EN 13565-2:2009/AC:2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
02-22-2022
01-12-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Foam extinguishing systems
4.1 General
4.1.1 General requirements
4.1.2 Environmental considerations
4.1.3 Planning
4.1.4 Documentation
4.1.5 Supplementary manual foam fire fighting
provisions
4.1.6 Equipment
4.2 Water supply
4.2.1 Water demand
4.2.2 Operating time
4.2.3 Quality of water
4.2.4 Power supply for water pumps
4.3 Foam concentrate
4.3.1 General
4.3.2 Foam concentrate supply - low and medium
expansion foams
4.3.3 Foam concentrate pumps
4.3.4 Supplementary external connections
4.4 Foam proportioners
4.5 Pipework
4.5.1 Water and foam solution pipework
4.5.2 Foam concentrate piping
4.5.3 Non Newtonian foam concentrate
4.5.4 Piping of aspirated foam (including that for
subsurface foam applications)
4.5.5 Marking
4.6 Foam discharge outlets and generators
4.7 Operation and control systems
4.7.1 Detection of fires
4.7.2 Release of fixed foam extinguishing systems
4.7.3 Alarms
5 Design
5.1 Application rates
5.2 Flammable liquid storage tanks, bunds and process
areas
5.2.1 General
5.2.2 Number of foam discharge outlets
5.2.3 Fixed cone roof tanks
5.2.4 Floating roof tanks
5.2.5 Bunded/diked areas and process areas
6 Foam sprinkler and deluge systems
6.1 Deluge systems
6.1.1 Deluge applications
6.1.2 Deluge limitations
6.1.3 Deluge design
6.2 Foam enhanced sprinkler systems
6.2.1 Foam enhanced sprinkler applications
6.2.2 Foam enhanced sprinkler limitations
6.2.3 Foam enhanced sprinkler design
6.3 Foam concentrate
6.3.1 Aspirated foams
6.3.2 Non aspirated foams
6.4 Foam proportioning
6.5 Drain and flushing connections
7 High expansion foam systems
7.1 General
7.2 Foam concentrate
7.3 Equipment
7.4 System design
7.5 Equipment location considerations
7.6 Personnel safety
7.7 Discharge rate (total flooding systems)
7.8 Discharge time (total flooding systems)
8 Marine loading and unloading docks
8.1 Water supplies
8.2 Foam concentrate
8.3 Foam water monitors
8.4 Below dock foam systems
9 Aircraft hangars
9.1 General
9.2 Hangar partitioning
9.3 Fire detection
9.4 System design philosophy
9.5 System duration
9.6 Foam and water pumps
9.7 Acceptable application methods
9.8 Foam types
9.9 Monitors
9.10 Foam-water deluge systems
9.11 Medium expansion systems (Type 3 hangars only)
9.12 High expansion systems
9.13 Headlines
9.14 Commissioning tests
10 Liquefied flammable gases (LNG/LPG)
10.1 General
10.1.1 Liquefied Natural Gas (LNG)
10.1.2 Liquefied Petroleum Gas (LPG)
10.2 Controlled burn-off
10.3 Un-ignited spills
10.4 Fire detection
10.5 Foam properties
10.6 Foam proportioning system
10.7 Application techniques
11 Commissioning, testing, and periodic inspections
11.1 Instruction of operating personnel
11.2 Commissioning
11.2.1 General
11.2.2 Visual inspection
11.2.3 Pressure tests
11.2.4 Tests
11.2.5 Completion certificate
11.3 The periodic inspection and testing of foam systems
11.3.1 General
11.3.2 Inspections
11.4 Shut-down
11.5 Maintenance
11.6 Alterations
Bibliography
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.