1 Scope
2 Normative references
3 Terms and definitions
4 Level of protection (equipment protection level, EPL)
5 Flameproof joints
6 Sealed joints
7 Operating rods
8 Supplementary requirements for shafts and bearings
9 Light-transmitting parts
10 Breathing and draining devices which form part of a
   flameproof enclosure
11 Fasteners and openings
12 Materials
13 Entries for flameproof enclosures
14 Verification and tests
15 Type tests
16 Routine tests
17 Switchgear for Group I
18 Lampholders and lamp caps
19 Non-metallic enclosures and non-metallic parts of
   enclosures
20 Marking
21 Instructions
Annex A (normative) - Additional requirements for crimped
        ribbon elements and multiple screen elements of
        breathing and draining devices
Annex B (normative) - Additional requirements for elements,
        with non-measurable paths of breathing and
        draining devices
Annex C (normative) - Additional requirements for flameproof
        entry devices
Annex D (normative) - Empty flameproof enclosures as
        Ex components
Annex E (normative) - Cells and batteries used in flameproof
        'd' enclosures
Annex F (informative) - Mechanical properties for screws
        and nuts
Annex G (normative) - Additional requirements for flameproof
        enclosures with an internal source of release
        (containment system)
Annex H (normative) - Requirements for machines with
        flameproof 'd' enclosures fed from converters
Bibliography

Includes specific requirements for the construction and testing of electrical equipment with the type of protection flameproof enclosure 'd', intended for use in explosive gas atmospheres.

DevelopmentNote
Supersedes CSA E60079.1. (05/2007)
DocumentType
Standard
Pages
223
PublisherName
Canadian Standards Association
Status
Superseded
Supersedes

C22.2 NO. 159-18 Plugs, connectors, receptacles, and similar wiring devices for use in hazardous locations
C22.1-15 PACKAGE Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference
CSA C22.2 No. 60079-15 : 2016 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
Z462-18 Workplace electrical safety
C22.1HB-18 Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I
CSA C22.2 No. 60079-26 : 2016 EXPLOSIVE ATMOSPHERES - PART 26: EQUIPMENT WITH EQUIPMENT PROTECTION LEVEL (EPL) GA
CSA C22.2 No. 60079-28 : 2016 EXPLOSIVE ATMOSPHERES - PART 28: PROTECTION OF EQUIPMENT AND TRANSMISSION SYSTEMS USING OPTICAL RADIATION
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
CSA CE CODE SAFETY PACKAGE : 2012 CE CODE SAFETY PACKAGE
C22.10-10 Québec Construction Code, Chapter V - Electricity Canadian Electrical Code, Part I (Twenty-first Edition) with Québec Amendments
C22.2 NO. 213-17 Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations (Binational standard with UL 121201)
UL 121201:9ED 2017-09 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
C22.1-18 Canadian Electrical Code, Part I (24th Edition), Safety Standard for Electrical Installations

CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
ISO 2738:1999 Sintered metal materials, excluding hardmetals — Permeable sintered metal materials — Determination of density, oil content and open porosity
IEC 61960:2011 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications
C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
CSA C22.2 No. 60079-15 : 2016 EXPLOSIVE ATMOSPHERES - PART 15: EQUIPMENT PROTECTION BY TYPE OF PROTECTION 'N'
CSA C22.2 No. 60079-11 : 2014 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
ISO 4003:1977 Permeable sintered metal materials — Determination of bubble test pore size
IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 61951-2:2017 Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride
ISO 4022:1987 Permeable sintered metal materials — Determination of fluid permeability
IEC 61951-1:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium
ISO 468:1982 Surface roughness — Parameters, their values and general rules for specifying requirements
UL 1203:5ED 2013-11 ExplosionProof and Dust-IgnitionProof Electrical Equipment for Use in Hazardous (Classified) Locations
ISO 80000-1:2009 Quantities and units — Part 1: General
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60086-1:2015 Primary batteries - Part 1: General
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
ISO 185:2005 Grey cast irons Classification
ISO 965-1:2013 ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data
ISO 965-3:1998 ISO general purpose metric screw threads Tolerances Part 3: Deviations for constructional screw threads
IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
IEC 60622:2002 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells

View more information
US$303.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.