    GLASS IN BUILDING - DETERMINATION OF THE BENDING STRENGTH OF GLASS - PART 1: FUNDAMENTALS OF TESTING GLASS

    Available format(s):  Hardcopy, PDF

    Language(s):  German, English

    Published date:  01-01-2000

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add to Watchlist

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Vorwort
    1 Anwendungsbereich
    2 Normative Verweisungen
    3 Definitionen
    4 Formelzeichen
    5 Grundlagen der Festigkeitsprüfung von Glas
       5.1 Glas als Werkstoff
       5.2 Biegespannung und Biegefestigkeit
       5.3 Glasarten
       5.4 Orientierung der Proben
       5.5 Anzahl der Proben in einer Stichprobe
    6 Erklärung der Prüfverfahren
       6.1 Doppelring-Biegeversuch mit grossen Prüfflächen
       6.2 Prüfung von Proben bei zweiseitiger Auflagerung
            (Vierschneiden-Biegung)
       6.3 Doppelring-Biegeversuch mit kleinen Prüfflächen
    7 Anwendungsbereiche der Prüfverfahren
       7.1 Allgemeine Grenzen
       7.2 Grenzen von EN 1288-2
       7.3 Grenzen von EN 1288-3
       7.4 Grenzen von EN 1288-4
       7.5 Grenzen von EN 1288-5
    8 Kalibrierung der Prüfmaschinen
    9 Sicherheitstechnische Anforderungen
    Anhang A (informativ) Literaturhinweise

    Abstract - (Show below) - (Hide below)

    Defines the determination of the bending strength of monolithic glass for use in buildings. Insulating units or laminated glass testing is excluded from this standard. This standard describes: explanations of the reasons for designing different test methods; limitations to the test methods; consideration to be taken into account when testing glass, and gives pointers to safety requirement for the personnel operating the test equipment. Test methods in this standard are intended to provide large numbers of bending strength values that can be used as the basis for statistical evaluation of glass strength. Test methods are specified in detail in EN 1288-2, EN 1288-3, EN 1288-4, AND EN 1288-5.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN 52300-1, DIN 52292-1 and -2 (09/2000)
    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 572-3:2012 Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass
    EN 12337-1:2000 Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description
    EN 13024-1:2011 Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description
    EN 572-7:2012 Glass in building - Basic soda lime silicate glass products - Part 7: Wired or unwired channel shaped glass
    EN 1863-1:2011 Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description
    EN 1748-2 : 1997 GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - GLASS CERAMICS
    EN 572-6:2012 Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass
    EN 1288-3:2000 Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending)
    EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
    EN 1288-5:2000 Glass in building - Determination of the bending strength of glass - Part 5: Coaxial double ring test on flat specimens with small test surface areas
    EN 12150-1:2015 Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
    EN 1288-4:2000 Glass in building - Determination of the bending strength of glass - Part 4: Testing of channel shaped glass
    EN 572-4:2012 Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass
    EN 1748-1 : 1997 GLASS IN BUILDING - SPECIAL BASIC PRODUCTS - BOROSILICATE GLASSES
    EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
    EN 572-5:2012 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass
    EN 1288-2:2000 Glass in building - Determination of bending strength of glass - Part 2: Coaxial double ring test on flat specimens with large test surface areas
    EN ISO 12543-1:2011 Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective