Standard Practice for Installing Factory-Made Corrugated Aluminum Culverts and Storm Sewer Pipe
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

11-01-2009

CONTAINED IN VOL. 02.02, 2015 Specifies procedures, soils, and soil placement for the proper installation of corrugated aluminum culverts and storm sewers in either trench or projection installations.

1.1 This practice describes procedures, soils, and soil placement for the proper installation of corrugated aluminum culverts and storm sewers in either trench or projection installations. A typical trench installation is shown in Fig. 1, and a typical embankment (projection) installation is shown in Fig. 2. The pipes described in this practice are manufactured in a factory and furnished to the job in lengths ordinarily from 10 to 30 ft [3 to 9 m], with 20 ft [6 m] being common, for field joining. This practice applies to structures designed in accordance with Practice B790/B790M.

1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.2.1 SI UnitsSI units are shown in the text in brackets, and they are the applicable values for metric installation.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


FIG. 1 Typical Trench Installation


FIG. 2 Typical Embankment (Projection) Installation

Committee
B 07
DevelopmentNote
Supersedes ASTM B 788. (11/2004)
DocumentType
Standard Practice
Pages
5
ProductNote
Reconfirmed 2009
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM B 790/B790M : 2016 : REDLINE Standard Practice for Structural Design of Corrugated Aluminum Pipe, Pipe-Arches, and Arches for Culverts, Storm Sewers, and Other Buried Conduits
ASTM B 745/B745M : 2015 : REDLINE Standard Specification for Corrugated Aluminum Pipe for Sewers and Drains
ASTM D 2167 : 2015 : REDLINE Standard Test Method for Density and Unit Weight of Soil in Place by the Rubber Balloon Method
ASTM D 6938 : 2017-03 TEST METHOD FOR IN-PLACE DENSITY AND WATER CONTENT OF SOIL AND SOIL-AGGREGATE BY NUCLEAR METHODS (SHALLOW DEPTH)
ASTM D 698 : 2013-05 TEST METHODS FOR LABORATORY COMPACTION CHARACTERISTICS OF SOIL USING STANDARD EFFORT (12400 FT-LBF/FT[3] (600 KN-M/M[3]))

View more information
US$75.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.