more information
US$65.36
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.