Standard Test Method for pH Measurement of Water of Low Conductivity

Available format(s)

PDF

Language(s)

English

Published date

06-01-2016

CONTAINED IN VOL. 11.01, 2017 Pertains to determine the pH of water samples with a conductivity of 2 to 100 [mu]S/cm over the pH range of 3 to 11 and is frequently used in power generation low conductivity samples.

1.1This test method is applicable to determine the pH of water samples with a conductivity of 2 to 100 μS/cm over the pH range of 3 to 11 and is frequently used in power generation low conductivity samples. pH measurements of water of low conductivity are problematic. Specifically, this test method avoids contamination of the sample with atmospheric gases and prevents volatile components of the sample from escaping. This test method provides for pH electrodes and apparatus that address additional considerations discussed in Annex A2. This test method also minimizes problems associated with the sample's pH temperature coefficient when the operator uses this test method to calibrate an on-line pH monitor or controller (see Appendix X1).

1.2This test method covers the measurement of pH in water of low conductivity with a lower limit of 2.0 μS/cm, utilizing a static grab-sample procedure where it is not practicable to take a real-time flowing sample.

Note 1:Test Method D5128 for on-line measurement is preferred over this method whenever possible. Test Method D5128 is not subject to the limited conductivity range, temperature interferences, potential KCl contamination, and time limitations found with this method.

1.3For on-line measurements in water with conductivity of 100 μS/cm and higher, see Test Method D6569.

1.4For laboratory measurements in water with conductivity of 100 μS/cm and higher, see Test Method D1293.

1.5The values stated in SI units are to be regarded as standard.

1.6This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 19
DocumentType
Redline
Pages
12
PublisherName
American Society for Testing and Materials
Status
Current

ASTM E 2635 : 2014 : REDLINE Standard Practice for Water Conservation in Buildings Through In-Situ Water Reclamation
ASTM D 6764 : 2002 : R2013 Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels
ASTM D 6764 : 2002 : R2007 Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels
ASTM D 1293 : 2018 : REDLINE Standard Test Methods for pH of Water
ASTM D 6764 : 2002 Standard Guide for Collection of Water Temperature, Dissolved-Oxygen Concentrations, Specific Electrical Conductance, and pH Data from Open Channels
ASTM D 5128 : 2014 : REDLINE Standard Test Method for On-Line pH Measurement of Water of Low Conductivity

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM D 4453 : 2017 : REDLINE Standard Practice for Handling of High Purity Water Samples
ASTM D 5128 : 2014 : REDLINE Standard Test Method for On-Line pH Measurement of Water of Low Conductivity
ASTM D 6569 : 2014 : REDLINE Standard Test Method for On-Line Measurement of pH (Withdrawn 2023)

View more information
US$75.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.