• There are no items in your cart

PD 60079-14:2000

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Guide to application of BS EN 60079-14

Available format(s)

Hardcopy , PDF

Withdrawn date

07-01-2007

Language(s)

English

Published date

01-15-2000

Foreword to PD 60079-14
Foreword
Introduction
1 Scope and object
2 Normative references
3 Definitions and terms [see IEC 50(426)]
4 General
      4.1 General requirements
      4.2 Documentation
5 Selection of electrical apparatus (excluding cables
      and conduits)
      5.1 Specific information
      5.2 Selection according to zones
      5.3 Selection according to the ignition temperature
             of the gas or vapour
      5.4 Selection according to apparatus grouping
      5.5 External influences
6 Protection from dangerous (incendive) sparking
      6.1 Danger from live parts
      6.2 Danger from exposed and extraneous conductive
             parts
      6.3 Potential equalization
      6.4 Static electricity
      6.5 Lightning protection
      6.6 Electromagnetic radiation
      6.7 Cathodically protected metallic parts
7 Electrical protection
8 Emergency switch-off and electrical isolation
      8.1 Emergency switch-off
      8.2 Electrical isolation
9 Wiring systems
      9.1 General
      9.2 Cable systems for Zone 0
      9.3 Cable systems for Zones 1 and 2
      9.4 Conduit systems
10 Additional requirements for type of protection "d"
      - Flameproof enclosures
      10.1 Solid obstacles
      10.2 Protection of flameproof joints
      10.3 Cable entry systems
      10.4 Motors supplied at varying frequency and
             voltage
      10.5 Conduit systems
11 Additional requirements for type of protection "e"
      - Increased safety
      11.1 Degree of production of enclosures (IEC 34-5
             and IEC 529)
      11.2 Cage induction motors - Thermal protection in
             operation
      11.3 Wiring systems
      11.4 Resistance heating devices
12 Additional requirements for type of protection "i"
      - Intrinsic safety
      12.1 Introduction
      12.2 Installation for Zones 1 and 2
      12.3 Installations for Zone 0
13 Additional requirements for type of protection "p"
      - Pressurized apparatus
      13.1 Ducting
      13.2 Actions to be taken on failure of
             pressurization
      13.3 Multiple pressurized enclosures with a common
             safety device
      13.4 Purging
14 Additional requirements for apparatus for use in
      Zone 2
      14.1 Degree of protection of enclosures (IEC 34-5
             and IEC 529)
      14.2 Energy-limited apparatus and circuits
      14.3 Wiring systems
      14.4 Motors supplied at varying frequency and voltage
15 Special applications (additional clause)
      15.1 Battery operated vehicles
      15.2 Personal electrical apparatus
Annex A (normative) Verification of intrinsically safe
                    circuits with more than one associated
                    apparatus with linear current/voltage
                    characteristics
Annex B (informative) Methods of determining the maximum
                      system voltages and currents in
                      intrinsically safe circuits with more
                      than one associated apparatus with
                      linear current/voltage characteristics
                      (as required by Annex A)
Annex C (informative) Frictional sparking risks with light
                      metals and their alloys
Annex D (informative) Determination of cable parameters
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications
Bibliography

Gives requirements for design, selection and erection of electrical installations in explosive gas atmospheres, which are in addition to requirements for installations in non-hazardous areas. Applicable to all electrical equipment and installations in hazardous areas whether, temporary, permanent, portable, transportable or hand-held. Applicable to installations at all voltages.

Committee
EXL/31/3
DocumentType
Standard
Pages
60
PublisherName
British Standards Institution
Status
Withdrawn

DEFSTAN 00-101(PT3)/2(2008) : 2008 DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION
EI TP PETROLEUM ROAD TANKER : 2010 PETROLEUM ROAD TANKER DESIGN AND CONSTRUCTION
EI MODEL CODE SAFE PRACTICE PT1 : 2010 THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS

IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 60614-2-5:1992 Specifications for conduits for electrical installations - Part 2: Particular specifications for conduits - Section 5: Flexible conduits
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60755:2017 General safety requirements for residual current operated protective devices
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"

View more information
US$330.61
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.