• There are no items in your cart

CLSI MM3 P2 : 2ED 2005

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

MOLECULAR DIAGNOSTIC METHODS FOR INFECTIOUS DISEASES

Superseded date

02-17-2006

Published date

01-12-2013

Abstract
Committee Membership
Foreword
1 Scope
2 Introduction
3 Standard Precautions
4 Terminology
   4.1 Definitions
   4.2 Abbreviations and Acronyms
5 Applications
   5.1 Utility of Molecular Diagnostic Tests
   5.2 Screening or Initial Testing
   5.3 Confirmatory and Supplemental Testing
6 Specimen Collection, Transport, and Processing
7 Contributors to False Negatives and Controls
   7.1 Detection of Inhibitors and Interfering
         Substances
   7.2 Inhibitory Samples
8 Methods
   8.1 Physical and Chemical Methods for Nucleic
         Acid Detection
   8.2 Detection Formats
   8.3 Nucleic Acid Amplification Technologies
   8.4 Real-Time PCR Instruments
9 Selection and Qualification of Nucleic Acid Sequences
   9.1 Target Region
   9.2 PCR Primer Sequence Selection
   9.3 Hybridization Probe Sequence Selection
   9.4 Fluorescent Resonance Energy Transfer (FRET)
         Probes
   9.5 Probe and Primer Forms and Purity
10 Establishment and Evaluation of Performance Characteristics
   of Molecular Diagnostic Tests
   10.1 Limit of Detection (Analytical Sensitivity)
   10.2 Analytical Specificity
   10.3 Precision
   10.4 Cutoff Values
   10.5 Diagnostic Sensitivity
   10.6 Diagnostic Specificity
   10.7 Predictive Values
   10.8 Diagnostic Accuracy
   10.9 Diagnostic Value
   10.10 Test Limitations
   10.11 Implementation of FDA-Cleared Tests
11 Quality Assurance
   11.1 Laboratory Design and Practices
   11.2 Instruments
   11.3 Quality Assurance (QA) During Development of Molecular
         Diagnostic Tests
   11.4 Control Materials
   11.5 Selecting Organism Strains for Analytical Studies
   11.6 Preparing Nucleic Acid Controls
   11.7 Types of Testing During Assay Development
   11.8 Quality Assurance (QA) for Implementation of Molecular
         Diagnostic Tests
12 Proficiency Testing
13 Controlling False-Positive Nucleic Acid Target Amplification
   Reactions
   13.1 Reagents and Solutions
   13.2 Laboratory Practice
   13.3 Selection and Preparation of Controls
   13.4 Amplification Product Inactivation Methods
14 Reporting of Results
   14.1 Organism and Nucleic Acid Target
   14.2 Equivocal Results
   14.3 Reference Range
   14.4 Critical Results
   14.5 Test Limitations
   14.6 Interpretation
   14.7 Clarifying Statements
15 Recommendations for Manufacturers and Clinical Laboratories
   15.1 Regulatory Requirements
   15.2 Recommendations to Assay Developers
   15.3 Recommendations for Clinical Laboratories
   15.4 Selection of Referral Laboratories
References
Additional References
Appendix A. Nucleic Acid Amplification Technologies
Summary of Consensus Comments and Subcommittee Responses
The Quality System Approach
Related CLSI/NCCLS Publications

Describes the clinical applications, amplified and nonamplified nucleic acid methods, selection and qualification of nucleic acid sequences, establishment and evaluation of test performance characteristics, inhibitors, and interfering substances, controlling false-positive reactions, reporting and interpretation of results, quality assurance, regulatory issues, and recommendations for manufacturers and clinical laboratories.

DocumentType
Proposed Guideline
PublisherName
Clinical Laboratory Standards Institute
Status
Superseded
SupersededBy

CLSI MM13 A : 1ED 2006 COLLECTION, TRANSPORT, PREPARATION, AND STORAGE OF SPECIMENS FOR MOLECULAR METHODS

CLSI EP12 A : 1ED 2002 USER PROTOCOL FOR EVALUATION OF QUALITATIVE TEST PERFORMANCE
CLSI MM6 A : 1ED 2003 QUANTITATIVE MOLECULAR METHODS FOR INFECTIOUS DISEASES
CLSI MM13 P : 1ED 2005 COLLECTION, TRANSPORT, PREPARATION, AND STORAGE OF SPECIMENS FOR MOLECULAR METHODS
CLSI EP5 A2 : 2ED 2004 EVALUATION OF PRECISION PERFORMANCE OF QUANTITATIVE MEASUREMENT METHODS
CLSI GP10 A : 1ED 95(R2001) ASSESSMENT OF THE CLINICAL ACCURACY OF LABORATORY TESTS USING RECEIVER OPERATING CHARACTERISTIC (ROC) PLOTS
CLSI GP2 A4 : 4ED 2002 CLINICAL LABORATORY TECHNICAL PROCEDURE MANUALS
CLSI MM10 P : 1ED 2005 GENOTYPING FOR INFECTIOUS DISEASES: IDENTIFICATION AND CHARACTERIZATION
CLSI MM9 A : 1ED 2004 NUCLEIC ACID SEQUENCING METHODS IN DIAGNOSTIC LABORATORY MEDICINE
CLSI EP17 A : 1ED 2004 PROTOCOLS FOR DETERMINATION OF LIMITS OF DETECTION AND LIMITS OF QUANTITATION
CLSI GP18 A : 1ED 98 LABORATORY DESIGN

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.