DIN EN ISO 4064-2:2017-10
Current
The latest, up-to-date edition.
WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014)
Hardcopy , PDF
English
01-01-2017
National foreword
National Annex NA (informative) - Bibliography
European foreword
Annex ZA (informative) - Relationship between this European
Standard and the essential requirements
of Directive 2014/32/EU aimed to be covered
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Reference conditions
5 Symbols, units and equations
6 External examination
7 Performance tests for all water meters
8 Performance tests related to influence factors and
disturbances
9 Test program for type evaluation
10 Tests for initial verification
11 Presentation of results
Annex A (normative) - Type examination and testing of
checking facilities of electronic devices
Annex B (normative) - Calculating the relative error (of
indication) of a water meter
Annex C (normative) - Installation requirements for flow
disturbance tests
Annex D (normative) - Type evaluation of a family of water
meters
Annex E (informative) - Examples of methods and components
used for testing concentric water meters
Annex F (informative) - Determining the density of water
Annex G (informative) - Maximum uncertainties in the
measurement of influence factors and disturbances
Annex H (informative) - Pressure loss test pressure
tappings, hole and slot details
Annex I (normative) - Flow disturbers
Bibliography
Describe to the type evaluation and initial verification testing of water meters for cold potable water and hot water as defined in ISO 4064-1:2014¦OIML R 49-1:2013.
DevelopmentNote |
Supersedes DIN EN 14154-3 E. (11/2014)
|
DocumentType |
Standard
|
Pages |
116
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Current
|
Standards | Relationship |
ISO 4064-2:2014 | Identical |
EN ISO 4064-2:2017 | Identical |
DIN EN ISO 4064-1:2017-10 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014) |
DIN EN 60068-2-2 : 1995 | ENVIRONMENTAL TESTING - PART 2-2: TESTS - TEST B: DRY HEAT |
DIN EN 61000-4-11 : 2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS |
ISO 7005-2:1988 | Metallic flanges — Part 2: Cast iron flanges |
VDE 0468-2-1 : 2008 | ENVIRONMENTAL TESTING - PART 2-1: TESTS - TEST A: COLD |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
IEC 60068-3-1:2011 | Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
VDE 0847-4-6 : 2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
DIN EN 60068-2-64 : 1995 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
DIN EN 61000-6-1 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
VDE 0468-1 : 2015 | Environmental testing Part 1: General and guidance (IEC 60068-1:2013) |
VDE 0847-4-5 : 2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST (IEC 61000-4-5:2014) |
IEC 61000-6-1 : 3.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
ISO 7005-3:1988 | Metallic flanges Part 3: Copper alloy and composite flanges |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
DIN EN 61000-4-5 : 2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-5: TESTING AND MEASUREMENT TECHNIQUES - SURGE IMMUNITY TEST (IEC 61000-4-5:2014) |
VDE 0847-4-2 : 2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-2: TESTING AND MEASUREMENT TECHNIQUES - ELECTROSTATIC DISCHARGE IMMUNITY TEST |
VDE 0468-3-1 : 2012-04 | UMGEBUNGSEINFLUESSE - TEIL 3-1: UNTERSTUETZENDE DOKUMENTATION UND LEITFADEN - PRUEFVERFAHREN KAELTE UND TROCKENE WAERME (IEC 60068-3-1:2011) |
VDE 0839-6-1 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS |
DIN EN ISO 4064-3 E : 2014 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST REPORT FORMAT (ISO 4064-3:2014) |
VDE 0847-4-11 : 2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS |
VDE 0839-6-2 : 2006 COR 1 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - GENERIC STANDARDS; IMMUNITY FOR INDUSTRIAL ENVIRONMENTS |
DIN EN 61000-4-4 : 2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
ISO 4064-3:2014 | Water meters for cold potable water and hot water — Part 3: Test report format |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
DIN EN 60068-2-30:2006-06 | ENVIRONMENTAL TESTING - PART 2-30: TESTS - TEST DB: DAMP HEAT, CYCLIC (12 H + 12 H CYCLE) |
OIML B 3 : 2011 | OIML BASIC CERTIFICATE SYSTEM FOR OIML TYPE EVALUATION OF MEASURING INSTRUMENTS |
VDE 0468-2-2 : 2008 | ENVIRONMENTAL TESTING - PART 2-2: TESTS - TEST B: DRY HEAT |
IEC 61000-4-6 : 4.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS |
VDE 0847-4-1 : 2007 | |
DIN EN 60068-2-1 : 1995 | ENVIRONMENTAL TESTING - PART 2-1: TESTS - TEST A: COLD |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
VDE 0847-4-4 : 2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
DIN EN 61000-2-2 : 2003 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-2: ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS |
VDE 0468-2-31 : 2009 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
DIN EN 60068-1 : 2015 | ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE (IEC 60068-1:2013) |
DIN EN 61000-4-6 : 2014 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
DIN EN 61000-4-3 : 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
DIN EN 61000-4-1 : 2007 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-1: TESTING AND MEASUREMENT TECHNIQUES - OVERVIEW OF IEC 61000-4 SERIES |
DIN EN 60068-2-47:2006-03 | ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS |
VDE 0839-2-2 : 2003 | ELEKTROMAGNETISCHE VERTRAEGLICHKEIT (EMV) - UMGEBUNGSBEDINGUNGEN - VERTRAEGLICHKEITSPEGEL FUER NIEDERFREQUENTE LEITUNGSGEFUEHRTE STOERGROESSEN UND SIGNALUEBERTRAGUNG IN OEFFENTLICHEN NIEDERSPANNUNGSNETZEN |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 61000-6-1:2016 | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments |
ISO 286-2:2010 | Geometrical product specifications (GPS) ISO code system for tolerances on linear sizes Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts |
DIN EN ISO 4064-1:2017-10 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS (ISO 4064-1:2014) |
DIN EN 60654-2:1998-08 | OPERATING CONDITIONS FOR INDUSTRIAL-PROCESS MEASUREMENT AND CONTROL EQUIPMENT - PART 2: POWER |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-3-4:2001 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
DIN EN 60068-3-4:2002-11 | ENVIRONMENTAL TESTING - PART 3-4: SUPPORTING DOCUMENTATION AND GUIDANCE; DAMP HEAT TESTS |
DIN EN 61000-4-2 : 2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-2: TESTING AND MEASUREMENT TECHNIQUES - ELECTROSTATIC DISCHARGE IMMUNITY TEST |
VDE 0847-4-3 : 2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
VDE 0468-2-64 : 2009 | ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE |
DIN EN 60068-2-31 : 2009 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
ISO 4064-1:2014 | Water meters for cold potable water and hot water Part 1: Metrological and technical requirements |
IEC 61000-6-2 : 3.0:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS |
DIN EN 60068-3-1 : 2012-04 | ENVIRONMENTAL TESTING - PART 3-1: SUPPORTING DOCUMENTATION AND GUIDANCE - COLD AND DRY HEAT TESTS (IEC 60068-3-1:2011) |
ISO 228-1:2000 | Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.