DD ENV 28041:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Hardcopy , PDF
06-10-2005
English
09-15-1993
Cooperating organizations
National foreword
Foreword
Introduction to the European Prestandard
1. Scope
2. Normative references
3. Definitions
4. Characteristics
5. Frequency - weighting and amplifier characteristics
6. Detector and indicator characteristics
7. Sensitivity to various environments
8. Calibration and verification of the basic characteristics
of the vibration - measuring instrumentation
9. Rating information and instruction manual
Annexes
A (informative) Additional information
B (informative) Analytical expressions corresponding to
tables 4 to 8
C (informative) Graphs correponding to tables 4 to 8
D (informative) Time weighting
Tables
1 Frequency ranges
2 Preferred reference calibration frequencies
3 Maximum change in reading withing 1 h of operation
4 Frequency weighting : whole body, severe discomfort,
z axis, 0,1 Hz to 1 Hz (motion sickness) based on ISO 2631-3
5 Frequency weighting : whole body, x axis and y axis, 1 Hz to
80 Hz, based on ISO 2631
6 Frequency weighting : whole body, z axis, 1 Hz to 80 Hz,
based on ISO 2631
7 Frequency weighting : whole body, combined, 1 Hz to 80 Hz,
based on ISO 2631
8 Frequency weighting : hand-arm, based on ISO 5349
9 Maximum error for r.m.s. detector - indicator system
10 Response to test signal bursts
11 Tolerances for linear integration
12 Tolerances on sensitivity linearity referred to the reference
Figures
1 Rectangular - pulse set
C.1 Frequency weighting (magnitude) for whole body, severe
discomfort, z axis, 0,1 Hz to 0,63 Hz (motion sickness) :
corresponds to table 4
C.2 Frequency weighting (magnitude) for whole body, x axis and
y axis, 1 Hz to 80 Hz: corresponds to table 5
C.3 Frequency weighting (magnitude) for whole body, z axis, 1 Hz
to 80 Hz: corresponds to table 6
C.4 Frequency weighting (magnitude) for whole body, combined,
1 Hz to 80 Hz: corresponds to table 7
C.5 Frequency weighting (magnitude) for hand/arm, 8 Hz to 1 000 Hz:
corresponds to table 8
D.1 Weighting curves for linear and exponential integration
National Annexes
National annex NA (informative) Committees responsible
National annex NB (informative) Cross references
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.