• There are no items in your cart

CSA C22.2 NO. 284:16 (R2020)

Current

Current

The latest, up-to-date edition.

Nonindustrial photoelectric switches for lighting control (Tri-national standard with UL 773A and NMX-J-715-ANCE)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2016

Preface This is the harmonized ANCE, CSA Group, and UL standard for Nonindustrial Photoelectric Switches for Lighting Control . It is the first edition of NMX-J-715-ANCE, the first edition of CSA-C22.2 No. 284-16, and the sixth edition of UL 773A. This edition of UL 773A supersedes the previous edition published on February 10, 2006. This harmonized standard has been jointly revised on June 26, 2020. For this purpose, CSA Group and UL are issuing revision pages dated June 26, 2020, and ANCE is issuing a new edition dated June 26, 2020. The CSA Group standard also replaces the following Technical Information Letters (T. I. L.), for products covered in this Standard: – TIL No. A-15 Photo-electric switches This standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Scope 1.1 Requirements contained in this Standard cover controls of the light-sensitive or presence-sensitive types, or both; for indoor or outdoor service; intended for the control of indoor or outdoor loads up to a maximum of 20 A and maximum 347 V; intended for installations on 50 Hz or 60 HZ systems or DC up to 60 V (for US); and DC up to 42.4 V (for Canada); and intended to be installed in accordance with the National Electrical Code (NEC), NFPA 70, the Canadian Electrical Code (CE Code) Part I, CSA C22.2 No. 0, and NOM 001 SEDE. 1.2 These requirements do not cover controls intended to be used under the following conditions: a) Devices that are locking type, used for area or roadway lighting fixtures; b) Devices that monitor or control safety critical loads or personal protection circuits; c) Devices intended to be installed in areas designated hazardous locations; d) Devices intended to be installed for manufacturing process control.

Preface This is the harmonized ANCE, CSA Group, and ULSE standard for Nonindustrial Photoelectric Switches for Lighting Contro l. It is the first edition of NMX-J-715-ANCE, the first edition of CSA-C22.2 No. 284-16, and the sixth edition of UL 773A. This edition of UL 773A supersedes the previous edition published on February 10, 2006. This harmonized standard has been jointly revised on January 16, 2024. For this purpose, CSA Group and ULSE are issuing revision pages dated January 16, 2024, and ANCE is issuing a new edition dated January 16, 2024. This harmonized standard was prepared by the Association of Standardization and Certification, (ANCE), CSA Group and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Subcommittee, on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. The CSA Group standard also replaces the following Technical Information Letters (T.I.L.), for products covered in this Standard: – TIL No. A-15 Photo-electric switches This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican standard was developed by the CT 23 Electrical Accesries from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the Electrical of manufactures, manufacturers and users. This standard was reviewed by the CSA Integrated Committee on Wiring Devices, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been developed in compliance with the Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 Requirements contained in this Standard cover controls of the light-sensitive or presence-sensitive types, or both; for indoor or outdoor service; intended for the control of indoor or outdoor loads up to a maximum of 20 A and maximum 347 V; intended for installations on 50 Hz or 60 HZ systems or DC up to 60 V (for US); and DC up to 42.4 V (for Canada); and intended to be installed in accordance with the National Electrical Code (NEC), NFPA 70, the Canadian Electrical Code (CE Code) Part I, CSA C22.2 No. 0, and NOM 001 SEDE. 1.2 These requirements do not cover controls intended to be used under the following conditions: a) Devices that are locking type, used for area or roadway lighting fixtures; b) Devices that monitor or control safety critical loads or personal protection circuits; c) Devices intended to be installed in areas designated hazardous locations; d) Devices intended to be installed for manufacturing process control.

DocumentType
Standard
ISBN
978-1-77139-138-2
Pages
0
ProductNote
THIS STANDARD ALSO REFERS TO :ANCE NMX-J–412, ANCE NMX-J-023/1,ANCE NMX-J-023/1,CSA 223,CSA 66.3,CSA 66.1,CSA 18.1,CSA 22.2 No. 42, CSA 22.2 No. 0.17,CSA 22.2 No. 0.2
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
US$292.32
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.