• There are no items in your cart

DIN EN 13786:2010-07

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

AUTOMATIC CHANGE-OVER VALVES HAVING A MAXIMUM OUTLET PRESSURE OF UP TO AND INCLUDING 4 BAR WITH A CAPACITY OF UP TO AND INCLUDING 100 KG/H, AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
Available format(s)

Hardcopy , PDF

Superseded date

08-01-2013

Language(s)

English

Published date

01-01-2010

Foreword
1 Scope
2 Normative references
3 Terms and definitions
  3.1 General terms and definitions
  3.2 Terms and definitions concerning gas
  3.3 Terms and definitions concerning pressures
  3.4 Terms and definitions concerning rates
4 Types of automatic change over devices
  4.1 Introduction
  4.2 Automatic change over devices for installations where the
      final regulator supplies a pressure specified in EN 437
  4.3 Other automatic change over devices installation
5 Constructional characteristics
  5.1 General
  5.2 Materials
  5.3 Special requirements
      5.3.1 Pressure sensing subassembly
      5.3.2 Regulation subassembly
      5.3.3 Back pressure subassembly
      5.3.4 Connection subassembly
      5.3.5 Supply-reserve indicator
      5.3.6 Knob for selection of the operational cylinder
      5.3.7 Fixing onto a wall
  5.4 Mechanical strength
      5.4.1 Resistance to pressure
      5.4.2 Strength of connections
  5.5 Soundness
  5.6 Mechanical endurance
  5.7 Resistance to humidity changes
  5.8 Resistance to corrosion
6 Performance characteristics
  6.1 General
      6.1.1 Introduction
      6.1.2 Supply pressure
  6.2 Operational limit characteristics (regulation
      function)
  6.3 Operational limit characteristics (Change over
      function)
      6.3.1 Gas flow safety
      6.3.2 Change over pressure
      6.3.3 Selection of the operating cylinder
7 Test methods
  7.1 General conditions
      7.1.1 Type of test gas
      7.1.2 Test conditions
      7.1.3 Equivalence formulae
      7.1.4 Test samples
  7.2 Verification of constructional characteristics
      7.2.1 Resistance to pressure
      7.2.2 Mechanical strength of connections
      7.2.3 Regulation subassembly
      7.2.4 Soundness
      7.2.5 Endurance
      7.2.6 Resistance to humidity changes
      7.2.7 Resistance to corrosion
  7.3 Verification of performance characteristics
      7.3.1 General
      7.3.2 Plotting of regulation curves
8 Marking, packaging, instructions
  8.1 General
  8.2 Marking of the device
  8.3 Packaging
  8.4 Instructions for use and maintenance
Annex A (normative) Special requirements for automatic change
                    over devices fitted with pressure or rate
                    operated safety valves
  A.1 Change over devices fitted with an over-pressure relief
      A.1.1 Definition
      A.1.2 Constructional characteristics
      A.1.3 Performance characteristics
            A.1.3.1 Automatic change over devices having a
                    maximum regulated pressure of up to and
                    including 150 mbar
            A.1.3.2 Automatic change over devices having a
                    maximum regulated pressure exceeding 150
                    mbar
      A.1.4 Test methods
            A.1.4.1 Automatic change over devices having a
                    maximum regulated pressure of up to and
                    including 150 mbar
            A.1.4.2 Automatic change over devices having a
                    maximum regulated pressure exceeding 150 mbar
      A.1.5 Automatic change over device marking
  A.2 Automatic change over device fitted with an over-pressure
      shut off safety valve
      A.2.1 Definition
      A.2.2 Constructional characteristics
            A.2.2.1 General
            A.2.2.2 Closing force
            A.2.2.3 Diaphragm strength
      A.2.3 Performance characteristics
            A.2.3.1 Automatic change over devices with a
                    maximum regulated pressure of up to and
                    including 150 mbar
            A.2.3.2 Automatic change over devices with a
                    maximum regulated exceeding 150 mbar
      A.2.4 Test methods
            A.2.4.1 Test for the components transmitting the
                    closing forces
            A.2.4.2 Test for diaphragm strength
            A.2.4.3 Performance test
  A.3 Automatic change over device fitted with an under-pressure
      shut off safety device
      A.3.1 Definition
      A.3.2 Constructional and performance characteristics
      A.3.3 Test methods
  A.4 Automatic change over devices fitted with an excess flow
      valve
      A.4.1 Definition
      A.4.2 Performance characteristics
      A.4.3 Complementary tests for the automatic change over
            devices - Test methods
      A.4.4 User and maintenance instructions
  A.5 Automatic change over devices fitted with a regulated
      pressure limiter
      A.5.1 Definition
      A.5.2 Constructional and performance characteristics
      A.5.3 Test methods
            A.5.3.1 Test conditions
            A.5.3.2 Measurement of the maximum regulated
                    pressure
            A.5.3.3 Measurement of the pressure drop
      A.5.4 Users and maintenance instructions
Annex B (normative) Special requirements for automatic change
                    over devices and automatic change over
                    devices systems for caravans and leisure
                    vehicles
Annex C (normative) Special requirements for low pressure
                    automatic change over devices under extreme
                    temperature conditions (temperatures below -
                    20 degree C)
Annex D (normative) Method for measuring leaks at test pressures
                    less than or equal to 16 bar
  D.1 Scope
  D.2 Diagram of the test
  D.3 Coefficient K
      D.3.1 Method
      D.3.2 Calculations
  D.4 Measurement of the leak
      D.4.1 Method
      D.4.2 Calculations
  D.5 Checks
Annex E (normative) Complementary test requirements for non
                    metallic thermoplastic or thermal setting
                    materials used in the construction of
                    automatic change over devices
  E.1 Scope
  E.2 Materials
  E.3 Special conditions for carrying out the test mentioned in
      the body of the standard
      E.3.1 Resistance to impact
      E.3.2 Mechanical resistance of connections
      E.3.3 Soundness
  E.4 Special requirements
      E.4.1 Resistance to hydrocarbons
      E.4.2 Resistance to cracking under stress and when chemical
            agents are present
      E.4.3 Characteristics relating to fire resistance
      E.4.4 Accelerated ageing
  E.5 Sampling and order of tests
Annex F (normative) Requirements for elastomeric reinforced
                    diaphgrams
Annex G (normative) Inlet connections
Annex H (normative) Outlet connections
Annex I (normative) Test method for resistance to corrosion
  I.1 Principle
  I.2 Reagents
      I.2.1 Saline solution
      I.2.2 Compressed air
      I.2.3 Salt mist
  I.3 Apparatus
      I.3.1 Spraying chamber
      I.3.2 Sprayers
      I.3.3 Heating device
      I.3.4 Salt solution supply device
      I.3.5 Compressed air supply device
      I.3.6 Mist collectors
  I.4 Test method
      I.4.1 Method of exposure of automatic change over device
      I.4.2 Duration of tests
      I.4.3 Checks
      I.4.4 Cleaning of automatic change over device
  I.5 Results
Annex ZA (informative) Clauses of this European Standard addressing
                       essential requirements or other provisions of
                       EU Directives
Bibliography

Describes the constructional and operational characteristics, the safety requirements and test methods, and the marking of automatic change over devices with a capacity of less than or equal to 100 kg/h and having a maximum regulated pressure of less than or equal to 4 bar for butane, propane or their mixtures only in the vapour phase.

DocumentType
Standard
Pages
147
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

VDI 6020 Blatt 1:2001-05 Requirements on methods of calculation to thermal and energy simulation of buildings and plants - Buildings

EN 12864:2001/A3:2009 LOW-PRESSURE, NON ADJUSTABLE REGULATORS HAVING A MAXIMUM OUTLET PRESSURE OF LESS THAN OR EQUAL TO 200 MBAR, WITH A CAPACITY OF LESS THAN OR EQUAL TO 4 KG/H, AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
ISO 7005-2:1988 Metallic flanges — Part 2: Cast iron flanges
EN ISO 75-3:2004/AC:2006 Plastics - Determination of temperature of deflection under load - Part 3: High-strength thermosetting laminates and long-fibre-reinforced plastics (ISO 75-3:2004)
EN ISO 180:2000/A2:2013 PLASTICS - DETERMINATION OF IZOD IMPACT STRENGTH (ISO 180:2000/AMD 2:2013)
EN ISO 527-4:1997 PLASTICS - DETERMINATION OF TENSILE PROPERTIES - PART 4: TEST CONDITIONS FOR ISOTROPIC AND ORTHOTROPIC FIBRE-REINFORCED PLASTIC COMPOSITES
EN ISO 4892-3:2016 Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3:2016)
EN ISO 9773:1998/A1:2003 Plastics - Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source - Amendment 1: Specimens (ISO 9773:1998/Amd 1:2003)
ISO 9773:1998 Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source
ISO 565:1990 Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings
EN ISO 178:2010/A1:2013 PLASTICS - DETERMINATION OF FLEXURAL PROPERTIES (ISO 178:2010/AMD 1:2013)
EN ISO 7253 : 2001 PAINTS AND VARNISHES - DETERMINATION OF RESISTANCE TO NEUTRAL SALT SPRAY (FOG)
EN ISO 3166-1:2014 Codes for the representation of names of countries and their subdivisions - Part 1: Country codes (ISO 3166-1:2013)
DIN ISO 565:1998-12 TEST SIEVES - METAL WIRE CLOTH, PERFORATED METAL PLATE AND ELECTROFORMED SHEET - NOMINAL SIZES OF OPENINGS
DIN EN 1774:1997-11 ZINC AND ZINC ALLOYS - ALLOYS FOR FOUNDRY PURPOSES - INGOT AND LIQUID
EN ISO 228-1:2003 Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000)
ISO 7-1:1994 Pipe threads where pressure-tight joints are made on the threads Part 1: Dimensions, tolerances and designation
EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
ISO 180:2000 Plastics Determination of Izod impact strength
ISO 4892-3:2016 Plastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps
EN 1949:2011+A1:2013 Specification for the installation of LPG systems for habitation purposes in leisure accommodation vehicles and accommodation purposes in other vehicles
EN 12164:2016 Copper and copper alloys - Rod for free machining purposes
EN 13785:2005+A1:2008 Regulators with a capacity of up to and including 100 kg/h, having a maximum nominal outlet pressure of up to and including 4 bar, other than those covered by EN 12864 and their associated safety devices for butane, propane or their mixtures
ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests
ISO 3166-1:2013 Codes for the representation of names of countries and their subdivisions Part 1: Country codes
EN 549:1994 Rubber materials for seals and diaphragms for gas appliances and gas equipment
EN 12165:2016 COPPER AND COPPER ALLOYS - WROUGHT AND UNWROUGHT FORGING STOCK
ISO 301:2006 Zinc alloy ingots intended for castings
ISO 178:2010 Plastics Determination of flexural properties
ISO 228-1:2000 Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation

View more information
US$237.07
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.