• There are no items in your cart

BS EN 12820:2002

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Inspection and requalification of LPG tanks greater than 13 m3 underground

Available format(s)

Hardcopy , PDF

Superseded date

01-31-2010

Language(s)

English

Published date

05-28-2002

Foreword
Introduction
1 Scope
2 Terms and definitions
3 Safety
  3.1 Safety precautions
  3.2 Unsafe conditions
  3.3 Leaks
4 Written scheme
5 Tank inspection and requalification
  5.1 Routine inspection
  5.2 Periodic inspection
  5.3 Requalification
6 Inspection of tank and tank fittings
  6.1 Tank
  6.2 Tank fittings and immediate pipework
  6.3 Valve cover
  6.4 Bonding
  6.5 Pressure relief valves
  6.6 Pressure gauge
  6.7 Contents gauges
  6.8 Shut-off valves
  6.9 Studs, bolts, nuts, and washers
  6.10 Emergency valves
  6.11 Gaskets
  6.12 Pressure switch
  6.13 Temperature gauge
  6.14 Remotely operated valves
  6.15 Corrosion protection system
7 Site inspection
  7.1 Storage site
  7.2 Warning notices
8 Competence
  8.1 Routine inspection
  8.2 Periodic inspection
  8.3 Requalification
9 Records
  9.1 Tank data
  9.2 Reports
Annex A (informative) Internal visual inspection
        A.1 General
        A.2 Inspection techniques
        A.3 Records
        A.4 Additional inspection
Annex B (informative) Hydraulic pressure test
Annex C (informative) Acoustic emission testing
        C.1 General
        C.2 Safety precautions
        C.3 Acceptance criteria
Annex D (informative) Ultrasonic thickness test
        D.1 General
        D.2 Apparatus setting
        D.3 Control measurement
        D.4 Shell thickness measurements
        D.5 End thickness
        D.6 Interpretation
        D.7 Rejection criteria
Annex E (informative) Monitoring cathodic protection with
        sacrificial anodes
        E.1 General
        E.2 Records
        E.3 Procedure
        E.4 Measurement of the galvanic current
        E.5 Measurement of the potential difference of the
            tank to earth
        E.6 Results
Annex F (informative) Monitoring cathodic protection by
        impressed current
        F.1 General
        F.2 Apparatus
        F.3 Conditions
        F.4 Isolation resistance of the coating
            F.4.1 Procedure
            F.4.2 Calculation
        F.5 Results
        F.6 Checking intervals
Annex G (informative) Example of a report
Annex ZA (informative) A-deviations

Gives requirements for routine inspection, periodic inspection and requalification of underground and mounded LPG storage tanks of sizes greater than 13 m[3], and associated fittings; marking tanks and/or keeping records, as appropriate, as a result of routine inspection, periodic inspection and requalification

Committee
PVE/19
DevelopmentNote
Supersedes 97/706937 DC (06/2002)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NF EN 12820 : 2002 Identical
I.S. EN 12820:2002 Identical
EN 12820 : 2002 Identical
NS EN 12820 : 2002 Identical
UNI EN 12820 : 2004 Identical
DIN EN 12820:2002-08 Identical
NBN EN 12820 : 2002 Identical
UNE-EN 12820:2003 Identical
NEN EN 12820 : 2002 Identical
SN EN 12820 : 2002 Identical

View more information
US$237.18
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.