Electrical apparatus for the detection and measurement of flammable gases Performance requirements for group II apparatus indicating a volume fraction up to 100% lower explosive limit

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-29-2023

Language(s)

English

Published date

02-23-2000

1 - AS/NZS 61779.4:2000 ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PERFORMANCE REQUIREMENTS FOR...
4 - PREFACE
5 - CONTENTS
7 - 1 Scope
7 - 2 Definitions
7 - 3 General requirements
7 - 4 Performance requirements
7 - 4.1 General
7 - 4.2 Unpowered storage
8 - 4.3 Calibration curve (not applicable to alarm-only apparatus)
8 - 4.3.1 Calibration curve
8 - 4.3.2 Response to gases other than the test gas
8 - 4.4 Stability (continuous duty apparatus)
8 - 4.5 Stability (spot-reading apparatus)
8 - 4.6 Alarm
8 - 4.7 Temperature
9 - 4.8 Pressure
9 - 4.9 Humidity
9 - 4.10 Air velocity
9 - 4.11 Flow rate
9 - 4.12 Orientation
9 - 4.13 Vibration
9 - 4.14 Drop test (applicable to portable apparatus and remote sensors)
9 - 4.15 Warm-up time (not applicable to spot-reading apparatus)
9 - 4.15.1 Fixed and transportable apparatus
10 - 4.15.2 Continuous duty portable apparatus
10 - 4.16 Time of response (not applicable to spot-reading apparatus)
10 - 4.17 Minimum time to operate (spot-reading apparatus)
10 - 4.18 High gas concentration above the measuring range
10 - 4.18.1 Non-ambiguity test
10 - 4.18.2 Residual effect test
10 - 4.19 Battery capacity
10 - 4.19.1 Battery-powered portable continuous duty apparatus
10 - 4.19.2 Battery-powered portable spot-reading apparatus
11 - 4.20 Power supply variations
11 - 4.20.1 General
11 - 4.20.2 AC and external d.c. powered apparatus
11 - 4.20.3 Other power supply ranges
11 - 4.21 Power supply interruptions, voltage transients and step changes of voltage
11 - 4.22 Addition of sampling probe
11 - 4.23 Dust
11 - 4.24 Poisons and other gases
11 - 4.24.1 Poisons
11 - 4.24.2 Other gases
11 - 4.25 Electromagnetic compatibility
11 - 5 Field calibration kit

Specifies requirements for group II (as defined in part 1) portable,transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines sesceptible to firedamp (i.e. group I). This Standard is restricted to apparatus intended for the detection and measurements of combustible gas or vapour concentrations with air up to 100 percent lower explosive limit (LEL).

This part of AS/NZS 61779 specifies requirements for group II (as defined in part 1) portable, transportable and fixed apparatus for the detection and measurement of combustible gas or vapour concentrations with air. The apparatus, or parts thereof, may be installed or used in potentially explosive atmospheres, other than mines susceptible to firedamp (i.e. group I). The requirements and test methods applicable to the apparatus covered by this standard are specified in part 1.This standard is restricted to apparatus intended for the detection and measurement of combustible gas or vapour concentrations with air up to 100% lower explosive limit (LEL).

Committee
EL-014
DocumentType
Standard
ISBN
0 7337 3256 9
Pages
5
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 61779-4:1998 Identical

First published as part of AS 1827-1975.Revised and redesignated as AS 2275.1-1979.AS 2275.2 first published 1979.AS 2275.1-1979 and AS 2275.2-1979 jointly revised, amalgamated and redesignated in part as AS/NZS 61779.4:2000. First published as part of AS 1827-1975. Revised and redesignated as AS 2275.1-1979. AS 2275.2 first published 1979. AS 2275.1-1979 and AS 2275.2-1979 jointly revised, amalgamated and redesignated in part as AS/NZS 61779.4:2000.

AS 4976-2008 The removal and disposal of underground petroleum storage tanks
HB 13-2007 Electrical equipment for hazardous areas
HB 13-2000 Electrical equipment for hazardous areas

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.