• There are no items in your cart

BS EN 60939-2:2005

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Passive filter units for electromagnetic interference suppression Sectional specification: passive filter units for which safety tests are appropriate. Test methods and general requirements
Available format(s)

Hardcopy , PDF

Withdrawn date

09-28-2023

Language(s)

English

Published date

08-31-2006

1 General
  1.1 Scope
  1.2 Normative references
  1.3 Information to be given in a detail specification
      1.3.1 General
      1.3.2 Outline drawing and dimensions
      1.3.3 Mounting
      1.3.4 Ratings and characteristics
      1.3.5 Marking
  1.4 Terms and definitions
  1.5 Marking
      1.5.1 IEC 60939-1 with the following details:
      1.5.2 The filter shall be clearly marked with the
            information in 1.5.1 a), b), c) and d), and also e)
            if this is not implied by b)
      1.5.3 The package containing the filter(s) shall be
            clearly marked with all the information listed
            in 1.5.1
      1.5.4 Any additional marking shall be so applied that no
            confusion can arise
2 Preferred ratings and characteristics
  2.1 Preferred characteristics
      2.1.1 General
      2.1.2 Preferred climatic categories
  2.2 Preferred values of ratings
      2.2.1 Rated voltage (U[R])
      2.2.2 Category voltage (U[C])
      2.2.3 Rated temperature
      2.2.4 Passive flammability
3 Quality assessment procedures
  3.1 Primary stage of manufacture
  3.2 Structurally similar filters
  3.3 Certified records of released lots
  3.4 Approval testing
      3.4.1 Safety tests only approval
      3.4.2 Qualification approval
      3.4.3 Sampling
      3.4.4 Tests
  3.5 Quality conformance inspection
      3.5.1 General
      3.5.2 Formation of inspection lots
      3.5.3 Test schedule
      3.5.4 Delayed delivery
4 Test and measurement procedures
  4.1 Earth inductors incorporated in filters
  4.2 Capacitance and tan delta measurements
  4.3 Visual examination and check of dimensions
       4.3.1 General
       4.3.2 Creepage distances and clearances
  4.4 Voltage proof
       4.4.1 Test circuit for d.c. tests
       4.4.2 Applied voltage
       4.4.3 Requirements
  4.5 Insulation resistance
       4.5.1 Temperature correction
       4.5.2 Requirements
  4.6 DC line resistance or voltage drop at rated current
       4.6.1 DC line resistance
       4.6.2 Voltage drop at rated current
  4.7 Insertion loss
  4.8 Discharge resistance
  4.9 Robustness of terminations
  4.10 Resistance to soldering heat
       4.10.1 Test conditions
       4.10.2 Intermediate inspection, measurements and
              requirements
  4.11 Solderability
       4.11.1 Test conditions
       4.11.2 Requirements
  4.12 Rapid change of temperature
       4.12.1 Intermediate inspection
  4.13 Vibration
       4.13.1 Test conditions
       4.13.2 Intermediate inspection
  4.14 Bump
       4.14.1 Test conditions
       4.14.2 Intermediate inspection, measurements and
              requirements
  4.15 Shock
       4.15.1 Test conditions
       4.15.2 Intermediate inspection, measurements and
              requirements
  4.16 Container sealing
       4.16.1 Test conditions
       4.16.2 Requirements
  4.17 Climatic sequence
       4.17.1 Initial measurements
       4.17.2 Dry heat
       4.17.3 Damp heat, cyclic, first cycle
       4.17.4 Cold
       4.17.5 Low air pressure
       4.17.6 Damp heat, cyclic, remaining cycles
       4.17.7 Final inspection, measurements and requirements
  4.18 Damp heat, steady state
       4.18.1 Test conditions
       4.18.2 Final inspection, measurements and requirements
  4.19 Temperature rise
       4.19.1 Test method
       4.19.2 Requirements
  4.20 Impulse voltage
       4.20.1 Initial measurements
       4.20.2 Test conditions
       4.20.3 Requirements
  4.21 Endurance
       4.21.1 Test conditions - current test
       4.21.2 Test conditions - voltage test, terminations/case
       4.21.3 Test conditions - voltage test between terminations
       4.21.4 Test conditions - combined voltage/current tests
       4.21.5 Final inspection, measurements and requirements
  4.22 Charge and discharge
       4.22.1 Initial measurements
       4.22.2 Test conditions
       4.22.3 Final measurements and requirements
  4.23 Passive flammability
       4.20.2 Test conditions
       4.20.3 Requirements
  4.24 Current overload
  4.25 Solvent resistance of the marking
  4.26 Component solvent resistance
  4.27 Active flammability
Annex A (normative) Test schedule for qualification approval -
                    Assessment level D/DZ
Annex B (normative) Test schedule for safety requirements only
Annex C (normative) Circuit for the impulse voltage test
Annex D (normative) Circuit for the endurance test
Annex E (normative) Declaration of design
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Figures
Tables

Applicable to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification IEC 60939-1.

Committee
W/-
DevelopmentNote
Supersedes BS EN 133200 & 03/101948 DC. (09/2005)
DocumentType
Standard
Pages
50
PublisherName
British Standards Institution
Status
Withdrawn
Supersedes

Standards Relationship
IEC 60939-2:2005/COR1:2005 Identical
EN 62011-3-1:2003 Identical
IEC 60939-2:2005 Identical
NBN EN 60939-2 : 2006 Identical
DIN EN 60939-2 : 2006 Identical
NF EN 60939-2 : 2005 Identical
EN 60939-2:2005 Identical

EN 60939-1:2010 PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60085:2008 Electrical insulation - Thermal evaluation and designation
EN 60938-1:1999/A1:2007 FIXED INDUCTORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - PART 1: GENERIC SPECIFICATION
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60939-1:2010 Passive filter units for electromagnetic interference suppression - Part 1: Generic specification
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
IEC 60384-9:2015 Fixed capacitors for use in electronic equipment - Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60938-1:1999+AMD1:2006 CSV Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification
IEC 60940:2015 Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression
EN 60068-2-17:1994 Environmental testing - Part 2: Tests - Test Q: Sealing
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 60062:2016 Marking codes for resistors and capacitors
EN 60062:2016/AC:2016-12 MARKING CODES FOR RESISTORS AND CAPACITORS (IEC 60062:2016/COR1:2016)
EN 61140:2016 Protection against electric shock - Common aspects for installation and equipment
EN 60335-1:2012/A13:2017 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED)
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment

View more information
US$294.67
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.