• There are no items in your cart

BS EN 50124-1:2017

Current

Current

The latest, up-to-date edition.

Railway applications. Insulation coordination Basic requirements. Clearances and creepage distances for all electrical and electronic equipment

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2017

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Basis for insulation coordination
5 Requirements and dimensioning rules for clearances
6 Dimensioning rules for creepage distances
7 Tests and measurements
8 Specific requirements for applications in the
  railway field
Annex A (normative) - Tables
Annex B (normative) - Provisions for type and routine
        dielectric tests for equipment
Annex C (normative) - Methods of measuring creepage
        distances and clearances
Annex D (normative) - Correlation between U[n] and U[Nm]
Annex E (informative) - Macro-environmental conditions
Annex F (informative) - Application guide
Annex ZZ (informative) Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 2008/57/EC
Bibliography

Defines insulation coordination in railways. Pertains to equipment for use in signalling, rolling stock and fixed installations.

This European Standard deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations. Insulation coordination is concerned with the selection, dimensioning and correlation of insulation both within and between items of equipment. In dimensioning insulation, electrical stresses and environmental conditions are taken into account. For the same conditions and stresses, these dimensions are the same. An objective of insulation coordination is to avoid unnecessary over dimensioning of insulation. This standard specifies: requirements for clearances and creepage distances for equipment; general requirements for tests pertaining to insulation coordination. The term equipment relates to a section as defined in 3.3 it may apply to a system, a sub-system, an apparatus, a part of an apparatus, or a physical realization of an equipotential line. This standard does not deal with: distances through solid or liquid insulation; distances through gases other than air; distances through air not at atmospheric pressure; equipment used under extreme conditions. Product standards should align with this generic standard. However, they may require, with justification, different requirements due to safety and/or reliability reasons, e.g. for signalling, and/or particular operating conditions of the equipment itself, e.g. overhead contact lines which should comply with EN50119 . This standard also gives provisions for dielectric tests (type tests or routine tests) on equipment (see AnnexB). NOTE For safety critical systems, specific requirements are needed. These requirements are given in the product specific signalling standard EN50129 .

Committee
GEL/9
DevelopmentNote
Supersedes 93/209659 DC (01/2004) Supersedes 15/30298489 DC. (03/2017)
DocumentType
Standard
Pages
58
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
EN 50153 : 2014 AMD 1 2017 RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
IEC 60660:1999 Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 000 V up to but not including 300 kV
2008/57/EC : 2008 AMD 5 2014 DIRECTIVE 2008/1957/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 17 JUNE 2008 ON THE INTEROPERABILITY OF THE RAIL SYSTEM WITHIN THE COMMUNITY (RECAST) (TEXT WITH EEA RELEVANCE)
EN 60660:1999 Insulators - Tests on indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
EN 60383-1:1996/A11:1999 INSULATORS FOR OVERHEAD LINES WITH A NOMINAL VOLTAGE ABOVE 1 KV - CERAMIC OR GLASS INSULATOR UNITS FOR A.C. SYSTEMS - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
EN 60099-1:1994/A1:1999 SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
EN 60947-1:2007/A2:2014 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014)
EN 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50129 : 2003 COR 2010 RAILWAY APPLICATIONS - COMMUNICATION, SIGNALLING AND PROCESSING SYSTEMS - SAFETY RELATED ELECTRONIC SYSTEMS FOR SIGNALLING
IEC 60099-1:1991+AMD1:1999 CSV Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
EN 60168:1994/A2:2000 TESTS ON INDOOR AND OUTDOOR POST INSULATORS OF CERAMIC MATERIAL OR GLASS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1KV
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
EN 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 60664-5:2007 Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 60077-1:2017 Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60664-3:2017 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
EN 60383-2:1995 Insulators for overhead lines with a nominal voltage above 1 kV - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
IEC 60168:1994+AMD1:1997+AMD2:2000 CSV Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1000 V

View more information
US$311.44
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.