MEASUREMENT OF LIQUID FLOW IN CLOSED CONDUITS BY WEIGHING METHOD
Available format(s)

Hardcopy , PDF

Superseded date

08-27-2021

Language(s)

English

Published date

01-01-2011

Preview

Foreword
Standards Committee Roster
1 General
  1.1 Scope and Field of Application
  1.2 References
  1.3 Definitions
  1.4 Symbols
2 Principles
  2.1 Statement of the Principles
  2.2 Accuracy of the Method
3 Apparatus
  3.1 Diverter
  3.2 Time-Measuring Apparatus
  3.3 Weighing Tank
  3.4 Weighing Device
  3.5 Auxiliary Measurements
4 Procedure
  4.1 Static Weighing Method
  4.2 Dynamic Weighing Method
  4.3 Common Provisions
5 Calculation of Flow Rate
  5.1 Calculation of Mass Flow Rate
  5.2 Calculation of Volume Flow Rate
6 Uncertainties in the Measurement of Flow Rate
Appendices
A - Corrections on the Measurement of Filling Time
B - Density of Pure Water

Specifies a method of liquid flow rate measurement in closed conduits by measuring the mass of liquid delivered into a weighing tank in a known time interval.

DocumentType
Standard
Pages
27
ProductNote
Reconfirmed 2006
PublisherName
American Society of Mechanical Engineers
Status
Superseded
SupersededBy
Supersedes

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.