Standard Test Method for Nondestructive Assay of Plutonium by Passive Neutron Multiplicity Counting

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-20-2017

CONTAINED IN VOL. 12.01, 2017 Specifies the nondestructive assay of plutonium in forms such as metal, oxide, scrap, residue, or waste using passive neutron multiplicity counting.

1.1This test method describes the nondestructive assay of plutonium in forms such as metal, oxide, scrap, residue, or waste using passive neutron multiplicity counting. This test method provides results that are usually more accurate than conventional neutron coincidence counting. The method can be applied to a large variety of plutonium items in various containers including cans, 208-L drums, or 1900-L Standard Waste Boxes. It has been used to assay items whose plutonium content ranges from 1 g to 1000s of g.

1.2There are several electronics or mathematical approaches available for multiplicity analysis, including the multiplicity shift register, the Euratom Time Correlation Analyzer, and the List Mode Module, as described briefly in Ref. (1).2

1.3This test method is primarily intended to address the assay of 240Pu-effective by moments-based multiplicity analysis using shift register electronics (1, 2, 3) and high efficiency neutron counters specifically designed for multiplicity analysis.

1.4This test method requires knowledge of the relative abundances of the plutonium isotopes to determine the total plutonium mass (See Test Method C1030).

1.5This test method may also be applied to modified neutron coincidence counters (4) which were not specifically designed as multiplicity counters (that is, HLNCC, AWCC, etc), with a corresponding degradation of results.

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
C 26
DocumentType
Test Method
Pages
14
ProductNote
Reconfirmed 2017
PublisherName
American Society for Testing and Materials
Status
Current
Supersedes

ASTM C 1592/C1592M : 2021 Standard Guide for Making Quality Nondestructive Assay Measurements
ASTM C 1490 : 2014 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM F 1701 : 2012 : R2018 Standard Specification for Unused Rope with Special Electrical Properties

ASTM C 1207 : 1997 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1458 : 2009 Standard Test Method for Nondestructive Assay of Plutonium, Tritium and <sup>241</sup>Am by Calorimetric Assay
ASTM C 1207 : 2003 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1458 : 2016 Standard Test Method for Nondestructive Assay of Plutonium, Tritium and <sup >241</sup>Am by Calorimetric Assay
ASTM C 1458 : 2000 Standard Test Method for Nondestructive Assay of Plutonium, Tritium and <sup>241</sup>Am by Calorimetric Assay
ASTM C 1458 : 2016 : REDLINE Standard Test Method for Nondestructive Assay of Plutonium, Tritium and <sup >241</sup>Am by Calorimetric Assay
ASTM C 1207 : 2010 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1207 : 2010 : R2018 Standard Test Method for Nondestructive Assay of Plutonium in Scrap and Waste by Passive Neutron Coincidence Counting
ASTM C 1490 : 2001 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1030 : 2003 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1458 : 2009 : EDT 1 Standard Test Method for Nondestructive Assay of Plutonium, Tritium and <sup>241</sup>Am by Calorimetric Assay
ASTM C 1490 : 2004 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1030 : 2010 : R2018 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1030 : 2010 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1673 : 2007 : EDT 1 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1673 : 2010 : REV A : R2018 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1490 : 2014 : REDLINE Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1592 : 2004 Standard Guide for Nondestructive Assay Measurements
ASTM C 1673 : 2010 : REV A Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1673 : 2007 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1673 : 2010 : REV A : EDT 1 Standard Terminology of C26.10 Nondestructive Assay Methods
ASTM C 1490 : 2014 : R2023 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1030 : 1995 Standard Test Method for Determination of Plutonium Isotopic Composition by Gamma-Ray Spectrometry
ASTM C 1490 : 2014 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1490 : 2004 : R2010 Standard Guide for the Selection, Training and Qualification of Nondestructive Assay (NDA) Personnel
ASTM C 1673 : 2010 Standard Terminology of C26.10 Nondestructive Assay Methods

View more information
US$69.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.