• There are no items in your cart

EN 4618:2009

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Aerospace series - Aircraft internal air quality standards, criteria and determination methods

Withdrawn date

03-31-2010

Published date

09-16-2009

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Air quality
5 Environmental criteria
Annex A (informative) - Altitude corrections for volume
                        concentrations
Annex B (informative) - Bacteria, fungi and viruses
Annex C (informative) - Technical information for bacteria,
                        viruses and other particulate
                        contamination removal
Annex D (informative) - Measurement method for micro-organisms
Annex E (informative) - Operative temperature and air velocity
                        ranges

This standard specifies requirements and determination methods for newly certificated commercial passenger aircraft programmes.This standard applies to newly certificated commercial passenger aircraft programmes. It may also apply to current production aircraft if it does not carry significant penalties, i.e. if it can be shown to be technically feasible and economically justifiable.This standard covers the period from first crew embarkation to last crew disembarkation.NOTE 1During embarkation and disembarkation, reduced temperatures in the cabin may be desirable due to increased metabolic activity of the occupants. In some ground cases, the aircraft environmental control system (ECS) may not be able to compensate for the external conditions influencing the cabin comfort conditions, such as open doors, extreme hot/cold ground/air temperatures or radiant heat. In this case, external air-conditioning systems, for example conditioned low-pressure ground air or high-pressure supply, may be used to supplement the aircraft ECS. If the temperature range stated in this standard is regularly exceeded (either above or below the stated range), changes to airline and/or airport procedures and/or aircraft design should be introduced.NOTE 2During ground operations, the external air quality may adversely influence the air quality within the aircraft cabin. Contamination produced as a result of servicing activities or ground operations vehicles may enter the aircraft directly, for example via open doors, and the ECS may not be able to effectively control contaminant levels in the cabin. Airline and airport operational procedures should be organised so as to avoid direct contamination of the cabin from these pollutant sources. If the contaminant ranges stated in this standard are regularly exceeded, changes to airline and/or airport procedures and/or aircraft design should be introduced.Outside air quality levels would usually be regulated by national authorities.(...)

Committee
ASD-STAN
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
DIN EN 4618:2010-01 Identical
NF EN 4618 : 2010 Identical
NS EN 4618 : 2009 Identical
UNE-EN 4618:2009 Identical
NEN EN 4618 : 2009 Identical
BS EN 4618:2009 Identical
SN EN 4618:2010 Identical
PN EN 4618 : 2009 Identical
NBN EN 4618 : 2009 Identical
I.S. EN 4618:2009 Identical

13/30280751 DC : 0 BS EN 4666 - AEROSPACE SERIES - AIRCRAFT INTEGRATED AIR QUALITY AND PRESSURE STANDARDS, CRITERIA AND DETERMINATION METHODS
TR 4666 : 2016 AEROSPACE SERIES - AIRCRAFT INTEGRATED AIR QUALITY AND PRESSURE STANDARDS, CRITERIA AND DETERMINATION METHODS

SAE AIR 4766 : 2012 AIR QUALITY FOR COMMERCIAL AIRCRAFT CABINS
EN 481:1993 Workplace atmospheres - Size fraction definitions for measurement of airborne particles
EN ISO 16017-1:2000 Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000)
ISO 7726:1998 Ergonomics of the thermal environment Instruments for measuring physical quantities
ISO 16017-1:2000 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling
EN 14181:2014 Stationary source emissions - Quality assurance of automated measuring systems
EN ISO 7730:2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria (ISO 7730:2005)
ASTM D 6699 : 2016 : REDLINE Standard Practice for Sampling Liquids Using Bailers
ISO 7730:2005 Ergonomics of the thermal environment — Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria
ASTM D 6399 : 2010-07 GUIDE FOR SELECTING INSTRUMENTS AND METHODS FOR MEASURING AIR QUALITY IN AIRCRAFT CABINS
ISO 16000-3:2011 Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method
ISO 16000-6:2011 Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.