EN 50284:1999

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Special requirements for construction, test and marking of electrical apparatus of equipment group II, Category 1 G
Superseded date

12-01-2004

Published date

04-28-1999

Foreword
1 Scope
2 Normative references
3 Definitions
4 Requirements for design and construction
5 Type tests
6 Marking
7 Information for use

This European Standard specifies the particular requirements for construction, testing and marking of electrical apparatus of equipment group II, conformity Category 1 G as defined in EN 50014:1997. Such apparatus comprises equipment designed to be capable of functioning in conformity with the operational parameters established by the manufacturer and ensuring a very high level of protection. Category 1 G apparatus is intended for use in hazardous areas, in which potentially explosive atmospheres caused by mixtures of air and gases, vapours or mists under normal atmospheric conditions (temperature = -20 °C to +60 °C, pressure = 0,8 bar to 1,1 bar) are present continuously, for long periods or frequently. This standard also applies to apparatus mounted across the boundary between hazardous and less hazardous areas where Category 1 and Category 2 equipment may normally be installed, respectively, for example in the wall of a storage vessel. This standard also makes provision for apparatus installed outside the hazardous area, but electrically connected to apparatus of Category 1 within the hazardous area (associated apparatus).This standard supplements the requirements of EN 50014 to EN 50020 and EN 50028 to adapt the level of safety provided by those standards to the very high level of risk. NOTE: In designing apparatus for operation in a potentially explosive atmosphere under conditions other than the atmospheric conditions given above, this standard may be used as a guide. However, additional testing is recommended related specifically to the intended conditions of use. This is particularly important when the types of protection Flameproof enclosure (EN 50018) and Intrinsic safety (EN 50020) are applied

Committee
CLC/TC 31
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

Standards Relationship
SN EN 50284 : 1999 Identical
NBN EN 50284 : 1ED 2000 Identical
I.S. EN 50284:1999 Identical
NF EN 50284 : 2000 Identical
BS EN 50284:1999 Identical
VDE 0170-12-1 : 2015 Identical
UNE-EN 50284:2000 Identical
DIN EN 50284 : 2000 Identical
NEN EN 50284 : 1999 Identical
CEI EN 50284 : 2012 Identical

I.S. EN 50020:2002 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSIC SAFETY "I"
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
BS EN 50020:2002 Electrical apparatus for potentially explosive atmospheres. Intrinsic safety \'i\'

EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 50039:1980 Electrical apparatus for potentially explosive atmospheres - Intrinsically safe electrical systems 'i'
EN 50020:2002 Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i'
EN 50017:1998 Electrical apparatus for potentially explosive atmospheres - Powder filling "q"
EN 50019:2000/corrigendum Apr. 2003 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E"
EN 50018 : 2000 AMD 1 2002 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D"
ISO 1210:1992 Plastics — Determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source
EN 50015:1998 Electrical apparatus for potentially explosive atmospheres - Oil immersion "o"
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50016:2002 Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p"
EN 50028:1987 Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm'
EN 50014:1997/A2:1999 ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.