• There are no items in your cart

DIN EN 50284 : 2000

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

SPECIAL REQUIREMENTS FOR CONSTRUCTION, TEST AND MARKING OF ELECTRICAL APPARATUS OF EQUIPMENT GROUP II, CATEGORY 1 G
Superseded date

06-01-2005

Published date

01-12-2013

Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen
4 Anforderungen an Konstruktion und Aufbau
  4.1 Allgemeines
  4.2 Schutzmassnahmen gegen Zündgefahren durch
      elektrische Stromkreise
      4.2.1 Allgemeines
      4.2.2 Eigensicherheit
      4.2.3 Spezielle Vergusskapselung
      4.2.4 Kombination von zwei unabhängigen
            genormten Zündschutzarten
      4.2.5 Kombination einer genormten Zündschutzart
            mit einem Trennelement
  4.3 Metallgehäuse und zugängliche Metallteile
      4.3.1 Schlag- und Reibfunken durch Metalle
      4.3.2 Isolierte Metallteile
  4.4 Nichtmetallische Gehäuse und zugängliche
      nichtmetallische Teile
      4.4.1 Allgemeines
  4.5 Mechanische Anschlüsse
5 Typprüfungen
  5.1 Genormte Zündschutzarten
  5.2 Trennelemente
6 Kennzeichnung
  6.1 Allgemeines
  6.2 Betriebsmittel oder zugehörige Betriebsmittel
      mit der Zündschutzart "Eigensicherheit" nach
      EN 50020
  6.3 Betriebsmittel mit "Spezieller Vergusskapselung"
      nach 4.2.3
  6.4 Betriebsmittel mit zwei unabhängigen
      Zündschutzarten nach 4.2.4
  6.5 Betriebsmittel, die nach 4.2.5 in die Wand zum
      gefährdeten Bereich mit Kategorie-1-Anforderungen
      montiert sind
7 Informationen zum Gebrauch

Defines the particular requirements for constructing, testing and marking electrical apparatus of equipment group II, conformity category 1 G as specified in EN 50014(1997). Consists of equipment designed for capability of functioning to conform with the operational parameters established by the manufacturer and ensuring a very high level of protection.

DocumentType
Standard
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

Standards Relationship
BS EN 50284:1999 Identical
UNE-EN 50284:2000 Identical
SN EN 50284 : 1999 Identical
NBN EN 50284 : 1ED 2000 Identical
VDE 0170-12-1 : 2015 Corresponds
I.S. EN 50284:1999 Identical
NF EN 50284 : 2000 Identical
EN 50284:1999 Identical
NEN EN 50284 : 1999 Identical

EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 50039:1980 Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i'
DIN EN 50017 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - POWDER FILLING 'Q'
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
DIN VDE 0470-1 : 1992
EN 50017:1998 Electrical apparatus for potentially explosive atmospheres - Powder filling "q"
EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
VDE 0170-6 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
EN 50018 : 2000 AMD 1 2002 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"
DIN EN 50039 : 1982 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSICALLY SAFE ELECTRICAL SYSTEMS "I"
VDE 0170-5 : 2015-04 EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' (IEC 60079-1:2014)
DIN EN 50019 : 2001 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
DIN VDE 0170/0171-9 : 1988 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES; ENCAPSULATION "M"
VDE 0170-7 : 2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I" (IEC 60079-11:2011 + COR.:2012)
VDE 0170/0171-10 : 1982 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSICALLY SAFE ELECTRICAL SYSTEMS "I"
ISO 1210:1992 Plastics — Determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source
VDE 0170/0171-3 : 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - PRESSURIZED APPARATUS "P"
DIN EN 50014 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS
VDE 0170-4 : 2015 Rotating electrical machines Part 22: AC generators for reciprocating internal combustion (RIC) engine driven generating sets
VDE 0170-1 : 2014 EXPLOSIONSGEFAEHRDETE BEREICHE - TEIL 0: BETRIEBSMITTEL - ALLGEMEINE ANFORDERUNGEN (IEC 60079-0:2011, MODIFIZIERT +COR.:2012+COR.:2013)
VDE 0170-2 : 2016 EXPLOSIVE ATMOSPHERES - PART 6: EQUIPMENT PROTECTION BY LIQUID IMMERSION 'O' (IEC 60079-6:2015)
DIN EN 50020 : 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSIC SAFETY 'I'
DIN EN 50015 : 2000 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - OIL IMMERSION 'O'
EN 50015:1998 Electrical apparatus for potentially explosive atmospheres - Oil immersion "o"
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50016:2002 Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p"
EN 50028:1987 Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm'
VDE 0170-9 : 2015 EXPLOSIVE ATMOSPHERES - PART 18: EQUIPMENT PROTECTION BY ENCAPSULATION 'M' (IEC 60079-18:2014)
EN 50014:1997/A2:1999 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS
DIN EN 50018 : 2001 AMD 1 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"

View more information
Sorry this product is not available in your region.