• There are no items in your cart

ASTM D 7953 : 2014

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Arc Testing Method
Available format(s)

Hardcopy , PDF

Superseded date

01-28-2020

Language(s)

English

Published date

07-01-2014

CONTAINED IN VOL. 04.13, 2017 Defines method for geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, canals, and other containment facilities.

1.1This practice is a performance-based standard for an electrical method for locating leaks in exposed geomembranes. For clarity, this practice uses the term “leak” to mean holes, punctures, tears, knife cuts, seam defects, cracks, and similar breaches in an installed geomembrane (as defined in 3.2.4).

1.2This practice can be used for geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, canals, and other containment facilities. It is applicable for geomembranes made of materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous geomembrane, and any other electrically insulating materials. This practice is best applicable for locating geomembrane leaks where the proper preparations have been made during the construction of the facility.

1.3The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
D 35
DocumentType
Standard Practice
Pages
4
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 7703 : 2016 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance Method
ASTM D 7002 : 2016 : REDLINE Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
ASTM D 6747 : 2015 Standard Guide for Selection of Techniques for Electrical Leak Location of Leaks in Geomembranes
ASTM D 7703 : 2016 : REDLINE Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance Method
ASTM D 7002 : 2016 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
ASTM D 6747 : 2015 : REDLINE Standard Guide for Selection of Techniques for Electrical Leak Location of Leaks in Geomembranes

ASTM D 7002 : 2003 Standard Practice for Leak Location on Exposed Geomembranes Using the Water Puddle System
ASTM D 4439 : 2020 Standard Terminology for Geosynthetics
ASTM D 4439 : 2015 Standard Terminology for Geosynthetics
ASTM D 7002 : 2010 Standard Practice for Leak Location on Exposed Geomembranes Using the Water Puddle System
ASTM D 7703 : 2016 : REDLINE Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance Method
ASTM D 6747 : 2015 : REDLINE Standard Guide for Selection of Techniques for Electrical Leak Location of Leaks in Geomembranes
ASTM D 7002 : 2016 : REDLINE Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
ASTM D 4439 : 2011 Standard Terminology for Geosynthetics
ASTM D 6747 : 2002 : EDT 1 Standard Guide for Selection of Techniques for Electrical Detection of Potential Leak Paths in Geomembrane
ASTM D 6747 : 2004 Standard Guide for Selection of Techniques for Electrical Detection of Potential Leak Paths in Geomembrane
ASTM D 4439 : 2015 : REV A Standard Terminology for Geosynthetics
ASTM D 7703 : 2011 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance System
ASTM D 7002 : 2016 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method
ASTM D 4439 : 2002 Standard Terminology for Geosynthetics
ASTM D 6747 : 2012 Standard Guide for Selection of Techniques for Electrical Detection of Leaks in Geomembranes
ASTM D 4439 : 2017 Standard Terminology for Geosynthetics
ASTM D 7703 : 2016 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance Method
ASTM D 4439 : 2001 Standard Terminology for Geosynthetics
ASTM D 4439 : 2014 Standard Terminology for Geosynthetics
ASTM D 4439 : 2004 Standard Terminology for Geosynthetics
ASTM D 6747 : 2015 Standard Guide for Selection of Techniques for Electrical Leak Location of Leaks in Geomembranes
ASTM D 7703 : 2015 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance Method
ASTM D 4439 : 2017-08 TERMINOLOGY FOR GEOSYNTHETICS
ASTM D 4439 : 2000 Standard Terminology for Geosynthetics
ASTM D 4439 : 2018 Standard Terminology for Geosynthetics
ASTM D 7002 : 2015 Standard Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Puddle Method

View more information
US$66.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.