Guidance for the provision of Alarm Transmission Systems (ATS) for Alarm Systems in the UK
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

06-29-2017

Foreword
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General considerations
5 ATS categories
6 RCT to AMS reporting
7 SPT to AS reporting
8 ATS availability
Annex A (informative) - Installation guidance for
        intruder and hold-up alarm application
Annex B (informative) - Additional requirements to
        BS EN 50136-1
Annex C (informative) - Hosted RCT
Bibliography

Defines guidance and recommendations relating to alarm transmission systems used in association with alarm systems.

This Published Document provides guidance and recommendations relating to alarm transmission systems used in association with alarm systems.

NOTE1 Alarm transmission systems (ATS) provide a means of sending alarm messages (such as fire, intrusion, access control or social alarm) away from the supervised premises to an alarm receiving centre.

This Published Document builds upon the existing BSEN50136series for alarm transmission systems by providing additional guidance, such as additional ATS performance categories and actions to be taken when the availability fails to meet the required levels, alongside fitting and installation advice to improve the security and reliability of ATS.

NOTE2 See Annex A for installation guidance for intruder and hold-up alarm application.

This Published Document also includes recommendations to enable enhanced reporting of dual path failures.

Committee
GW/1/5
DevelopmentNote
Supersedes 17/30356170 DC. (07/2017)
DocumentType
Standard
Pages
18
PublisherName
British Standards Institution
Status
Current
Supersedes

BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises

BS EN 50131-1 : 2006 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
BS EN 50131-10:2014 Alarm systems. Intrusion and hold-up systems Application specific requirements for Supervised Premises Transceiver (SPT)
DD CLC/TS 50131-7:2010 Alarm systems. Intrusion and hold-up systems Application guidelines
BS EN 50136-1 : 2012 ALARM SYSTEMS - ALARM TRANSMISSION SYSTEMS AND EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR ALARM TRANSMISSION SYSTEMS
BS 8591:2014 Remote centres receiving signals from alarm systems. Code of practice
BS 8243(2010) : 2010 INSTALLATION AND CONFIGURATION OF INTRUDER AND HOLD-UP ALARM SYSTEMS DESIGNED TO GENERATE CONFIRMED ALARM CONDITIONS - CODE OF PRACTICE

View more information
US$160.51
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.