Standard Test Methods for Nonrigid Vinyl Chloride Polymer Tubing Used for Electrical Insulation
Available format(s)

Hardcopy , PDF

Superseded date

02-15-2021

Language(s)

English

Published date

12-10-2013

These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C)2 nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation.

1.1These test methods cover the testing of general-purpose (Grade A), low-temperature (Grade B), and high-temperature (Grade C)2 nonrigid vinyl chloride polymer tubing, or its copolymers with other materials, for use as electrical insulation. For the purpose of these test methods nonrigid tubing shall be tubing having an initial elongation in excess of 100 % at break.

Note 1These test methods are similar but not identical to those in IEC 60684–2.

1.2The values stated in inch-pound units are to be regarded as standard, except for temperature, which shall be expressed in degrees Celsius. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3The procedures appear in the following sections:


Procedure


Section

ASTM Reference Standard

Brittleness Temperature

43 – 45

D746

Corrosion Tests

74 – 85

D1000

Dielectric Breakdown Voltage at High Humidity

65 – 73

E104

Dielectric Breakdown Voltage

58 – 64

D149

Dimensional Tests

8 – 14

D374

Effect of Elevated Temperatures

25 – 36

D412

Flammability Test

15 – 21

Oil Resistance Test

35 – 42

D471

Penetration Test

46 – 51

Sampling

6

Strain Relief Test

68 – 73

Tension Test

22 – 24

D412

Test Conditions

7

Volume Resistivity

52 – 57

D257


1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 5.

1.5For fire test caveats, see Section 15.

Committee
D 09
DocumentType
Test Method
Pages
13
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 8355 : 2020 Standard Test Methods for Flammability of Electrical Insulating Materials Used for Sleeving or Tubing
ASTM D 5025 : 2020 : REV A Standard Specification for Laboratory Burner Used for Small-Scale Burning Tests on Plastic Materials
ASTM D 3006 : 2010 : R2017 Standard Specification for Polyethylene Plastic Pressure-Sensitive Electrical Insulating Tape (Withdrawn 2022)
ASTM D 1675 : 2018 Standard Test Methods for Polytetrafluoroethylene Tubing
ASTM D 922 : 2018 Standard Specification for Nonrigid Vinyl Chloride Polymer Tubing
ASTM D 2671 : 2013 Standard Test Methods for Heat-Shrinkable Tubing for Electrical Use

ASTM D 1000 : 2017 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 1711 : 2002 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2011 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2011 : REV A Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2013 Standard Terminology Relating to Electrical Insulation
ASTM D 1000 : 2004 : EDT 1 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 1000 : 2010 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 1711 : 1999 Standard Terminology Relating to Electrical Insulation
ASTM D 5032 : 2011 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
ASTM D 1711 : 2014 : REV A Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2015 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2014 Standard Terminology Relating to Electrical Insulation
ASTM D 1000 : 2009 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 5032 : 2019 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions
ASTM D 1711 : 2020 Standard Terminology Relating to Electrical Insulation
ASTM D 1711 : 2008 Standard Terminology Relating to Electrical Insulation
ASTM D 1000 : 1999 Standard Test Method for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 1000 : 2004 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications
ASTM D 5032 : 1997 Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Glycerin Solutions

View more information
US$83.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.