European foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Service conditions
5 Rating
6 Design and construction
7 Tests
8 Rules for transport, storage, erection, operation
   and maintenance
9 Safety
10 Influence of the product on the environment
11 Information to be given with enquiries, tenders
   and orders
Bibliography

Pertains to new voltage transformers which are: - intended for use in indoor or outdoor fixed installations in tractions systems and - operated with an a.c. line voltage and frequency as specified in EN 50163.

This EN50152-3-3 is applicable to new voltage transformers which are:

  • intended for use in indoor or outdoor fixed installations in tractions systems, and

  • operated with an a.c. line voltage and frequency as specified in EN50163.

NOTE1 EN50163 specifies the a.c. traction systems 15kV 16,7Hz and 25kV 50Hz.

NOTE2 As rails of a.c. traction systems are typically connected to earth and included in the return current path, all phase to earth voltages are subject to the limits as given in EN50163. Nevertheless conductor to conductor voltages are some times higher e.g. in autotransformer systems.

Voltage transformers are mainly used with:

  • measuring instruments,

  • protective devices.

This EN50152-3-3 also applies to voltage transformers other than inductive types as far as reasonably possible. Requirements of this EN50152-3-3 have priority.

NOTE3 Combined current and voltage transformers also capacitive voltage transformers are typically not used in fixed installations in traction systems.

Committee
GEL/9/3
DevelopmentNote
Supersedes 96/214119 DC. (09/2005) Supersedes 15/30314795 DC. (07/2016)
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
I.S. EN 50152-3-3:2016 Identical
DIN EN 50152-3-3 : 2016 Identical
NEN EN 50152-3-3 : 2016 Identical
NF EN 50152-3-3 : 2017 Identical
UNE-EN 50152-3-3:2016 Identical
EN 50152-3-3:2016 Identical
SN EN 50152-3-3:2016 Identical

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
EN 50124-2:2017 Railway applications - Insulation coordination - Part 2: Overvoltages and related protection
IEC 61869-3:2011 Instrument transformers - Part 3: Additional requirements for inductive voltage transformers
EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
IEC 60050-811:1991 International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction
IEC 60050-605:1983 International Electrotechnical Vocabulary (IEV) - Part 605: Generation, transmission and distribution of electricity - Substations
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC TR 61869-102:2014 Instrument transformers - Part 102: Ferroresonance oscillations in substations with inductive voltage transformers
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
EN 61869-3 : 2011 INSTRUMENT TRANSFORMERS - PART 3: ADDITIONAL REQUIREMENTS FOR INDUCTIVE VOLTAGE TRANSFORMERS (IEC 61869-3:2011)
IEC 61869-1:2007 Instrument transformers - Part 1: General requirements
EN 61869-1:2009 Instrument transformers - Part 1: General requirements
EN 60270:2001/A1:2016 HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015)
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
IEC 60137:2017 Insulated bushings for alternating voltages above 1000 V
IEC 60050-446:1983 International Electrotechnical Vocabulary (IEV) - Part 446: Electrical relays
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems

View more information
US$160.51
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.