1.1This test method covers the simultaneous collection and separate measurements of gaseous fluoride (for example, hydrogen fluoride) and particulate fluoride found in certain industrial workplaces. The gaseous fluorides and particulate fluorides collected are reported in terms of fluoride. The method covers sample collection, preparation, and fluoride measurement.
1.2The procedure is not applicable to the collection or analysis of gaseous fluoro compounds (for example, fluorocarbon or fluorosulfur compounds).
1.3The values stated in SI units are to be regarded as the standard.
1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.