Foreword
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
   3.1 Terms and definitions
   3.2 Abbreviations
4 General requirements
   4.1 Conformity
   4.2 Power sources
5 Functions
   5.1 Power supply from the main power source
   5.2 Power supply from the standby power source
         (battery)
   5.3 Charger
   5.4 Faults
6 Materials, design and manufacture
   6.1 Manufacturer's declaration
   6.2 Mechanical design
   6.3 Electrical design
   6.4 Power supply interface
7 Documentation
   7.1 User's documentation
   7.2 Design documentation
8 Marking
9 Tests
   9.1 General
   9.2 Functional tests
   9.3 Test of the charger and the standby power
         source
   9.4 Environmental tests
   9.5 Cold (operational)
   9.6 Damp heat, steady state (operational)
   9.7 Impact (operational)
   9.8 Vibration, sinusoidal (operational)
   9.9 Electromagnetic Compatibility (EMC), Immunity tests
         (operational)
   9.10 (deleted)
   9.11 (deleted)
   9.12 (deleted)
   9.13 (deleted)
   9.14 Damp heat, steady state (endurance)
   9.15 Vibration, sinusoidal (endurance)
Annex A (normative) Laboratory procedure for testing compliance
         with the requirements of 5.2.1 and 5.4.c
Annex ZA (informative) Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Directives (89/106/EEC)
Bibliography

Describes requirements, methods of test and performance criteria for power supply equipment of fire detection and fire alarm systems installed in buildings.

Committee
FSH/12
DevelopmentNote
Together with BS EN 54-2 supersedes BS 5839-4(1988) Supersedes 85/38334 DC (12/2002) Supersedes 00/540035 DC (09/2003) Supersedes 03/110056 DC (11/2006)
DocumentType
Standard
Pages
30
PublisherName
British Standards Institution
Status
Current
Supersedes

07/30160342 DC : 0 BS 7273-3 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 3: ELECTRICAL ACTUATION OF PRE-ACTION WATERMIST AND SPRINKLER SYSTEMS
12/30260280 DC : 0 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DOMESTIC PREMISES
03/119007 DC : DRAFT DEC 2003 BS 5839-6 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 6: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION AND MAINTENANCE OF FIRE DETECTION AND FIRE ALARM SYSTEMS IN DWELLINGS
BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
BS 5839-9:2003 Fire detection and alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS 5839-9:2011 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems
12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
12/30258581 DC : 0 BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS
BS 5839-8:1998 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning, and maintenance of voice alarm systems
BIP 2081 : 2012 A GUIDE TO EMERGENCY LIGHTING
06/30133094 DC : DRAFT OCT 2006 BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
BS 5839-8:2008 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS 5839-8:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of voice alarm systems
BS 7273-3:2008 Code of practice for the operation of fire protection measures Electrical actuation of pre-action watermist and sprinkler systems
BS 7273-1:2006 Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems
BS 7273-1:2000 Code of practice for the operation of fire protection measures Electrical actuation of gaseous total flooding extinguishing systems
PD 6531:2010 Queries and interpretations on BS 5839-1
07/30160345 DC : 0 BS 7273-5 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 5: ELECTRICAL ACTUATION OF WATERMIST SYSTEMS
BS 5908-2:2012 Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations
BS 7273-5:2008 Code of practice for the operation of fire protection measures Electrical actuation of watermist systems (except pre-action systems)
BS 7273-4:2007 Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS PAS 95(2011) : 2011 HYPOXIC AIR FIRE PREVENTION SYSTEMS - SPECIFICATION
EEMUA 138 : 2010 DESIGN AND INSTALLATION OF ON-LINE ANALYSER SYSTEMS
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
01/540647 DC : DRAFT MAY 2001 BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE
07/30136498 DC : 0 BS 5839-8 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 8: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND SERVICING OF VOICE ALARM SYSTEMS
01/540648 DC : DRAFT MAY 2001 BS 5839-9 FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 9: CODE OF PRACTICE FOR EMERGENCY VOICE COMMUNICATION SYSTEMS
12/30258718 DC : 0 BS 5839-8 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 8: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF VOICE ALARM SYSTEMS
PD 7974-4:2003 Application of fire safety engineering principles to the design of buildings Detection of fire and activation of fire protection systems. (Sub-system 4)
09/30187281 DC : 0 BS 5839-9 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 9: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF EMERGENCY VOICE COMMUNICATION SYSTEMS
BS 7273-3:2000 Code of practice for the operation of fire protection measures Electrical actuation of pre-action sprinkler systems
BS 5839-6:2004 Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings

93/68/EEC : 1993 AMD 2 1998 COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC
ENV 50142 : 1994 ELECTROMAGNETIC COMPATIBILITY - BASIC IMMUNITY STANDARD - SURGE IMMUNITY TESTS
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60950:1999 Safety of information technology equipment
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60801-4:1988 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
IEC 60817:1984 Spring-operated impact-test apparatus and its calibration
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 9001:2015 Quality management systems — Requirements
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60801-3:1984 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60801-2:1991 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

View more information
US$237.18
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.