Standard Specification for Aluminum 1350 Drawing Stock for Electrical Purposes
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

10-15-2012

CONTAINED IN VOL. 02.03, 2017 Covers aluminum 1350 drawing stock 0.375 in. (9.52 mm) to 1.000 in. (25.40 mm) in diameter for drawing into wire for electrical conductors.

1.1This specification covers aluminum 1350 drawing stock 0.375 in. (9.52 mm) to 1.000 in. (25.40 mm) in diameter, in the tempers shown in Table 1, for drawing into wire for electrical conductors (Explanatory Note 1 and Note 2).

TABLE 1 Tensile Property LimitsA

Temper

Tensile Strength

ksi

MPa

1350-O

8.5–14.0

59–97

1350-H12 and -H22

12.0–17.0

83–117

1350-H14 and -H24

15.0–20.0A

103–138

1350-H16 and -H26

17.0–22.0A

117–152

A Applicable to stock sizes through 0.500-in. (12.70-mm) diameter. The values to apply for larger sizes in these tempers shall be negotiated at time of inquiry.

1.2The SI values of density and resistivity are to be regarded as the standard. For all other properties the inch-pound values are to be regarded as standard and the SI units may be approximate.

Note 1Prior to 1975, aluminum 1350 was designated as EC aluminum.

Note 2The aluminum and temper designations conform to ANSI H35.1. Aluminum 1350 corresponds to unified numbering system A91350 in accordance with Practice E527.
TABLE 2 Chemical RequirementsA

Element

Composition, %

Silicon, max

0.10

Iron, max

0.40

Copper, max

0.05

Manganese, max

0.01

Chromium, max

0.01

Zinc, max

0.05

Boron, max

0.05

Gallium, max

0.03

Vanadium plus titanium, total, max

0.02

Other elements, each, max

0.03

Other elements, total, max

0.10

Aluminum, min

99.50

A Analysis shall regularly be made only for the elements specified in this table. If, however, the presence of other elements is suspected or indicated in amounts greater than the specified limits, further analysis shall be made to determine that these elements are not present in amounts in excess of the specified limits.
TABLE 3 Electrical Resistivity Limits

Temper

Resistivity, Ω·
mm 2/m, max

Equivalent Volume
Conductivity,
% IACS, min

1350-O

0.027899

61.8

1350-H12 and -H22

0.028035

61.5

1350-H14 and -H24

0.028080

61.4

1350-H16 and -H26

0.028126

61.3


TABLE 4 Equivalent Resistivity Values at 20°CA

Material

Volume Conductivity,
% IACS

Resistivity Constants

Volume

Ω·mm 2/m

Ω·cmil/ft

μΩ·in.

μΩ·cm

Copper

100

0.017241

10.371

0.67879

1.7241

Aluminum

61.3

0.028126

16.919

1.1073

2.8126

61.4

0.028080

16.891

1.1055

2.8080

61.5

0.028035

16.864

1.1037

2.8035

61.8

0.027899

16.782

1.0984

2.7899

A The equivalent resistivity values for 100 % IACS conductivity were each computed from the fundamental IEC value (1/58 Ω·mm2/m) using conversion factors each accurate to at least seven significant figures. Corresponding values for other conductivities (aluminum) were derived from these by multiplying by the reciprocal of the conductivity ratios accurate to at least seven significant figures.
TABLE 5 Diameter Tolerances

Specified Diameter, in.
(mm)

Tolerance, in. (mm), Plus or Minus

Deviation of MeanA
Diameter from
Specified Diameter

Deviation at Any
Point from
Specified Diameter

0.375–0.500 (9.52–12.70)
0.501–1.00 (12.73–25.40)

0.020 (0.51)
0.025 (0.64)

0.030 (0.76)
0.035 (0.89)

A For this specification, mean diameter is the average of the maximum diameter and the minimum diameter measured in the same transverse plane along the length.

Committee
B 01
DocumentType
Standard
Pages
4
ProductNote
Reconfirmed 2012
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
UNE 38116:2016 Identical

ASTM B 557 : 2015 : REDLINE Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy Products
ASTM E 527 : 2016 : REDLINE Standard Practice for Numbering Metals and Alloys in the Unified Numbering System (UNS)
ASTM E 227 : 1990 : R1996 Standard Test Method for Optical Emission Spectrometric Analysis of Aluminum and Aluminum Alloys by the Point-to-Plane Technique (Withdrawn 2002)
ANSI H35.1 : 2006 ALLOY AND TEMPER DESIGNATION SYSTEMS FOR ALUMINUM
ASTM B 193 : 2016 : REDLINE Standard Test Method for Resistivity of Electrical Conductor Materials

View more information
US$66.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.