• There are no items in your cart

DEFSTAN 00-101(PT3)/2(2008) : 2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION

Available format(s)

Hardcopy , PDF

Superseded date

11-28-2020

Language(s)

English

Published date

01-01-2008

0. INTRODUCTION
1. SCOPE
2. WARNING
3. RELATED DOCUMENTS
4. DEFINITIONS AND ABBREVIATIONS
5. AMENDMENT
6. SPONSORSHIP OF THE REQUIREMENT AND SECURITY
7. STATUTORY LEGISLATION AND MOD REGULATION FOR PLATFORM
   EXPLOSIVE SAFETY
8. INTRODUCTION TO PLATFORM EXPLOSIVES SAFETY AND CERTIFICATION
9. DESIGN FOR PLATFORM EXPLOSIVES SAFETY INCORPORATING
   THREAT HAZARD ASSESSMENT & LINES OF DEFENCE
APPENDIX 1 - DESIGN REQUIREMENTS FOR ELECTRICAL EQUIPMENT
             IN MAGAZINES, WSCs AND DESIGNATED DANGER AREAS
   1.1 Description
   1.2 Performance Requirements - Categorisation of Magazines
   1.3 Performance Requirements - Basic Principles for
        Magazine Electrical Equipment
   1.4 Performance Requirements - Basic Principles - Zone 2
        Magazines
   1.5 ACOP - Basic Principles - Zone 2 Magazines
   1.6 ACOP - Zone 2 Magazine Electrical Equipment Categories
   1.7 Performance Requirement - Assessment of Equipment for
        use in Zone 2
   1.8 ACOP - Electrical Equipment Enclosures
   1.9 ACOP - The Radio Frequency (rf) Environment
   1.10 ACOP - Magnetic Environment and Degaussing Cables
   1.11 Guidance - Basic Principles for Magazine, WSC & DDA
        Electrical Equipment
   1.12 Guidance - Basic Principles for Zone 2 Magazine,
        WSC & DDA Electrical Equipment
   1.13 Guidance on Maximum Surface Temperature
   1.14 Guidance on Electrical Equipment Enclosures
   1.15 Guidance on Intrinsically Safe Equipment
   1.16 Guidance on Mobile Mechanical Handling Equipment (MMHE)
   1.17 Guidance on Mechanical Hazards
   1.18 Guidance on Safety and Environmental Management Systems
        (SEMS)
APPENDIX 2 - DESIGN REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
   2.1 Description
   2.2 Performance Requirements for General Installation
        and Siting
   2.3 Performance Requirements for Cabling
   2.4 Performance Requirements for Circuit Isolation
   2.5 Performance Requirements for Emergency Supplies
   2.6 Performance Requirements for Fixed Lighting
   2.7 Performance Requirements for Power Output Connectors
   2.8 Performance Requirements for Installed Test Equipment
   2.9 Performance Requirements for Electrically Controlled
        Handling Machinery
   2.10 Performance Requirements for Safety-Related Devices
   2.11 Performance Requirements for Earthing
   2.12 ACOP for Siting of Equipment
   2.13 ACOP for Cabling
   2.14 ACOP for Circuit Isolation
   2.15 ACOP for Emergency Supplies
   2.16 ACOP for Luminaries (Fixed Lighting)
   2.17 ACOP for Power Output Connectors
   2.18 ACOP for Test Equipment
   2.19 ACOP for Electrically Controlled Handling Machinery
   2.20 ACOP for Safety-Related Devices
   2.21 ACOP for Earthing
   2.22 Guidance on General Electrical Installation
   2.23 Guidance on Siting of Equipment
   2.24 Guidance on Cabling
   2.25 Guidance on Circuit Isolation
   2.26 Guidance on Fixed Lighting
   2.27 Guidance on Power Output Connectors
   2.28 Guidance on Test Equipment
   2.29 Guidance on Electrically Controlled Handling Machinery
APPENDIX 3 - DESIGN REQUIREMENTS FOR ADJACENT COMPARTMENTS
   3.1 Description
   3.2 Performance Requirements for Electrical Design in
        Adjacent Compartments
   3.3 Performance Requirements for Electrical Equipment
        in Adjacent Compartments
   3.4 Performance Requirements for Electrical Installation
        in Adjacent Compartments
   3.5 Performance Requirements for Smoke/Heat Detection
        Equipment in Adjacent Compartments
   3.6 ACOP for Special Requirements in Adjacent Compartments
   3.7 ACOP for Special Requirements for Installation in
        Adjacent Compartments
   3.8 ACOP for Smoke and Heat Detection Equipment
   3.9 Guidance on Electrical Equipment in Adjacent Compartments
APPENDIX 4 - DESIGN REQUIREMENTS FOR TEMPORARILY INSTALLED EQUIPMENT
   4.1 Description
   4.2 Performance Requirements for Portable Equipment
   4.3 Performance Requirements for Emergency Lighting
   4.4 ACOP for Temporarily Installed Equipment
   4.5 Guidance on Temporarily Installed Equipment
   4.6 Guidance on Compliance for Portable Equipment
APPENDIX 5 - ELECTROMAGNETIC INDUCTION, RADIO FREQUENCY AND
             ELECTROSTATIC HAZARDS
   5.1 Description
   5.2 Performance Requirements for Design to Reduce
        Electromagnetic Induction, Radio Frequency and
        Electrostatic Hazards
   5.3 ACOP for Electromagnetic Induction, Radiation and
        Electrostatic Hazards
   5.4 Guidance on Electromagnetic Induction, Radiation and
        Electrostatic Hazards
APPENDIX 6 - POTENTIALLY HAZARDOUS ENVIRONMENTS OF A SPECIAL
             NATURE
   6.1 Description
   6.2 Performance Requirements for Potentially Hazardous
        Environments of a Special Nature
   6.3 Performance Requirements for Degaussing Cables
   6.4 Performance Requirements for Waveguides
   6.5 Performance Requirements for Cranes
   6.6 Performance Requirements for Ship to Shore Electrical
        Connections
   6.7 ACOP for Waveguides
   6.8 ACOP for Cranes
   6.9 ACOP for Ship to Shore Electrical Connections
   6.10 ACOP for Earthing of Weapon Containers
   6.11 Guidance on Degaussing Cables
   6.12 Guidance on Waveguides
   6.13 Guidance on Ship to Shore Connections
APPENDIX 7 - Electrical Requirements for ISO Containers
   7.1 Description
   7.2 ACOP for Earthing of ISO Containers
   7.3 Guidance on Earthing of ISO Containers
ANNEX A - RELATED DOCUMENTS
ANNEX B - ABBREVIATIONS
ANNEX C - DEFINITIONS

Applies to the design, construction and ship fitting of all MOD Ships built to MOD or Classification Society constructional standards and operated by the Royal Navy, Army, Royal Air Force, RFA or Marine Services.

DevelopmentNote
Supersedes DEFSTAN 00-101(PT3)/1(2005). (08/2008) This standard is obsolescent because it is no longer required for procurement of new equipment but is retained for maintenance purposes in support of existing in-service equipment. (09/2017)
DocumentType
Standard
Pages
71
PublisherName
UK Ministry of Defence Standards
Status
Superseded
SupersededBy
Supersedes

DEFSTAN 08-107/3(2013) : 2013 GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROTECHNICAL AND NAVAL WEAPON EQUIPMENT

DEFSTAN 02-603/2(2001) : INTERIM REQUIREMENTS FOR THE POLICY, DESIGN AND INSTALLATION OF FIRE DETECTION SYSTEMS IN SHIPS
IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-10:2002 Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
DEFSTAN 02-529(PT2)/1(2000) : 2000 NUCLEAR HARDENING GUIDE - PART 2: ELECTRICAL INSTALLATION IN SURFACE SHIPS
AOP 39 : 2010 GUIDANCE ON THE ASSESSMENT AND DEVELOPMENT OF INSENSITIVE MUNITIONS (IM)
NES 532 : ISSUE 2 GUIDE TO THE DESIGN OF ELECTRICAL SUPPLY AND DISTRIBUTION SYSTEMS IN SURFACE SHIPS
DEFSTAN 08-108(PT1)/1(2000) : 2000 NUCLEAR HARDENING GUIDE - CATEGORY 1 - PART 1: HARDENING AGAINST NUCLEAR EMP AND INR
DEFSTAN 59-411(PT5)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 5: CODE OF PRACTICE FOR TRI-SERVICE DESIGN AND INSTALLATION
DEFSTAN 02-113/1(2005) : 2005 REQUIREMENT FOR MECHANICAL HANDLING
BS EN 50021:1999 Electrical apparatus for potentially explosive atmospheres. Type of prot ection \'n\'
BS EN 61386-1:2008 Conduit systems for cable management General requirements
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
DEFSTAN 08-123/1(2000) : 2000 REQUIREMENTS FOR THE DESIGN AND TESTING OF EQUIPMENTS TO MEET ENVIRONMENTAL CONDITIONS - CATEGORY 2
BS EN 50014:1998 Electrical apparatus for potentially explosive atmospheres. General requirements
DEFSTAN 08-160/1(2003) : 2003 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - CATEGORY 2
DEFSTAN 02-602/1(2000) : 2000 GUIDE TO THE INSTALLATION OF THORN SECURITY AUTOMATIC FIRE DETECTION SYSTEMS CATEGORY N/A
BS EN 50016:2002 Electrical apparatus for potentially explosive atmospheres. Pressurized apparatus \'p\'
DEFSTAN 08-109/2(2001) : 2001 REQUIREMENTS FOR THE DESIGN OF ELECTRICAL SUPPLY AND DISTRIBUTION SYSTEMS IN SURFACE SHIPS AND SUBMARINES - CATEGORY 1
NES 1004 : ISSUE 2 AMD 1 REQUIREMENTS FOR DESIGN AND TESTING OF EQUIPMENTS TO MEET ENVIRONMENTAL CONDITIONS
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
DEFSTAN 59-411(PT4)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 4: PLATFORM AND SYSTEM TEST AND TRIALS
NES 529 PT1 : ISSUE 2 NUCLEAR HARDENING GUIDE - HARDENING AGAINST NUCLEAR EMP AND INR (RESTRICTED)
DEFSTAN 08-4(PT1)/2(1992) : 1992 NUCLEAR WEAPONS EXPLOSIONS EFFECTS AND HARDENING - PART 1: NUCLEAR WEAPONS EXPLOSIONS: RESULTING ENVIRONMENTS
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
DEFSTAN 08-107/2(2001) : 2001 GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROMECHANICAL AND NAVAL WEAPON EQUIPMENT - CATEGORY 2
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-3:1990 Electrical apparatus for explosive gas atmospheres - Part 3: Spark-test apparatus for intrinsically-safe circuits
BS EN 50017:1998 Electrical apparatus for potentially explosive atmospheres. Powder filling \'q\'
DEFSTAN 08-4(PT3)/2(1992) : 1992 NUCLEAR WEAPONS EXPLOSIONS EFFECTS AND HARDENING - PART 3: NUCLEAR WEAPONS EXPLOSIONS: SIMULATION OF ENVIRONMENTS
BS EN 50019:2000 Electrical apparatus for potentially explosive atmospheres. Increased safety \'e\'
PD 60079-14:2000 Guide to application of BS EN 60079-14
DEFSTAN 02-607/2(2008) : 2008 DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
DEFSTAN 59-411(PT3)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 3: TEST METHODS AND LIMITS FOR EQUIPMENT AND SUB SYSTEMS
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
DEFSTAN 08-124/1(2000) : 2000 RADIO FREQUENCY ENVIRONMENT AND ACCEPTANCE CRITERIA FOR NAVAL STORES CONTAINING ELECTRO-EXPLOSIVE DEVICES - CATEGORY 1
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
NES 529 PT2 : ISSUE 1 NUCLEAR HARDENING GUIDE - ELECTRICAL INSTALLATION IN SURFACE SHIPS
DEFSTAN 08-147(PT2)/1(2000) : 2000 REQUIREMENTS FOR DAMAGE CONTROL AND FIRE PROTECTION FOR THE SAFETY OF SURFACE SHIPS AND SUBMARINES - CATEGORY 1 - PART 2: SUBMARINES
DEFSTAN 08-4(PT2)/2(1992) : 1992 NUCLEAR WEAPONS EXPLOSIONS EFFECTS AND HARDENING - PART 2: NUCLEAR WEAPONS EXPLOSIONS: EFFECTS ON MATERIEL
BS EN 50015:1998 Electrical apparatus for potentially explosive atmospheres. Oil immersion \'o\'
STANAG 4439 : 2010 POLICY FOR INTRODUCTION AND ASSESSMENT OF INSENSITIVE MUNITIONS (IM)
DEFSTAN 59-411(PT2)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 2: THE ELECTRIC, MAGNETIC AND ELECTROMAGNETIC ENVIRONMENT
NES 501 : RESTRICTED GENERAL REQUIREMENTS FOR THE DESIGN OF ELECTROTECHNICAL AND NAVAL WEAPON EQUIPMENT
NES 602 : ISSUE 2 GUIDE TO THE INSTALLATION OF THORN SECURITY AUTOMATIC FIRE DETECTION SYSTEMS
BS 4568-1:1970 Specification for steel conduit and fittings with metric threads of ISO form for electrical installations Steel conduit, bends and couplers
DEFSTAN 59-411(PT1)/1(2007) : 2007 ELECTROMAGNETIC COMPATIBILITY - PART 1: MANAGEMENT AND PLANNING
NES 1006 : ISSUE 3 RADIO FREQUENCY ENVIRONMENT AND ACCEPTANCE CRITERIA FOR NAVAL STORES CONTAINING ELECTRO-EXPLOSIVE DEVICES
DEFSTAN 08-4(PT4)/2(191993) : 1993 NUCLEAR WEAPONS EXPLOSIONS EFFECTS AND HARDENING - PART 4: NUCLEAR WEAPONS EXPLOSIONS: HARDENING AND TESTING
BS EN 50020:2002 Electrical apparatus for potentially explosive atmospheres. Intrinsic safety \'i\'
BS EN 50018:2000 Electrical apparatus for potentially explosive atmospheres. Flameproof enclosure \'d\'

View more information
US$71.87
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.