• There are no items in your cart

BS 7729:1994

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Specification for instrument transformers. Three-phase voltage transformers for voltage levels having Um up to 52 kV

Available format(s)

Hardcopy , PDF

Superseded date

05-30-2008

Language(s)

English

Published date

04-15-1994

Committees responsible
National foreword
Foreword
CHAPTER I: General requirements applicable to all
three-phase voltage transformers
Section One - General
1. Scope
2. General
3. Service conditions
4. Definitions
Section Two - Rating and performance requirements
applicable to all three-phase voltage transformers
5. Standard values of rated voltage
6. Standard values of rated output
7. Standard values of rated voltage factor
8. Limits of temperature rise
9. Insulation requirements
9a. Short-circuit withstand capability
Section Three - Tests: General
10. Classification of tests
Section Four - Type tests
11. Temperature-rise tests
12. Short-circuit withstand capability test
13. Impulse tests on primary winding
14. Wet test for outdoor type transformers
Section Five - Routine tests
15. Verification of terminal markings
16. Power-frequency tests on primary windings
16a. Measurement of partial discharges
17. Power-frequency tests between sections and on
     secondary windings
Section Six - Special tests
18. Void
Section Seven - Marking
19. Rating plate markings
Section Eight - Terminal markings
20. General
21. Markings
CHAPTER II: General requirements for three-phase
measuring voltage transformers
Section Nine - General
22. Scope
23. Definitions
Section Ten - Accuracy requirements
24. Accuracy class designation
25. Limits of voltage error and phase displacement
Section Eleven - Tests for accuracy
26. Type tests
26a. Routine tests
Section Twelve - Marking
27. Marking of the rating plate of a measuring voltage
     transformer
CHAPTER III: Additional requirements for three-phase
protective voltage transformers
Section Thirteen - General
28. Scope
29. Definitions
Section Fourteen - Accuracy requirements
30. Accuracy class designation
31. Limits of voltage and phase displacement
Section Fifteen - Requirements for secondary windings
intended to produce a residual voltage
32. Rated secondary voltages
33. Rated output
34. Accuracy class
Section Sixteen - Tests for accuracy
35. Type tests
36. Routine tests
Section Seventeen - Marking
37. Marking of the rating plate of a three-phase
     protective voltage transformer
Figures

Requirements and tests for transformers with frequencies from 15 Hz to 100 Hz, for use with electrical instruments or electrical protective devices.

Committee
PEL/38
DevelopmentNote
Reviewed and confirmed by BSI, October 2007. (09/2007)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
IEC 60186:1987 Similar to

IEC 60038:2009 IEC standard voltages
BS 5622-1:1979 Guide for insulation co-ordination Terms, definitions, principles and rules
BS 5622-2:1979 Guide for insulation co-ordination Application guide
BS 7625:1993 Specification for voltage transformers
BS 923:1972 Guide on high-voltage testing techniques.

View more information
US$237.18
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.