Standard Test Method for Measurement of Hexane Extractable Content of Polyolefins
Available format(s)

PDF

Superseded date

07-30-2021

Language(s)

English

Published date

06-01-2013

CONTAINED IN VOL. 08.03, 2015 Defines an extraction/gravimetric procedure for determination of the amount of hexane soluble low molecular weight material present in polyethylene, polypropylene, ethylene-propylene copolymers, and ethylenevinyl acetate copolymers.

1.1This test method describes an extraction/gravimetric procedure for determination of the amount of hexane soluble low molecular weight material present in polyethylene, polypropylene, ethylene-propylene copolymers, and ethylene-vinyl acetate copolymers. This test method is a modification of the Food and Drug Administration (FDA) procedure for determining hexane extractables of polyolefins. This test method is based upon the presumption that the weight of the residue extract present in the solvent is equal to the amount extracted from the film sample and could therefore be quantified by measuring the weight loss of the extracted film, eliminating the complex and time-consuming evaporation process described in 21 CFR 177.1520.

1.2This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.3The values stated in SI units are to be regarded as the standard. Units used in 21 CFR 177.1520 are also used in this test method. Units are in conformance with Federal Code 21 CFR 177.1520, from which this test method is derived.

Note 1There is no known ISO equivalent to this standard.

Committee
D 20
DevelopmentNote
Supersedes ASTM D 647. (02/2002)
DocumentType
Redline
Pages
5
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 5577 : 1994 Standard Guide for Techniques to Separate and Identify Contaminants in Recycled Plastics
ASTM D 5577 : 1994 : R2003 Standard Guide for Techniques to Separate and Identify Contaminants in Recycled Plastics
BS ISO 12891-2:2014 Retrieval and analysis of surgical implants Analysis of retrieved surgical implants
ASTM F 561 : 2013 Standard Practice for Retrieval and Analysis of Medical Devices, and Associated Tissues and Fluids
13/30242622 DC : 0 BS ISO 12891-2 - RETRIEVAL AND ANALYSIS OF SURGICAL IMPLANTS - PART 2: ANALYSIS OF RETRIEVED SURGICAL IMPLANTS
ISO 12891-2:2014 Retrieval and analysis of surgical implants Part 2: Analysis of retrieved surgical implants
ASTM D 5577 : 1994 : R2010 : EDT 1 Standard Guide for Techniques to Separate and Identify Contaminants in Recycled Plastics (Withdrawn 2019)

CFR 21(PTS170-199) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 170-199
ASTM D 1239 : 2014 : REDLINE Standard Test Method for Resistance of Plastic Films to Extraction by Chemicals

View more information
US$66.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.