Standard Test Method for Determination of Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler Methodology)
Superseded date

11-11-2014

Published date

03-10-1997

1.1 This test method covers a procedure for the determination of formaldehyde (HCHO) and other aldehydes in air. This test method is specific for formaldehyde but, with modification, fourteen other aldehydes can be detected.

1.2 This test method involves drawing air through a cartridge containing silica gel coated with 2,4-dinitrophenylhydrazine (DNPH) reagent. Aldehydes and ketones readily form a stable derivative with the DNPH reagent. The DNPH derivative is analyzed for aldehydes and ketones utilizing high performance liquid chromatography (HPLC). The sampling procedure is a modification of U.S. EPA Method TO-11 (see 2.2).

1.3 This test method is based on the specific reaction of carbonyl compounds (aldehydes and ketones) with DNPH in the presence of an acid to form stable derivatives according to the reaction shown in Fig. 1, (where: both and are alkyl or aromatic groups (ketones), or both, or either or is a hydrogen atom (aldehydes)). The determination of formaldehyde, as a DNPH derivative, is similar to that of U.S. EPA Method TO-11 in that it utilizes HPLC. The detection limits have been extended to other aldehydes and ketones that can be determined as outlined in Section 13. This test method is suitable for determination of formaldehyde in the concentration range of high ppb to low ppm (v/v).

1.4 The sampling method gives a time-weighted average (TWA) sample. It can be used for long-term (1 to 24 h) or short-term (5 to 60 min) sampling of indoor air for formaldehyde.

1.5 The sampling flow rate, as described in this test method is presently limited to about 1.5 L/min. This limitation is principally due to the high pressure drop (>8 kPa at 1.0 L/min) across the DNPH-coated silica gel cartridges. This procedure is not compatible with pumps used in personal sampling equipment, that are inadequate for this application.

1.6 This test method instructs the user to purchase Sep-PAK chromatographic grade silica gel cartridges and apply acidified DNPH in situ to each cartridge, if the user desires to prepare his own cartridges. The silica gel in the Sep-PAK cartridge have a particle size of 55 to 105 [mu]m. Pre-coated DNPH silica gel cartridges are also available, if the user desires to purchase them.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 22
DocumentType
Test Method
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 6399 : 2018 Standard Guide for Selecting Instruments and Methods for Measuring Air Quality in Aircraft Cabins
ASTM D 7297 : 2014 Standard Practice for Evaluating Residential Indoor Air Quality Concerns
ASTM D 7339 : 2018 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption / Gas Chromatography
ASTM D 8142 : 2017 Standard Test Method for Determining Chemical Emissions from Spray Polyurethane Foam (SPF) Insulation using Micro-Scale Environmental Test Chambers
ASTM D 7911 : 2014 Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test
ASTM D 7706 : 2017 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
ASTM E 1333 : 2014 Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber
ASTM D 6007 : 2014 Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber
ASTM D 7143 : 2017 Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products
ASTM D 6803 : 2013 Standard Practice for Testing and Sampling of Volatile Organic Compounds (Including Carbonyl Compounds) Emitted from Paint Using Small Environmental Chambers
ASTM D 6670 : 2018 Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products
ASTM D 6177 : 2014 Standard Practice for Determining Emission Profiles of Volatile Organic Chemicals Emitted from Bedding Sets

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.