• There are no items in your cart

C22.10-10

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first Edition) with Québec Amendments
Available format(s)

Hardcopy , PDF

Superseded date

05-03-2021

Language(s)

French, English

Published date

01-01-2010

Preface
The history and operation of the Canadian Electrical Code, Part I
Metric units
Reference publications
Section 0 - Object, scope, and definitions
Section 2 - General Rules
Section 4 - Conductors
Section 6 - Services and service equipment
Section 8 - Circuit loading and demand factors
Section 10 - Grounding and bonding
Section 12 - Wiring methods
Section 14 - Protection and control
Section 16 - Class 1 and Class 2 circuits
Section 18 - Hazardous locations
Section 20 - Flammable liquid and gas dispensing and service
             stations, garages, bulk storage plants, finishing
             processes, and aircraft hangars
Section 22 - Locations in which corrosive liquids, vapours, or
             excessive moisture are likely to be present
Section 24 - Patient care areas
Section 26 - Installation of electrical equipment
Section 28 - Motors and generators
Section 30 - Installation of lighting equipment
Section 32 - Fire alarm systems, fire pumps, and carbon
             monoxide alarms
Section 34 - Signs and outline lighting
Section 36 - High-voltage installations
Section 38 - Elevators, dumbwaiters, material lifts, escalators,
             moving walks, lifts for persons with physical
             disabilities, and similar equipment
Section 40 - Electric cranes and hoists
Section 42 - Electric welders
Section 44 - Theatre installations
Section 46 - Emergency power supply, unit equipment, exit
             signs, and life safety systems
Section 48 - Motion picture studios, projection rooms, film
             exchanges including film-vaults, and storehouses
             for pyroxylin plastic and nitrocellulose X-ray
             and photographic film
Section 50 - Solar photovoltaic systems
Section 52 - Diagnostic imaging installations
Section 54 - Community antenna distribution and radio and
             television installations
Section 56 - Optical fiber cables
Section 58 - Passenger ropeways and similar equipment
Section 60 - Electrical communication systems
Section 62 - Fixed electric space and surface heating systems
Section 64
Section 66 - Amusement parks, midways, carnivals, film and
             TV sets, TV remote broadcasting locations, and
             travelling shows
Section 68 - Pools, tubs, and spas
Section 70 - Electrical requirements for factory-built relocatable
             structures and non-relocatable structures
Section 72 - Mobile home and recreational vehicle parks
Section 74 - Airport installations
Section 76 - Temporary wiring
Section 78 - Marinas, yacht clubs, marine wharves, structures,
             and fishing harbours
Section 80 - Cathodic protection
Section 82 - Closed-loop and pre-closed-loop power distribution
Section 84 - Interconnection of electric power production sources
Section 86 - Electric vehicle charging systems
Appendix A - Safety standards for electrical equipment, Canadian
             Electrical Code, Part II
Appendix B - Notes on Rules
Appendix C - The Technical Committee on the Canadian Electrical
             Code, Part I - Organization and rules of procedure
Appendix D - Tabulated general information
Appendix E - Dust-free rooms
Appendix F - Recommended installation practice for intrinsically
             safe and non-incendive electrical equipment and wiring
Appendix G - Electrical installations of fire protection systems
Appendix H - Combustible gas detection instruments for use in
             Class I hazardous locations
Appendix I - Interpretations approved since publication of the
             2006 Code
Appendix J - Rules and Notes to Rules for installations using
             the Division system of classification for Class I
             locations
Appendix K - Extract from IEC 60364-1
Index

Overview The Quebec Electrical Code is comprised of the Canadian Electrical Code, Part I as adopted in the Province of Quebec. It includes Quebec provincial amendments. The Canadian Electrical Code, Part I is adopted across Canada as regulation for the installation and maintenance of electrical equipment.

Preface This twenty-first edition of the Canadian Electrical Code, Part I, was approved by the Committee on the Canadian Electrical Code, Part I, and by the Regulatory Authority Committee at their June 2008 meetings in Calgary, Alberta. This twenty-first edition supersedes the previous editions, published in 2006, 2002, 1998, 1994, 1990, 1986, 1982, 1978, 1975, 1972, 1969, 1966, 1962, 1958, 1953, 1947, 1939, 1935, 1930, and 1927. A new Section 58 was added to cover requirements for passenger ropeways and similar equipment. In addition, there are significant changes to Sections 0, 10, 18, 26, 46, and 68. Sections 12 and 32 have been revised to reflect new technology and industry practices. The designation for receptacle configuration type 5-20RA (\"T-slot\") has been revised to 5-20R throughout the Code, and the configuration previously designated as 5-20R is now designated 5-20RA to recognize that this configuration is being phased out. Similarly, the designations for 6-20R and 6-20RA configurations have been interchanged throughout the Code. The term \"light fixture\" has been replaced by \"luminaire\" throughout the Code, and all references to HFT conduit have been deleted. Scope The object of this Code is to establish safety standards for the installation and maintenance of electrical equipment. In its preparation, consideration has been given to the prevention of fire and shock hazards, as well as proper maintenance and operation. The requirements in this Code address the fundamental principles of protection for safety contained in Section 131 of International Electrotechnical Commission Standard 60364-1, Electrical Installations of Buildings. IEC 60364-1, Section 131, contains fundamental principles of protection for safety that encompass protection against electric shock, thermal effects, overcurrent, fault currents, and overvoltage. Therefore, compliance with the requirements of this Code and proper maintenance will ensure an essentially safe installation. Safe installations may be also achieved by alternatives to this Code, when such alternatives meet the fundamental safety principles of IEC 60364-1 (see Appendix K). These alternatives are intended to be used only in conjunction with acceptable means to assess compliance of these alternatives with the fundamental safety principles of IEC 60364 by the authorities enforcing this Code. Wiring installations that do not make provision for the increasing use of electricity may be overloaded in the future, resulting in a hazardous condition. It is recommended that the initial installation have sufficient wiring capacity and that there be some provision made for wiring changes that might be required as a result of future load growth. This Code is not intended as a design specification nor as an instruction manual for untrained persons. This Code covers all electrical work and electrical equipment operating or intended to operate at all voltages in electrical installations for buildings, structures, and premises, including factory-built relocatable and non-relocatable structures, and self-propelled marine vessels stationary for periods exceeding five months and connected to a shore supply of electricity continuously or from time to time, with the following exceptions: (a) installations or equipment employed by an electric, communication, or community antenna distribution system utility in the exercise of its function as a utility, as recognized by the regulatory authority having jurisdiction, and located outdoors or in buildings or sections of buildings used for that purpose; (b) equipment and facilities that are used in the operation of an electric railway and are supplied exclusively from circuits that supply the motive power; (c) installations or equipment used for railway signalling and railway communication purposes, and located outdoors or in buildings or sections of buildings used exclusively for such installations; (d) aircraft; and (e) electrical systems in ships that are regulated under Transport Canada. For mines and quarry applications, see also CAN/CSA-M421. This Code and any standards referenced in it do not make or imply any assurance or guarantee by the authority adopting this Code with respect to life expectancy, durability, or operating performance of equipment and materials so referenced.

DevelopmentNote
Also available in Package with CSA C22.1HB-2009. (12/2010)
DocumentType
Standard
Pages
0
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy
Supersedes

NFPA 820 : 2016 FIRE PROTECTION IN WASTEWATER TREATMENT AND COLLECTION FACILITIES
NFPA 91 : 2015 EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS
IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV Classification of environmental conditions - Part 1: Environmental parameters and their severities
IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
CSA C22.2 No. 157 : 1992 INTRINSICALLY SAFE AND NON-INCENDIVE EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS
API 500 : 2012 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2
ASME A17.5 : 2014 ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT
CSA C22.2 No. 25 : 1966 ENCLOSURES FOR USE IN CLASS 2, DIVISION 1, GROUPS E, F, AND G HAZARDOUS LOCATIONS
IEEE 487-2015 IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations
CSA C22.2 No. 1 : 2004 AUDIO, VIDEO AND SIMILAR ELECTRONIC EQUIPMENT
NFPA 96 : 2017 VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
CSA Z267 : 2000 SAFETY CODE FOR AMUSEMENT RIDES AND DEVICES
IEC 60079-19:2010+AMD1:2015 CSV Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
CSA C22.2 No. 77 : 2014 MOTORS WITH INHERENT OVERHEATING PROTECTION
CSA B355 : 2015 LIFTS FOR PERSONS WITH PHYSICAL DISABILITIES
NFPA 505 : 2013 FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS
IEC 61241-1-1:1999 Electrical apparatus for use in the presence of combustible dust - Part 1-1: Electrical apparatus protected by enclosures and surface temperature limitation - Specification for apparatus
IEEE 837-2014 REDLINE IEEE Standard for Qualifying Permanent Connections Used in Substation Grounding
IEC 60079-17:2013 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
IEC 60364-5-51:2005 Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules
CSA C22.2.130.1 : M90(R2001) HEAT-TRACING CABLE SYSTEMS FOR USE IN INDUSTRIAL LOCATIONS
CSA C22.2 No. 114 : 1990 DIAGNOSTIC IMAGING AND RADIATION THERAPY EQUIPMENT
CSA C22.2 No. 124 : 2016 MINERAL-INSULATED CABLE
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEC 60781:1989 Application guide for calculation of short-circuit currents in low-voltage radial systems
CSA B44.1 : 2014 ELEVATOR AND ESCALATOR ELECTRICAL EQUIPMENT
CAN/CSA-Z662-15 Oil and gas pipeline systems
CSA S413 : 2014 PARKING STRUCTURES
NFPA 496 : 2017 PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT
CSA C22.2 No. 60079.1 : 2016 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D'
IEC TR 60079-16:1990 Electrical apparatus for explosive gas atmospheres. Part 16: Artificial ventilation for the protection of analyser(s) houses
IEC 60364-1:2005 Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions
IEC 61241-3:1997 Electrical apparatus for use in the presence of combustible dust - Part 3: Classification of areas where combustible dust are or may be present
ASME A17.1-2016/CSA B44-16 Safety code for elevators and escalators (Bi-national standard, with ASME A17.1)
CSA C22.2 No. 178 : 1978 AUTOMATIC TRANSFER SWITCHES
ASME B1.20.1 : 2013(R2018) PIPE THREADS, GENERAL PURPOSE (INCH)
IEEE 835-1994 IEEE Standard Power Cable Ampacity Tables
EI Model code of safe practice Part 15:2015 MODEL CODE OF SAFE PRACTICE - PART 15: AREA CLASSIFICATION FOR INSTALLATIONS HANDLING FLAMMABLE FLUIDS
CSA C22.2 No. 60529 : 2016 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
NEMA VE 1:2017 Metal Cable Tray Systems
IEEE 80-2013 REDLINE IEEE Guide for Safety in AC Substation Grounding
NEMA WD 6 : 2016 WIRING DEVICES - DIMENSIONAL SPECIFICATIONS
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
API 505 : 1997 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2
IEEE 484-2002 IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
IEC 60079-25:2010 Explosive atmospheres - Part 25: Intrinsically safe electrical systems
CSA Z240 MH SERIES : 2016 MANUFACTURED HOMES
CSA E79.18 : 1995 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - ENCAPSULATION "M"
IEC 61241-2-3:1994 Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 3: Method for determining minimum ignition energy of dust/air mixtures
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
B52-13 Mechanical refrigeration code
NFPA 72 : 2016 NATIONAL FIRE ALARM AND SIGNALING CODE
IEC 61241-1-2:1999 Electrical apparatus for use in the presence of combustible dust - Part 1-2: Electrical apparatus protected by enclosures and surface temperature limitation - Selection, installation and maintenance
CSA C22.2 No. 130 : 2016 REQUIREMENTS FOR ELECTRICAL RESISTANCE TRACE HEATING AND HEATING DEVICE SETS
IEC 61241-4:2001 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
ISO 965-1:2013 ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data
CSA Z240 RV SERIES : 2014 RECREATIONAL VEHICLES
NFPA 51A : 2012 ACETYLENE CYLINDER CHARGING PLANTS
IEEE 1584-2002 IEEE Guide for Performing Arc Flash Hazard Calculations
IEC 61241-2-1:1994 Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures of dust
CSA C22.2 No. 107.1 : 2016 POWER CONVERSION EQUIPMENT
CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
IEC TR 60079-12:1978 Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents
CSA C22.2 No. 14 : 2013 INDUSTRIAL CONTROL EQUIPMENT
CSA Z32 : 2015 ELECTRICAL SAFETY AND ESSENTIAL ELECTRICAL SYSTEMS IN HEALTH CARE FACILITIES
NFPA 655 : 2017 PREVENTION OF SULFUR FIRES AND EXPLOSIONS
C22.2 NO. 126.1-17 Metal cable tray systems (Binational standard with NEMA VE 1-2017)
C22.2 NO. 213-17 Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations (Binational standard with UL 121201)
C282-15 Emergency electrical power supply for buildings
NFPA 20 : 2016 INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
ISA RP12.06.01 : 2003 RECOMMENDED PRACTICE FOR WIRING METHODS FOR HAZARDOUS (CLASSIFIED) LOCATIONS INSTRUMENTATION - PART 1: INTRINSIC SAFETY
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
NFPA 497 : 2017 CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
IEC 60079-4A:1970 Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975

View more information
US$175.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.