• There are no items in your cart

BS EN 61966-3:2000

Current
Current

The latest, up-to-date edition.

Multimedia systems and equipment. Colour measurement and management Equipment using cathode ray tubes
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

09-15-2000

1 Scope
2 Normative references
3 Terms and definitions
4 Letters and symbols
5 Conditions
      5.1 Environmental conditions
      5.2 Conditions for measurements
      5.3 Input digital data
6 Measurement equipment
      6.1 Spectroradiometer
      6.2 Colorimeter
7 Spectral characteristics and intensity of the
      primaries and white stimuli
      7.1 Characteristics to be measured
      7.2 Measurement conditions
      7.3 Method of measurement
      7.4 Presentation of results
8 Basic colorimetric characteristics
      8.1 Characteristics to be measured
      8.2 Method of measurement
      8.3 Presentation of results
9 Tone characteristics
      9.1 Characteristics to be measured
      9.2 Measurement conditions
      9.3 Method of measurement
      9.4 Presentation of results
10 Inter-channel dependency
      10.1 Characteristics to be measured
      10.2 Measurement conditions
      10.3 Method of measurement
      10.4 Presentation of results
11 Spatial non-uniformity
      11.1 Characteristics to be measured
      11.2 Measurement conditions
      11.3 Method of measurement
      11.4 Presentation of results
12 Temporal stability
      12.1 Short-term stability
             12.1.1 Characteristics to be measured
             12.1.2 Measurement conditions
             12.1.3 Method of measurement
             12.1.4 Presentation of results
      12.2 Mid-term instability
             12.2.1 Characteristics to be measured
             12.2.2 Measurement conditions
             12.2.3 Method of measurement
             12.2.4 Presentation of results
13 Surface reflection
      13.1 Characteristics to be measured
      13.2 Measurement conditions
      13.3 Method of measurement
      13.4 Presentation of results
14 Internal flare
      14.1 Characteristics to be measured
      14.2 Measurement conditions
      14.3 Method of measurement
      14.4 Presentation of results
Figure 1 - Equipment arrangement for non-contact measurements
Figure 2 - Equipment arrangement for contact measurements
Figure 3 - Size of a colour patch
Figure 4 - An example of the spectral radiance distributions;
           r(l), g(l), and b(l)
Figure 5 - Measured points and estimated non-linear curves on
           linear and log-log scales
Figure 6 - Measurement points for spatial non-uniformity
Figure 7 - Example plots for short-term stability
Figure 8 - Example plots for mid-term stability
Figure 9 - Equipment arrangement
Table 1 - Input data for peak primaries and white
Table 2 - Example of reporting form for colours in maximum
          excitations
Table 3 - Example of reporting form
Table 4 - An example of calculated parameters and
          normalisation factors
Table 5 - An example set of basic data for tone
          characteristics
Table 6 - Digital inputs to generate colour patches for
          measurement of inter-channel dependency
Table 7 - Example of normalised tristimulus values (the
          matrix A)
Table 8 - Example of reporting form
Table 9 - Example of reporting form
Table 10 - An example of colorimetric change
Table A.1 - Types of instruments
Annex A (normative) Required colorimetric instruments
Annex B (normative) Alternative method of measurement of
                    surface reflection
Annex C (informative) Evaluation of effect of external light
                      source
Annex D (informative) Evaluation of internal and external
                      flare
Bibliography
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Deals with equipment using cathode ray tubes (CRT) to display colour images for use in multimedia applications. Contains methods and parameters for colour measurements and management for use in multimedia systems and equipment applies to the assessment of colour reproduction. Does not include colour control within equipment, nor does it specify limiting values for various parameters.

Deals with equipment using cathode ray tubes (CRT) to display colour images in multimedia applications. Defines input test signals, measurement conditions and methods of measurement, to make possible the colour management and comprehensive comparison of the results of the measurements.

Committee
EPL/100
DevelopmentNote
Also numbered as IEC 61966-3. Supersedes 98/233058 DC. (05/2005)
DocumentType
Standard
Pages
38
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
NF EN 61966-3 : 2000 Identical
I.S. EN 61966-3:2000 Identical
EN 61966-3:2000 Identical
DIN EN 61966-3:2000-10 Identical
UNE-EN 61966-3:2001 Identical
SN EN 61966-3 : 2000 Identical
NBN EN 61966-3 : 2001 Identical

IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
ISO/CIE 10527:1991 CIE standard colorimetric observers
ISO 5-4:2009 Photography and graphic technology Density measurements Part 4: Geometric conditions for reflection density
ISO/CIE 10526:1999 CIE standard illuminants for colorimetry
ISO 9241-8:1997 Ergonomic requirements for office work with visual display terminals (VDTs) Part 8: Requirements for displayed colours

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.