• There are no items in your cart

BS EN 61347-2-7:2012

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Lamp controlgear Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
Available format(s)

Hardcopy , PDF

Superseded date

08-12-2019

Language(s)

English

Published date

03-31-2012

IEC 61347-2-7:2011 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes. It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598-2-22. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. Significant changes introduced into this third edition include:
- modification of IEC 61347-2-7 to become a standard exclusively for d.c. battery supplied electronic controlgear for emergency lighting (self-contained) IEC 61347-2-3 Annex J is intended to cover centrally supplied emergency controlgear;
- update of Clause 22 - Recharging devices;
- modification of Clause 20 battery voltage characterisation to support EBLF measurement. This to simplify and increase reproducibility of testing;
- rationalisation of requirements between IEC 61347-2-7 and IEC 60598-2-22 requirements of IEC 60598-2-22 being transferred to IEC 61347-2-7.

This publication is to be read in conjunction with IEC 61347-1:2007.

Committee
CPL/34/3
DevelopmentNote
Supersedes 98/263275 DC (10/2003) Together with 61347-1, -2-4, -2-5 and -2-6, it supersedes BS EN 60924. Supersedes 03/320435 DC (02/2007) Supersedes 08/30187424 DC. (03/2012)
DocumentType
Standard
Pages
40
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 5266-1:2016 Emergency lighting Code of practice for the emergency lighting of premises
BIP 2081 : 2012 A GUIDE TO EMERGENCY LIGHTING

IEC 61347-2-3:2011+AMD1:2016 CSV Lamp control gear - Part 2-3: Particular requirements for a.c. and/or d.c. supplied electronic control gear for fluorescent lamps
IEC 62034:2012 Automatic test systems for battery powered emergency escape lighting
IEC 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
EN 61558-2-16:2009/A1:2013 SAFETY OF TRANSFORMERS, REACTORS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS FOR SUPPLY VOLTAGES UP TO 1 100 V - PART 2-16: PARTICULAR REQUIREMENTS AND TESTS FOR SWITCH MODE POWER SUPPLY UNITS AND TRANSFORMERS FOR SWITCH MODE POWER SUPPLY UNITS (IEC 61558-2-16:2009/A1:2013)
EN 61558-1:2005/A1:2009 SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS
IEC 61558-2-16:2009+AMD1:2013 CSV Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-16: Particularrequirements and tests for switch mode power supply units andtransformers for switch mode power supply units
IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
EN 60929:2011/A1:2016 AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 61347-2-3:2011/A1:2017 LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS (IEC 61347-2-3:2011/A1:2016)
EN 60921:2004/A1:2006 BALLASTS FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
IEC 60921:2004+AMD1:2006 CSV Ballasts for tubular fluorescent lamps - Performance requirements
IEC 61558-1:2017 Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
EN 61558-2-1:2007 Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
EN 60901:1996/A6:2017 SINGLE-CAPPED FLUORESCENT LAMPS - PERFORMANCE SPECIFICATIONS (IEC 60901:1996/A6:2014, MODIFIED)
EN 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
EN 60598-2-22:2014/AC:2016-09 LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING (IEC 60598-2-22:2014/COR2:2016)
EN 62034:2012 Automatic test systems for battery powered emergency escape lighting

View more information
US$261.13
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.