• There are no items in your cart

BS EN 50083-8:2013

Current
Current

The latest, up-to-date edition.

Cable networks for television signals, sound signals and interactive services Electromagnetic compatibility for networks
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-31-2014

Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Methods of measurement
5 Performance requirements
Annex A (informative) - A-deviations
Annex B (informative) - Frequency ranges of typical
        safety of life services
Annex C (informative) - Interdependence between the
        maximum allowable field strength and the
        minimum signal level at system outlet
Annex D (informative) - Measurements in other
        distances than the standard distance of 3 m
Annex E (informative) - GPS based leakage
        detection system for cable networks
Bibliography

Pertains to the radiation characteristics and immunity to electromagnetic disturbance of cable networks for television signals, sound signals and interactive services and covers the frequency range 0,15 MHz to 3,5 GHz.

1.1 General Standards of the EN 50083 and EN 60728 series deal with cable networks including equipment and associated methods of measurement for headend reception, processing and distribution of television and sound signals and for processing, interfacing and transmitting all kinds of data signals for interactive services using all applicable transmission media. These signals are typically transmitted in networks by frequency-multiplexing techniques. This includes for instance ? regional and local broadband cable networks, ? extended satellite and terrestrial television distribution systems, ? individual satellite and terrestrial television receiving systems, and all kinds of equipment, systems and installations used in such cable networks, distribution and receiving systems. The extent of this standardization work is from the antennas and/or special signal source inputs to the headend or other interface points to the network up to the terminal input of the customer premises equipment. The standardization work will consider coexistence with users of the RF spectrum in wired and wireless transmission systems. The standardization of any user terminals (i.e. tuners, receivers, decoders, multimedia terminals etc.) as well as of any coaxial, balanced and optical cables and accessories thereof is excluded. 1.2 Specific scope of EN 50083 8 This European Standard applies to the radiation characteristics and immunity to electromagnetic disturbance of cable networks for television signals, sound signals and interactive services and covers the frequency range 0,15 MHz to 3,5 GHz. It should be noted that measurements below 30 MHz are not generally considered useful in the context of cable networks and are difficult to perform in practice. Application of the harmonized standard EN 50529-2 provides presumption of conformance to the EMC Directive. Therefore, to fulfil the requirements of EN 50529-2, it is necessary to use cable network equipment that satisfies the requirements of EN 50083-2 regarding limits of radiation and of immunity to external fields. This European Standard specifies methods of measurement and EMC performance requirements under operating conditions (in situ) to ensure the ongoing EMC integrity of cable networks. Cable networks beyond the system outlets (e.g. the receiver lead, in simplest terms) which begin at the system outlet and end at the input to the subscriber\'s terminal equipment are not covered by the standard EN 50083 8. Requirements for the electromagnetic compatibility of receiver leads are laid down in EN 60966 2 4, EN 60966 2 5 and EN 60966 2 6. Cable networks and a wide range of radio services have to coexist. These include for example the emergency services, safety of life, broadcasting, aeronautical, radio navigation services and also land mobile, amateur and cellular radio services. Frequency ranges of typical safety of life services are listed in Annex B. Additional protection for certain services may be required by national regulations.

Committee
EPL/100
DevelopmentNote
Supersedes 96/204501 DC. (08/2002)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC 60512-15-2:2018 Identical
EN 50083-8:2013 Identical
NEN EN 50083-8 : 2014 Identical
SN EN 50083-8 : 2013 Identical
UNE-EN 50083-8:2003 Identical
DIN EN 50083-8 : 2014 Identical
I.S. EN 50083-8:2013 Identical
NBN EN 50083-8 : 2014 Identical
NF EN 50083-8 : 2014 Identical

EN 60966-2-4:2016 Radio Frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
CISPR 13:2009+AMD1:2015 CSV Sound and television broadcast receivers and associated equipment -Radio disturbance characteristics - Limits and methods of measurement
EN 55013:2013/A1:2016 SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 13:2009, MODIFIED)
EN 55016-1-4:2010/A2:2017 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017)
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements
IEC 60966-2-6:2016 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
CISPR 16-1-1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus
EN 60966-2-6:2017 Radio frequency and coaxial cable assemblies - Part 2-6: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-24 connectors
EN 50083-2:2012/A1:2015 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 2: ELECTROMAGNETIC COMPATIBILITY FOR EQUIPMENT
IEC 61169-24:2009 Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 Ω cable networks (type F)
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 50529-2:2010 EMC Network Standard - Part 2: Wire-line telecommunications networks using coaxial cables
EN 60728-1:2014 Cable networks for television signals, sound signals and interactive services - Part 1: System performance of forward paths
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
IEC 60966-2-5:2016 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
IEC 60966-2-4:2016 Radio frequency and coaxial cable assemblies - Part 2-4: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 3 000 MHz, IEC 61169-2 connectors
EN 60966-2-5:2017 Radio frequency and coaxial cable assemblies - Part 2-5: Detail specification for cable assemblies for radio and TV receivers - Frequency range 0 MHz to 1 000 MHz, IEC 61169-2 connectors
EN 61169-2:2007 Radio-frequency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52
IEC 60728-1:2014 Cable networks for television signals, sound signals and interactive services - Part 1: System performance of forward paths
IEC 61169-2:2007 Radio-frenquency connectors - Part 2: Sectional specification - Radio frequency coaxial connectors of type 9,52
EN 61169-24:2009 Radio-frequency connectors - Part 24: Sectional specification - Radio frequency coaxial connectors with screw coupling, typically for use in 75 ohm cable networks (type F)
EN 55016-1-1:2010/A2:2014 SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014)

View more information
US$261.13
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.