RESPIRATORY PROTECTIVE DEVICES - SELF-CONTAINED OPEN-CIRCUIT COMPRESSED AIR BREATHING APPARATUS WITH HALF MASK DESIGNED TO BE USED WITH POSITIVE PRESSURE ONLY - REQUIREMENTS, TESTING, MARKING

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2004

Foreword
Introduction
1 Scope
2 Normative References
3 Terms and definitions
4 Description
5 Requirements
   5.1 General
   5.2 Ergonomics
   5.3 Design
   5.4 Materials
   5.5 Cleaning and disinfecting
   5.6 Mass
   5.7 Connections
        5.7.1 General
        5.7.2 Couplings (if fitted)
        5.7.3 Strength of connections to half mask, demand
               valve and breathing hose (if fitted)
        5.7.4 Connection between apparatus and half mask
        5.7.5 High, medium and low pressure connections
   5.8 Half mask
   5.9 Body harness
   5.10 Practical performance
   5.11 Resistance to temperature and flammability
        5.11.1 Temperature performance
        5.11.2 Flammability
   5.12 Protection against particulate matter
   5.13 High and medium pressure parts
   5.14 Pressure vessel
   5.15 Pressure vessel valve(s)
   5.16 Pressure reducer
        5.16.1 General
        5.16.2 Apparatus with a pressure reducer safety
               valve
        5.16.3 Apparatus without a pressure reducer safety
               valve
   5.17 Pressure indicator and tube
        5.17.1 General
        5.17.2 Pressure indicator of the pointer type
        5.17.3 Pressure indicator of the tactile type
        5.17.4 Electronic pressure indicator
   5.18 Warning device
        5.18.1 General
        5.18.2 Pneumatic warning device
        5.18.3 Electronic warning device
   5.19 Flexible hoses and tubes
        5.19.1 Breathing hose
        5.19.2 Medium pressure connecting tube
   5.20 Lung governed demand valve
        5.20.1 General
        5.20.2 Leaktightness
   5.21 Breathing resistance
        5.21.1 Inhalation resistance
        5.21.2 Exhalation resistance
   5.22 Static pressure
6 Testing
   6.1 General
   6.2 Nominal values and tolerances
   6.3 Visual inspection
   6.4 Resistance to temperature and flammability
        6.4.1 Laboratory tests with a breathing machine
        6.4.2 Practical performance test
   6.5 Pressure reducer
        6.5.1 General
        6.5.2 Apparatus with a pressure reducer safety
               valve
        6.5.3 Apparatus without a pressure reducer safety
               valve
   6.6 Warning device
   6.7 Leaktightness
        6.7.1 Low pressure test
        6.7.2 High pressure test
   6.8 Water immersion
   6.9 Strength of connections to half mask, demand valve
        and breathing hose (if fitted)
   6.10 Resistance to collapse of breathing hose
        6.10.1 Principle
        6.10.2 Apparatus
        6.10.3 Procedure
   6.11 Practical performance
        6.11.1 General
        6.11.2 Walking test
        6.11.3 Work simulation test
   6.12 Breathing resistance
        6.12.1 Inhalation resistance
        6.12.2 Exhalation resistance
7 Marking
8 Information supplied by the manufacturer
Annex A (informative) Marking
Annex ZA (informative) Clauses of this European Standard
                       addressing essential requirements or other
                       provisions of EU Directives
Bibliography

Provides minimum performance requirements for self-contained open-circuit compressed air breathing apparatus with half mask designed to be used with positive pressure only.

DocumentType
Standard
Pages
25
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Current

Standards Relationship
I.S. EN 14435:2004 Identical
EN 14435:2004 Identical
NBN EN 14435 : 2004 Identical
NS EN 14435 : 1ED 2004 Identical
BS EN 14435:2004 Identical
NF EN 14435 : 2004 Identical
UNE-EN 14435:2004 Identical
NEN EN 14435 : 2004 Identical
UNI EN 14435 : 2004 Identical

EN 148-3:1999 Respiratory protective devices - Threads for facepieces - Part 3: Tread connection M 45 x 3
EN 12021:2014 Respiratory equipment - Compressed gases for breathing apparatus
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
EN 132:1998 Respiratory protective devices - Definitions of terms and pictograms
EN 13274-3:2001 Respiratory protective devices - Methods of test - Part 3: Determination of breathing resistance
EN 134:1998 Respiratory protective devices - Nomenclature of components
EN 13274-4:2001 Respiratory protective devices - Methods of test - Part 4: Flame tests
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
EN 140:1998/AC:1999 Respiratory protective devices - Half masks and quarter masks - Requirements, testing, marking
EN 837-1:1996/AC:1998 PRESSURE GAUGES - BOURDON TUBE PRESSURE GAUGES - DIMENSIONS, METROLOGY, REQUIREMENTS AND TESTING
EN 148-2:1999 Respiratory protective devices - Threads for facepieces - Part 2: Centre thread connection
EN 50014:1997/A2:1999 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
EN 13274-2:2001 Respiratory protective devices - Methods of test - Part 2: Practical performance tests
EN 13274-5:2001 Respiratory protective devices - Methods of test - Part 5: Climatic conditions

View more information
US$115.16
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.