• There are no items in your cart

CEI 20-56 : 2010

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO
Available format(s)

Hardcopy , PDF

Superseded date

12-21-2023

Language(s)

English

Published date

01-01-2010

FASC 10658 La presente norma riguarda le prescrizioni relative ai cavi con isolamento estruso per tensioni nominali da 3,6/6 (7,2) kV a 20,8/36 (42) kV; i cavi oggetto di questa norma sono utilizzati nei sistemi di distribuzione dell'energia.

Committee
CT 20
DocumentType
Standard
Pages
120
PublisherName
Comitato Elettrotecnico Italiano
Status
Superseded
SupersededBy

Standards Relationship
HD 620 : 2010 Identical

CEI 20-62/2 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION
CEI 20-62/1 : 2006 TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION
CEI 20-89 : 2009 SELECTION AND ERECTION OF MEDIUM VOLTAGE ELECTRIC CABLES AND ACCESSORIES - APPLICATION CRITERIA

HD 632 : 1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
IEC 60228:2004 Conductors of insulated cables
CEI 20-66 : 2010 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
HD 405.1 : S1 AMD 1 TESTS ON ELECTRIC CABLES UNDER FIRE CONDITIONS - TEST ON A SINGLE VERTICAL INSULATED WIRE OR CABLE
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
IEC 60502:1994 Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV
CEI 20-50 : 2010 ELECTRICAL CABLES ADDITIONAL TEST METHODS
CEI EN 60229 : 2010 ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
EN 60332-1-2:2004/A11:2016 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015)
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
HD 48 : 200S1 IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
CEI EN 60228 : 2005 CONDUCTORS OF INSULATED CABLES
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
EN 60885-3:2015 Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
HD 186 : S2 AMD 1 MARKING BY INSCRIPTION FOR THE IDENTIFICATION OF CORES OF ELECTRIC CABLES HAVING MORE THAN 5 CORES
EN 60230:2002 Impulse tests on cables and their accessories
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
CEI 20-29 : 2ED 1997
EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame

View more information
US$214.69
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.