Standard Test Method for Non-Destructive Assay of Nuclear Material in Waste by Passive and Active Neutron Counting Using a Differential Die-Away System

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-15-2019

This test method covers a system that performs nondestructive assay (NDA) of uranium or plutonium, or both, using the active, differential die-away technique (DDT), and passive neutron coincidence counting.

1.1This test method covers a system that performs nondestructive assay (NDA) of uranium or plutonium, or both, using the active, differential die-away technique (DDT), and passive neutron coincidence counting. Results from the active and passive measurements are combined to determine the total amount of fissile and spontaneously-fissioning material in drums of scrap or waste. Corrections are made to the measurements for the effects of neutron moderation and absorption, assuming that the effects are averaged over the volume of the drum and that no significant lumps of nuclear material are present. These systems are most widely used to assay low-level and transuranic waste, but may also be used for the measurement of scrap materials. The examples given within this test method are specific to the second-generation Los Alamos National Laboratory (LANL) passive-active neutron assay system.

1.1.1In the active mode, the system measures fissile isotopes such as 235U and 239Pu. The neutrons from a pulsed, 14-MeV neutron generator are thermalized to induce fission in the assay item. Between generator pulses, the system detects prompt-fission neutrons emitted from the fissile material. The number of detected neutrons between pulses is proportional to the mass of fissile material. This method is called the differential die-away technique.

1.1.2In the passive mode, the system detects time-coincident neutrons emitted from spontaneously fissioning isotopes. The primary isotopes measured are 238Pu, 240 Pu, and 242Pu; however, the system may be adapted for use on other spontaneously-fissioning isotopes as well, such as kilogram quantities of 238U. The number of coincident neutrons detected is proportional to the mass of spontaneously-fissioning material.

1.2The active mode is used to assay fissile material in the following ranges.

1.2.1For uranium-only bearing items, the DDT can measure the 235U content in the range from about 0.02 to over 100 g. Small mass uranium-bearing items are typically measured using the active mode and only large mass items are measured in passive mode.

1.2.2For plutonium-only bearing items, the DDT method measures the 239Pu content in the range between about 0.01 and 20 g.

1.3The passive mode is capable of assaying spontaneously-fissioning nuclei, over a nominal range from 0.05 to 15 g 240Pu equivalent.

1.4This test method requires knowledge of the relative abundances of the plutonium or uranium isotopes to determine the total plutonium or uranium mass.

1.5This test method will give biased results when the waste form does not meet the calibration specifications and the measurement assumptions presented in this test method regarding the requirements for a homogeneous matrix, uniform source distribution, and the absence of nuclear material lumps, to the extent that they effect the measurement.

1.6The complete active and passive assay of a 208 L drum is nominally 10 min or less but either mode can be extended to meet data quality objectives.

1.7Some improvements to this test method have been reported (1, 2, 3, 4).2 Discussions of these improvements are not included in this test method although improvements continue to occur.

1.8The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.9This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8.

1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Committee
C 26
DocumentType
Test Method
Pages
14
ProductNote
THIS STANDARD ALSO REFERS TO : DOE Order 435.1,DOE Order 474.1,DOE Order 474.1,DOE /WIPP-069,10 CFR Part 71,40 CFR Part 191,USNRC Regulatory Guide 5.11,USNRC Regulatory Guide 5.53
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

ASTM C 1490 : 2014 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel

ASTM C 1207 : 1997 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1207 : 2003 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1207 : 2010 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1207 : 2010 : R2018 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1490 : 2001 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1215 : 1992 : R2012 : EDT 1 Standard Guide for Preparing and Interpreting Precision and Bias Statements in Test Method Standards Used in the Nuclear Industry
ASTM C 1215 : 1992 : R1997 Standard Guide for Preparing and Interpreting Precision and Bias Statements in Test Method Standards Used in the Nuclear Industry
ASTM C 1030 : 2003 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1490 : 2004 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1030 : 2010 : R2018 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1030 : 2010 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1673 : 2007 : EDT 1 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1673 : 2010 : REV A : R2018 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1215 : 2018 Standard Guide for Preparing and Interpreting Precision and Bias Statements in Test Method Standards Used in the Nuclear Industry
ASTM C 1592 : 2004 Standard Guide for Nondestructive Assay Measurements
ASTM C 1673 : 2010 : REV A Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1673 : 2007 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1215 : 1992 : R2006 Standard Guide for Preparing and Interpreting Precision and Bias Statements in Test Method Standards Used in the Nuclear Industry
ASTM C 1673 : 2010 : REV A : EDT 1 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1490 : 2014 : R2023 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1030 : 1995 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1490 : 2014 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1490 : 2004 : R2010 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1673 : 2010 Standard Terminology of C26.10 Nondestructive Assay Methods

View more information
US$69.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.