Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Seismic design objectives and performance criteria
6 Sources of seismic demand on NSCS
7 General conditions for determining seismic demand
   on NSCS
8 Quantification of elastic seismic demand on NSCS
9 Verification of NSCS
10 Verification of seismic load path between NSCS and
   building structural system
11 Quality assurance and enforcement
Annex A (informative) - Identification of NSCS requiring
        seismic evaluation
Annex B (informative) - Principles for choosing importance
        factors for NSCS
Annex C (informative) - Principles for choosing the floor
        response amplification factor (height factor)
Annex D (informative) - Principles for choosing the
        component amplification factor (resonance factor)
Annex E (informative) - Principles for determining response
        modification factors
Annex F (informative) - Principles for determining seismic
        relative displacements for drift-sensitive components
Annex G (informative) - Floor response spectra
Annex H (informative) - Methods for verifying NSCS by
        design analysis
Annex I (informative) - NSCS verification by shake table
        testing
Annex J (informative) - NSCS verification through use of
        experience data
Annex K (informative) - Principles of seismic anchorage
        of NSCS
Annex L (informative) - Quality assurance in design and
        construction
Bibliography

Specifies the means to derive seismic actions on nonstructural components and systems (NSCS) supported by or attached to new or existing buildings.

1.1General This International Standard establishes the means to derive seismic actions on nonstructural components and systems (NSCS) supported by or attached to new or existing buildings. It also provides procedures for the verification of NSCS seismic capacities. NSCS include architectural elements, mechanical and electrical systems, and building contents. This International Standard is not a legally binding and enforceable code. It is a source document that is utilized in the development of codes of practice by the competent authority responsible for issuing structural design regulations. This International Standard is intended for application by regional and national standards committees when preparing standards for the seismic performance of NSCS. This International Standard does not specifically cover industrial facilities, including nuclear power plants, since these are dealt with separately in other International Standards. However, the principles in this International Standard can be appropriate for the derivation of seismic actions for NSCS in such facilities. NOTE 1 This International Standard has been prepared mainly for NSCS associated with engineered buildings. The principles are, however, applicable to non-engineered buildings. NOTE 2 Procedures for the verification of the supporting building structure for gravity and seismic actions applied by the NSCS are outside the scope of this International Standard and are provided in ISO3010. 1.2 Relationship with ISO3010 This International Standard is a companion document to ISO3010, Basis for design of structures— Seismic actions on structures. ISO3010 and its annexes provide basic seismic design criteria to be used in the design of structures but they do not provide design criteria for NSCS (except for those that can influence the structural response). For consistency, the terms and definitions that are in common with ISO3010 are also used in this International Standard. The same ground motion criteria specified in ISO3010 are also used in this International Standard. The demand on NSCS is directly related to the response of the building in which they are located. Therefore, the procedures used to determine the design ground motion and building seismic response are directly referenced by this International Standard. 1.3 Components requiring evaluation Evaluation of NSCS for seismic actions is required where any of the following apply: the NSCS poses a falling hazard; the failure of the NSCS can impede the evacuation of the building; the NSCS contains hazardous materials; the NSCS is necessary to the continuing function of essential facilities after the event; and damage to the NSCS represents a significant financial loss. Guidance for identification of NSCS that require seismic evaluation is provided in AnnexA. NOTE Pre-assembled modular mechanical and electrical units (e.g. heating and cooling modules) may be treated as an assembly of components supported by the modular unit housing structure (see 9.5). 1.4 Components excluded The requirements of this International Standard are not intended for application to furnishings, or temporary or relocatable components (see AnnexA). With the exception of parapets (as described in AnnexA), application of this International Standard to components in buildings subject to low levels of seismic hazard may not be warranted.

Committee
B/525/1
DevelopmentNote
Supersedes 12/30238878 DC. (12/2013)
DocumentType
Standard
Pages
54
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 13033:2013 Identical

ISO 3010:2017 Bases for design of structures — Seismic actions on structures
ISO 2394:2015 General principles on reliability for structures

View more information
US$330.61
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.