DIN EN 13463-1:2009-07

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

NON-ELECTRICAL EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES - PART 1: BASIC METHOD AND REQUIREMENTS
Available format(s)

Hardcopy , PDF

Superseded date

12-01-2016

Language(s)

English

Published date

01-01-2009

Vorwort
Einleitung
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Gerätekategorien und Explosionsgruppen
  4.1 Gerätekategorie
  4.2 Explosionsgruppen (Unterteilungen)
  4.3 Spezifische explosionsfähige
       Atmosphären
5 Zündgefahrenbewertung
  5.1 Allgemeine Anforderungen
  5.2 Ablauf der Zündgefahrenbewertung
6 Bewertung von möglichen Zündquellen
  6.1 Allgemeines
  6.2 Heisse Oberflächen
  6.3 Flammen und heisse Gase (einschliesslich
       heisse Partikel)
  6.4 Mechanisch erzeugte Funken
  6.5 Elektrische Zündquellen
  6.6 Elektrische Streuströme, kathodischer
       Korrosionsschutz
  6.7 Statische Elektrizität
  6.8 Blitzschlag
  6.9 Elektromagnetische Hochfrequenzwellen (RF)
       von 10[4] Hz bis 3 x 10[12] Hz
  6.10 Elektromagnetische Wellen von 3 x 10[11]
       Hz bis 3 x 10[15] Hz
  6.11 Ionisierende Strahlung
  6.12 Ultraschall
  6.13 Adiabatische Kompression und Druckwellen
  6.14 Exotherme Reaktionen, einschliesslich
       Selbstentzündung von Stäuben
7 Zusätzliche Betrachtungen
  7.1 Staubablagerungen und anderes Material in
       den Spalten sich bewegender Teile
  7.2 Zeit zum Öffnen von Gehäusen
  7.3 Nichtmetallische Teile der Geräte
  7.4 Abnehmbare Teile
  7.5 Zum Verkleben verwendete Materialien
  7.6 Lichtdurchlässige Teile
8 Verifizierung und Prüfungen
  8.1 Allgemeines
  8.2 Bestimmung der maximalen Oberflächentemperatur
  8.3 Entflammbarkeitsprüfung
  8.4 Mechanische Prüfungen
  8.5 Zusätzliche Prüfungen von nichtmetallischen
       Geräteteilen, die für den Explosionsschutz
       von Bedeutung sind
9 Dokumentation und Bedienungsanleitung
  9.1 Technische Dokumentation des Herstellers
  9.2 Bedienungsanleitung
  9.3 Kennzeichnung
  9.4 Beispiele für die vollständige Kennzeichnung
       (informativ)
Anhang A (normativ) Verfahrensweise bei der Festlegung
          der Kategorie
Anhang B (informativ) Erläuterung des Verfahrens der
          Zündgefahrenbewertung
Anhang C (informativ) Beispiele der Zündgefahrenbewertung
Anhang D (informativ) Aufladungsprüfungenvon nicht
          leitenden Materialien
Anhang E (informativ) Beispiel einer Prüfeinrichtung für
          die Schlagfestigkeitsprüfung
Anhang F (normativ) Prüfeinrichtung für die
          Schlagzündprüfung
Anhang G (informativ) Vernünftigerweise vorhersehbarer
          Fehlgebrauch der bei der Zündgefahrenbewertung
          zu berücksichtigen ist
Anhang H (informativ) Massgebliche Änderungen
          zwischen dieser Europäischen Norm und der
          vorherigen Ausgabe
Anhang ZA (informativ) Zusammenhang zwischen dieser
          Europäischen Norm und den grundlegenden
          Anforderungen der EG-Richtlinie 94/9/EG
Literaturhinweise
Bilder
Tabellen

This standard is included in DIN HDBK 412.

DevelopmentNote
A transition period, as set out in DIN EN ISO 80079-36 issue 12-2016, exists until 31-10-2019. (04/2017)
DocumentType
Standard
Pages
75
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

Standards Relationship
EN 13463-1:2009 Identical
SN EN 13463-1 : 2009 Identical
UNI EN 13463-1 : 2009 Identical
NEN EN 13463-1 : 2009 Identical
NF EN 13463-1 : 2009 Identical
NS EN 13463-1 : 2009 Identical
I.S. EN 13463-1:2009 Identical
NBN EN 13463-1 : 2009 Identical
BS EN 13463-1:2009 Identical
UNE-EN 13463-1:2011 Identical

VDI 2263 Blatt 5:2014-10 Dust fires and dust explosions - Hazards, assessment, protective measures - Explosion protection in fluidized bed dryers
VDI 2263 Blatt 8:2008-12 Dust fires and dust explosions - Hazards - Assessment - Protective measures - Fire and explosion protection on elevators
VDI/VDE 3844:2014-01 Industrial process control valves - Actuators for control valves
VDI 2263 Blatt 8.1:2011-03 Dust fires and dust explosions - Hazards - assessment - protective measures - Fire and explosion protection on elevators - Examples
VDI 2262 Blatt 1:2013-06 Workplace air - Reduction of exposure to air pollutants - Legal principles, terms and definitions, basic organisational measures for industrial safety and environmental protection
VDI 2263 Blatt 6:2017-08 Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations
VDI 3476 Blatt 2:2010-01 Waste gas cleaning - Catalytic waste gas cleaning methods - Oxidative processes
VDE 0170-12-2 : 2001-05 GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST
DIN EN 50303 : 2001-05 GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST
DIN HDBK 412 : 1ED 2015

EN 62262:2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
ISO 6507-1:2005 Metallic materials Vickers hardness test Part 1: Test method
EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
EN 60079-26:2015 Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
ISO 6507-4:2005 Metallic materials Vickers hardness test Part 4: Tables of hardness values
EN 582:1993 Thermal spraying - Determination of tensile adhesive strength
EN 60079-1:2014 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN 12874 : 2001 FLAME ARRESTERS - PERFORMANCE REQUIREMENTS, TEST METHODS AND LIMITS FOR USE
EN 13237:2012 Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres
EN 13463-6:2005 Non-electrical equipment for use in potentially explosive atmospheres - Part 6: Protection by control of ignition source 'b'
EN 60079-28:2015 Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
ISO 281:2007 Rolling bearings Dynamic load ratings and rating life
EN 14986:2017 Design of fans working in potentially explosive atmospheres
EN 1755:2015 Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres
EN 13463-8:2003 Non-electrical equipment for potentially explosive atmospheres - Part 8: Protection by liquid immersion 'k'
EN 61241-1:2004/corrigendum Dec. 2006 ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1: PROTECTION BY ENCLOSURES "TD"
EN 1127-2:2014 Explosive atmospheres - Explosion prevention and protection - Part 2: Basic concepts and methodology for mining
EN ISO 12100-1:2003/A1:2009 SAFETY OF MACHINERY - BASIC CONCEPTS, GENERAL PRINCIPLES FOR DESIGN - PART 1: BASIC TERMINOLOGY, METHODOLOGY
EN 15198:2007 Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres
IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
EN 13463-2:2004 Non-electrical equipment for use in potentially explosive atmospheres - Part 2: Protection by flow restricting enclosure 'fr'
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
ISO 12100-1:2003 Safety of machinery Basic concepts, general principles for design Part 1: Basic terminology, methodology
EN 14522:2005 Determination of the auto ignition temperature of gases and vapours
EN 13463-5:2011 Non-electrical equipment intended for use in potentially explosive atmospheres - Part 5: Protection by constructional safety 'c'
EN 13463-3:2005 Non-electrical equipment for use in potentially explosive atmospheres - Part 3: Protection by flameproof enclosure 'd'
IEC TR 60079-12:1978 Electrical apparatus for explosive gas atmospheres - Part 12:Classification of mixtures of gases of vapours with air accordingto their maximum experimental safe gaps and minimum ignitingcurrents
EN 50303:2000 Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
CLC/TR 50404:2003 Electrostatics - Code of practice for the avoidance of hazards due to static electricity
ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids
1994/9/EC : 1994 DIRECTIVE 94/9/EC OF THE EUROPEAN PARLIAMENT AND THE COUNCIL OF 23 MARCH 1994 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES CONCERNING EQUIPMENT AND PROTECTIVE SYSTEMS INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES
EN 60079-2:2014/AC:2015 EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014)

View more information

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.