• There are no items in your cart

BS 7970:2012

Current

Current

The latest, up-to-date edition.

Electric cables. Metal foil and longitudinally welded aluminium sheath constructions of power cables having XLPE insulation for rated voltages from 66 kV (Um = 72.5 kV) to 132 kV (Um = 145 kV)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

12-31-2012

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Construction of metal wire and foil sheaths
5 Marking of cables
6 Routine tests on cables
7 Sample tests on cables
8 Type tests on cables and components
Annexes
Annex A (normative) - Die penetrant test for weld
        integrity
Annex B (normative) - Test for peel strength of
        overlapped metal foil
Annex C (normative) - Test for adhesion strength
        of metal foil
Annex D (normative) - Test for impact
Annex E (normative) - Test for sidewall loading
Annex F (normative) - Test for corrosion
Bibliography

Describes requirements for construction and performance, and gives methods of test, for metal wire and foil sheath, or metal wire and longitudinally welded aluminium, or longitudinally welded aluminium constructions of power cables having XLPE insulation for rated voltages from 66 kV (U[m] = 72.5 kV) to 132 kV (U[m] = 145 kV).

This British Standard specifies requirements for construction and performance, and gives methods of test, for metal wire and foil sheath, or metal wire and longitudinally welded aluminium, or longitudinally welded aluminium constructions of power cables having XLPE insulation for rated voltages from 66 kV (Um = 72.5 kV) to 132 kV (Um = 145 kV). The tests and requirements in this British Standard are additional to the tests and requirements for cables and their accessories specified in BS 7912.

NOTE 1 In exceptional cases, with very low fault currents, foil sheath designs without metal wires may also be used.

NOTE 2 Tests described in BS 7912:2012, 15.2, 15.3 and 15.4 are not required in this standard.

This British Standard is applicable to single-core cables for usual conditions of installation and operation, but not to special cables, such as those designed for submarine applications.

NOTE 3 Annex A gives requirements for a die penetrant test for weld integrity. Annex B lists a test for peel strength of overlapped metal foil. Annex C lists test requirements for adhesion strength of metal foil. Annex D covers the test for impact and Annex E the test for sidewall loading. Annex F covers the test for corrosion.

Committee
GEL/20/16
DevelopmentNote
Supersedes BS 7970(2005) & 12/30244364 DC. (12/2012)
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Current
Supersedes

HD 632 : 1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
BS 7870-2:2011 LV and MV polymeric insulated cables for use by distribution and generation utilities Methods of test
BS EN 60228:2005 Conductors of insulated cables
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables

View more information
US$175.67
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.