Surge protective devices - Type 1 - Permanently connected
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2017

Preface
1 Scope
2 Reference publications
3 Definitions and abbreviations
4 Construction
5 Documentation, ratings, and markings
6 Tests
Annex A (informative) - Optional additional testing information
        for surge protective devices

This Standard applies to surge protective devices (SPDs) intended for: a) permanently connected applications designed for limiting surge voltages and discharging surge currents; b) use on 50/60 Hz circuits over 42 V and up to 750 V ac; c) installation between the secondary of the service transformer and the line side of the service equipment overcurrent protective device.

Preface This is the second edition of CSA C22.2 No. 269.1, Surge protective devices - Type 1 - Permanently connected. It supersedes the previous edition published in 2014. This Standard is one in a series of standards dealing with surge protective devices. This Standard is issued by the CSA Group under Part II of the Canadian Electrical Code.? For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0.? This edition incorporates numerous changes throughout to align the requirements with the revisions and updates made to other standards in this series.? This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.? Scope 1.1 This Standard applies to surge protective devices (SPDs) intended for:? a) permanently connected applications designed for limiting surge voltages and discharging surge currents;? b) use on 50/60 Hz circuits over 42 V and up to 750 V ac;? c) installation between the secondary of the service transformer and the line side of the service equipment overcurrent protective device. These devices may also be installed on the load side of the main overcurrent protective device;? d) installation where external overcurrent protection may not be present; and? e) indoor or outdoor use in accordance with the Canadian Electrical Code, Part I.? 1.2 Type 1 SPDs intended for use in lightning protection systems are within the scope of this Standard.? 1.3 Equipment designed solely for other power disturbances such as notches, sags and noise is not within the scope of this document.? 1.4 SPDs discussed in this standard contain at least one voltage limiting or voltage switching component for diverting surge currents or dissipating surge energy, or both. Examples of such components are metal oxide varistors, silicon avalanche diodes, spark gaps and gas discharge tubes. Ferroresonators, motor- generators, uninterruptible power supplies, and filters containing only inductive or capacitive components are not considered SPDs in this standard.? 1.5 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard.? Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.? Notes to tables and figures are considered part of the table or figure and may be written as requirements.? Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

DevelopmentNote
Also available in CSA C22.2.269 PACKAGE. (09/2017)
DocumentType
Standard
ISBN
978-1-4883-0799-7
Pages
60
PublisherName
Canadian Standards Association
Status
Current
Supersedes

CSA C22.2 No. 94.1 : 2015 ENCLOSURES FOR ELECTRICAL EQUIPMENT, NON-ENVIRONMENTAL CONSIDERATIONS
CSA C22.2 No. 5 : 2013 MOLDED-CASE CIRCUIT BREAKERS, MOLDED-CASE SWITCHES AND CIRCUIT-BREAKER ENCLOSURES
C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
CSA C22.2 No. 0.4 : 2004(R2013) BONDING OF ELECTRICAL EQUIPMENT
IEEE C62.62-2010 IEEE Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low Voltage (1000 V and less) AC Power Circuits
CSA C22.2 No. 0.2 : 2016 INSULATION COORDINATION
CSA C22.2 No. 115 : 2014 METER-MOUNTING DEVICES
CSA C22.2 No. 269.5 : 2015 SURGE PROTECTIVE DEVICES - TYPE 5 - COMPONENTS
IEC 62305-1:2010 Protection against lightning - Part 1: General principles
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
CSA C22.2 No. 190 : 2014 CAPACITORS FOR POWER FACTOR CORRECTION
CSA C22.2 No. 60529 : 2016 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
C22.2 NO. 8-13 (R2018) Electromagnetic interference (EMI) filters
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
CSA C22.2 No. 127 : 2015 EQUIPMENT AND LEAD WIRES
IEC 61180-1:1992 High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements
CSA C22.2 No. 14 : 2013 INDUSTRIAL CONTROL EQUIPMENT
CSA E60384.14 : 2014 FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT - PART 14: SECTIONAL SPECIFICATION - FIXED CAPACITORS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION AND CONNECTION TO THE SUPPLY MAINS
CSA C22.2 No. 94.2 : 2015 ENCLOSURES FOR ELECTRICAL EQUIPMENT, ENVIRONMENTAL CONSIDERATIONS

View more information
US$150.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.