Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows
Superseded date

03-17-2022

Published date

01-15-2014

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
5 Test conditions
6 Test specimen
7 Installation of test specimen
8 Conditioning
9 Application of instrumentation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (normative) - Conditioning requirements
Annex B (normative) - Field of direct application
        limits of permitted size variations
Annex C (informative) - Background to field of
        direct application statements for asymmetric
        constructions and supporting constructions
Bibliography

This European Standard specifies a method for determining the fire resistance of door and shutter assemblies and openable windows designed for installation within openings incorporated in vertical separating elements, such as:a)hinged and pivoted doors;b)horizontally sliding and vertically sliding doors including articulated sliding doors and sectional doors;c)folding doors, sliding folding doors /shutters;d)tilting doors;e)rolling shutter doors;f)openable windows;g)operable fabric curtains.This European Standard is used in conjunction with EN 1363 1.The testing of fire dampers is covered by EN 1366 2.The testing of closures for conveyor systems is covered by EN 1366 7.By prior agreement with the test sponsor, additional information may be gained for individual elements of building hardware in order to fulfil the performance criteria identified in EN 1634 2. Based on the observations recorded during the test, the results may be presented in a separate report which should be in accordance with the requirements of EN 1634 2.

Committee
CEN/TC 127
DevelopmentNote
To be read in conjunction with EN 1363-1. (05/2009) 2014 Edition Re-Issued in January 2018 & incorporates AMD 1 2018. (02/2018)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1634-2 : 2008 Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
EN 12519:2004 Windows and pedestrian doors - Terminology
EN 1366-7:2004 Fire resistance tests for service installations - Part 7: Conveyor systems and their closures
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 1366-2:2015 Fire resistance tests for service installations - Part 2: Fire dampers
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.